Literature DB >> 16985271

An enhanced block matching algorithm for fast elastic registration in adaptive radiotherapy.

U Malsch1, C Thieke, P E Huber, R Bendl.   

Abstract

Image registration has many medical applications in diagnosis, therapy planning and therapy. Especially for time-adaptive radiotherapy, an efficient and accurate elastic registration of images acquired for treatment planning, and at the time of the actual treatment, is highly desirable. Therefore, we developed a fully automatic and fast block matching algorithm which identifies a set of anatomical landmarks in a 3D CT dataset and relocates them in another CT dataset by maximization of local correlation coefficients in the frequency domain. To transform the complete dataset, a smooth interpolation between the landmarks is calculated by modified thin-plate splines with local impact. The concept of the algorithm allows separate processing of image discontinuities like temporally changing air cavities in the intestinal track or rectum. The result is a fully transformed 3D planning dataset (planning CT as well as delineations of tumour and organs at risk) to a verification CT, allowing evaluation and, if necessary, changes of the treatment plan based on the current patient anatomy without time-consuming manual re-contouring. Typically the total calculation time is less than 5 min, which allows the use of the registration tool between acquiring the verification images and delivering the dose fraction for online corrections. We present verifications of the algorithm for five different patient datasets with different tumour locations (prostate, paraspinal and head-and-neck) by comparing the results with manually selected landmarks, visual assessment and consistency testing. It turns out that the mean error of the registration is better than the voxel resolution (2 x 2 x 3 mm(3)). In conclusion, we present an algorithm for fully automatic elastic image registration that is precise and fast enough for online corrections in an adaptive fractionated radiation treatment course.

Entities:  

Mesh:

Year:  2006        PMID: 16985271     DOI: 10.1088/0031-9155/51/19/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Assessment of dose reconstruction errors in image-guided radiation therapy.

Authors:  Hualiang Zhong; Elisabeth Weiss; Jeffrey V Siebers
Journal:  Phys Med Biol       Date:  2008-01-11       Impact factor: 3.609

2.  Objective assessment of deformable image registration in radiotherapy: a multi-institution study.

Authors:  Rojano Kashani; Martina Hub; James M Balter; Marc L Kessler; Lei Dong; Lifei Zhang; Lei Xing; Yaoqin Xie; David Hawkes; Julia A Schnabel; Jamie McClelland; Sarang Joshi; Quan Chen; Weiguo Lu
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

3.  Feature-based rectal contour propagation from planning CT to cone beam CT.

Authors:  Yaoqin Xie; Ming Chao; Percy Lee; Lei Xing
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

4.  Technical note: deformable image registration on partially matched images for radiotherapy applications.

Authors:  Deshan Yang; S Murty Goddu; Wei Lu; Olga L Pechenaya; Yu Wu; Joseph O Deasy; Issam El Naqa; Daniel A Low
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

5.  Automatic multiorgan segmentation in CT images of the male pelvis using region-specific hierarchical appearance cluster models.

Authors:  Dengwang Li; Pengxiao Zang; Xiangfei Chai; Yi Cui; Ruijiang Li; Lei Xing
Journal:  Med Phys       Date:  2016-10       Impact factor: 4.071

6.  Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study.

Authors:  M A Deeley; A Chen; R Datteri; J H Noble; A J Cmelak; E F Donnelly; A W Malcolm; L Moretti; J Jaboin; K Niermann; Eddy S Yang; David S Yu; F Yei; T Koyama; G X Ding; B M Dawant
Journal:  Phys Med Biol       Date:  2011-07-01       Impact factor: 3.609

7.  Computing global minimizers to a constrained B-spline image registration problem from optimal l1 perturbations to block match data.

Authors:  Edward Castillo; Richard Castillo; David Fuentes; Thomas Guerrero
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

8.  Learning statistical correlation for fast prostate registration in image-guided radiotherapy.

Authors:  Yonghong Shi; Shu Liao; Dinggang Shen
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

9.  Deformable mesh registration for the validation of automatic target localization algorithms.

Authors:  Scott Robertson; Elisabeth Weiss; Geoffrey D Hugo
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

10.  Validation of deformable registration in head and neck cancer using analysis of variance.

Authors:  A Mencarelli; S van Beek; S van Kranen; C Rasch; M van Herk; J-J Sonke
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.