Literature DB >> 24719050

An in vitro evaluation of the impact of eccentric deployment on transcatheter aortic valve hemodynamics.

Paul S Gunning1, Neelakantan Saikrishnan, Laoise M McNamara, Ajit P Yoganathan.   

Abstract

Patients with aortic stenosis present with calcium deposits on the native aortic valve, which can result in non-concentric expansion of Transcatheter Aortic Valve Replacement (TAVR) stents. The objective of this study is to evaluate whether eccentric deployment of TAVRs lead to turbulent blood flow and blood cell damage. Particle Image Velocimetry was used to quantitatively characterize fluid velocity fields, shear stress and turbulent kinetic energy downstream of TAVRs deployed in circular and eccentric orifices representative of deployed TAVRs in vivo. Effective orifice area (EOA) and mean transvalvular pressure gradient (TVG) values did not differ substantially in circular and eccentric deployed valves, with only a minor decrease in EOA observed in the eccentric valve (2.0 cm(2) for circular, 1.9 cm(2) for eccentric). Eccentric deployed TAVR lead to asymmetric systolic jet formation, with increased shear stresses (circular = 97 N/m(2) vs. eccentric = 119 N/m(2)) and regions of turbulence intensity (circular = 180 N/m(2) vs. eccentric = 230 N/m(2)) downstream that was not present in the circular deployed TAVR. The results of this study indicate that eccentric deployment of TAVRs can lead to altered flow characteristics and may potentially increase the hemolytic potential of the valve, which were not captured through hemodynamic evaluation alone.

Entities:  

Mesh:

Year:  2014        PMID: 24719050     DOI: 10.1007/s10439-014-1008-6

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  23 in total

1.  In vitro hemodynamic assessment of a novel polymeric transcatheter aortic valve.

Authors:  Megan Heitkemper; Hoda Hatoum; Lakshmi Prasad Dasi
Journal:  J Mech Behav Biomed Mater       Date:  2019-06-19

2.  Realistic Vascular Replicator for TAVR Procedures.

Authors:  Oren M Rotman; Brandon Kovarovic; Chander Sadasivan; Luis Gruberg; Baruch B Lieber; Danny Bluestein
Journal:  Cardiovasc Eng Technol       Date:  2018-04-13       Impact factor: 2.495

3.  A mechanistic investigation of the EDWARDS INTUITY Elite valve's hemodynamic performance.

Authors:  Vahid Sadri; Charles H Bloodworth; Immanuel David Madukauwa-David; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Gen Thorac Cardiovasc Surg       Date:  2019-06-27

Review 4.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

Review 5.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

6.  Fetal Transcatheter Trileaflet Heart Valve Hemodynamics: Implications of Scaling on Valve Mechanics and Turbulence.

Authors:  Hoda Hatoum; Shelley Gooden; Megan Heitkemper; Kevin M Blum; Jason Zakko; Martin Bocks; Tai Yi; Yen-Lin Wu; Yadong Wang; Christopher K Breuer; Lakshmi Prasad Dasi
Journal:  Ann Biomed Eng       Date:  2020-02-12       Impact factor: 3.934

7.  Stented valve dynamic behavior induced by polyester fiber leaflet material in transcatheter aortic valve devices.

Authors:  Hoda Hatoum; Frederick Heim; Lakshmi Prasad Dasi
Journal:  J Mech Behav Biomed Mater       Date:  2018-06-28

8.  Quantification of thrombus formation in malapposed coronary stents deployed in vitro through imaging analysis.

Authors:  Jonathan Brown; Caroline C O'Brien; Augusto C Lopes; Kumaran Kolandaivelu; Elazer R Edelman
Journal:  J Biomech       Date:  2018-02-09       Impact factor: 2.712

9.  Simulated Transcatheter Aortic Valve Flow: Implications of Elliptical Deployment and Under-Expansion at the Aortic Annulus.

Authors:  Eric Sirois; Wenbin Mao; Kewei Li; Joseph Calderan; Wei Sun
Journal:  Artif Organs       Date:  2018-04-02       Impact factor: 3.094

10.  Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement.

Authors:  Paul S Gunning; Neelakantan Saikrishnan; Ajit P Yoganathan; Laoise M McNamara
Journal:  J R Soc Interface       Date:  2015-12-06       Impact factor: 4.118

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.