Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position.

Thomas G Purdie1, Jean-Pierre Bissonnette, Kevin Franks, Andrea Bezjak, David Payne, Fanny Sie, Michael B Sharpe, David A Jaffray.   

Abstract

PURPOSE: Cone-beam computed tomography (CBCT) in-room imaging allows accurate inter- and intrafraction target localization in stereotactic body radiotherapy of lung tumors. METHODS AND MATERIALS: Image-guided stereotactic body radiotherapy was performed in 28 patients (89 fractions) with medically inoperable Stage T1-T2 non-small-cell lung carcinoma. The targets from the CBCT and planning data set (helical or four-dimensional CT) were matched on-line to determine the couch shift required for target localization. Matching based on the bony anatomy was also performed retrospectively. Verification of target localization was done using either megavoltage portal imaging or CBCT imaging; repeat CBCT imaging was used to assess the intrafraction tumor position.
RESULTS: The mean three-dimensional tumor motion for patients with upper lesions (n = 21) and mid-lobe or lower lobe lesions (n = 7) was 4.2 and 6.7 mm, respectively. The mean difference between the target and bony anatomy matching using CBCT was 6.8 mm (SD, 4.9, maximum, 30.3); the difference exceeded 13.9 mm in 10% of the treatment fractions. The mean residual error after target localization using CBCT imaging was 1.9 mm (SD, 1.1, maximum, 4.4). The mean intrafraction tumor deviation was significantly greater (5.3 mm vs. 2.2 mm) when the interval between localization and repeat CBCT imaging (n = 8) exceeded 34 min.
CONCLUSION: In-room volumetric imaging, such as CBCT, is essential for target localization accuracy in lung stereotactic body radiotherapy. Imaging that relies on bony anatomy as a surrogate of the target may provide erroneous results in both localization and verification.

Entities:  

Mesh:

Year:  2007        PMID: 17331671     DOI: 10.1016/j.ijrobp.2006.12.022

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  100 in total

1.  Localization accuracy of the clinical target volume during image-guided radiotherapy of lung cancer.

Authors:  Geoffrey D Hugo; Elisabeth Weiss; Ahmed Badawi; Matthew Orton
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-01-27       Impact factor: 7.038

2.  Localization accuracy from automatic and semi-automatic rigid registration of locally-advanced lung cancer targets during image-guided radiation therapy.

Authors:  Scott P Robertson; Elisabeth Weiss; Geoffrey D Hugo
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

3.  Dosimetric effects of roll rotational setup errors on lung stereotactic ablative radiotherapy using volumetric modulated arc therapy.

Authors:  Jaegi Lee; Jung-In Kim; Sung-Joon Ye; Hak Jae Kim; Joel Carlson; Jong Min Park
Journal:  Br J Radiol       Date:  2015-09-15       Impact factor: 3.039

4.  Quality and accuracy of cone beam computed tomography gated by active breathing control.

Authors:  Bria P Thompson; Geoffrey D Hugo
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

Review 5.  kV cone-beam CT-based IGRT: a clinical review.

Authors:  Judit Boda-Heggemann; Frank Lohr; Frederik Wenz; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

6.  Registration of clinical volumes to beams-eye-view images for real-time tracking.

Authors:  Jonathan H Bryant; Joerg Rottmann; John H Lewis; Pankaj Mishra; Paul J Keall; Ross I Berbeco
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

7.  Evaluation of Elekta 4D cone beam CT-based automatic image registration for radiation treatment of lung cancer.

Authors:  Jun Li; Amy Harrison; Yan Yu; Ying Xiao; Maria Werner-Wasik; Bo Lu
Journal:  Br J Radiol       Date:  2015-07-17       Impact factor: 3.039

8.  Interobserver variability of patient positioning using four different CT datasets for image registration in lung stereotactic body radiotherapy.

Authors:  Markus Oechsner; Barbara Chizzali; Michal Devecka; Stefan Münch; Stephanie Elisabeth Combs; Jan Jakob Wilkens; Marciana Nona Duma
Journal:  Strahlenther Onkol       Date:  2017-07-19       Impact factor: 3.621

9.  Technical note: improved positioning protocol for patient setup accuracy in conventional radiotherapy for lung cancer.

Authors:  Hongbo Chai; Yuichiro Narita; Masafumi Takagi; Mikiko Kudo; Tomomi Kimura; Keiichi Kattou
Journal:  Radiol Phys Technol       Date:  2019-09-23

10.  Impact of residual and intrafractional errors on strategy of correction for image-guided accelerated partial breast irradiation.

Authors:  Gang Cai; Wei-Gang Hu; Jia-Yi Chen; Xiao-Li Yu; Zi-Qiang Pan; Zhao-Zhi Yang; Xiao-Mao Guo; Zhi-Min Shao; Guo-Liang Jiang
Journal:  Radiat Oncol       Date:  2010-10-26       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.