Mirjam Mast1, Emile Coerkamp, Mark Heijenbrok, Astrid Scholten, Wim Jansen, Erik Kouwenhoven, Jasper Nijkamp, Stephanie de Waard, Anna Petoukhova, Henk Struikmans.
Abstract
INTRODUCTION: In breast conserving radiotherapy differences of target volume delineations between observers do occur. We evaluated whether delineations based on co-registered computed tomography (CT) and magnetic resonance (MR) imaging may result in an improved consistency between observers. We used the delineation conformity index (CI) to compare clinical target volumes of glandular breast tissue (CTV breast) and lumpectomy cavity (LC) on both imaging modalities. METHODS AND MATERIALS: Four observers delineated CTV breast and LC on co-registered CTMR images in ten breast cancer patients. CIs were determined for CT and CTMR. Furthermore, the Cavity Visualization Score (CVS) of LC was taken into account.Entities:
Mesh:
Year: 2014 PMID: 24571843 PMCID: PMC3996045 DOI: 10.1186/1748-717X-9-65
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Delineation instructions for CTV Breast and the lumpectomy cavity
| Window/Level (WL); Window Width (WW) | - Fixed: WL 0 Hounsfield Unit (HU) and WW of 500 HU for CT and variable WL and WW for MRI. | - Fixed: WL 0 Hounsfield Unit (HU) and WW of 500 HU for CT and variable WL and WW for MRI. |
| - Change of WL and WW during delineation permitted for CT and MRI. | - Change of WL and WW during delineation permitted for CT and MRI. | |
| Appearance | - The location of the marking wire, positioned around the palpable Glandular Breast Tissue (GBT), will be used as an aid for CTV Breast delineation. | Appearance of contralateral breast (comparing with ipsilateral breast) serves as aid for LC delineation. |
| - The clinical target volume (CTV) breast was defined to comprise all GBT including fatty (involuted) lobes. | ||
| - Margin of the GBT is (ventrally) assumed to be situated 5 mm below the skin surface; in case of MRI the visible GBT fat is (ventrally) delineated as GBT margin. | ||
| - Delineation is performed on all CT or MRI slices that are judged to contain GBT. | ||
| - Appearance of the contralateral breast (by comparing with the ipsilateral breast) on CT or MR images. | ||
| - The preoperative mammographies and location of the palpable GBT marking wire, visible on CT or MRI, all will serve as an aid for GBT delineation. | ||
| Clips | Surgical clips (if applicable) should all be included within the delineated GBT. | All surgical clips (if applicable) should be included within delineated LC. |
| Seroma | Postoperative seroma/hematoma present in LC should be included within delineated GBT. | Postoperative seroma/hematoma present in LC should be included within delineated LC. |
Abbreviations:LC lumpectomy cavity, WL window level, WW window width, HU Hounsfield unit, MRI magnetic resonance imaging, CT computed tomography.
Conformity indices of the CTV breast and lumpectomy cavity (LC) delineations for each observer, CT compared to CTMR
| Observer_1 | 0.99 (0.01) | 0.84 (0.09) |
| Observer_2 | 0.89 (0.05) | 0.70 (0.23) |
| Observer_3 | 1.00 (0.00) | 0.91 (0.17) |
| Observer_4 | 0.97 (0.05) | 0.85 (0.30) |
Conformity indices (CI ; CI ) of the CTV breast and lumpectomy cavity (LC) delineations based on CT and CTMR for all observers
| CICT | 0.82 (0.04) | 0.52 (0.20) |
| CICTMR | 0.80 (0.06) | 0.48 (0.21) |
| p-value CICT-CTMR | 0.07 | 0.33 |
Figure 1Left: Coronal posterior view of the ten delineated Clinical Target Volume (CTV) breast Computed Tomography (CT) volumes. Right: Coronal view of the ten delineated CTV breast CTMR volumes. The local surface distance variation of the four observers is projected on the median surface of each CTV breast. Colour map: Blue: high agreement between observers; Red: low agreement between observers according to the scale given.
Mean volumes for all observers of the lumpectomy cavity (LC) delineations based on CT and CTMR
| Patient_6 | 28 | 25 |
| Patient_7 | 73 | 71 |
| Patient_8 | 14 | 13 |
| Patient_9 | 7 | 7 |
| Patient_10 | 11 | 11 |
| Patient_11 | 29 | 32 |
| Patient_12 | 4 | 9 |
| Patient_13 | 30 | 34 |
| Patient_14 | 8 | 13 |
| Patient_15 | 33 | 45 |
Figure 2For each patient for the lumpectomy cavity the Conformity Index (CI) on CT, the CI on CTMR and the Cavity Visualization Score (CVS) were determined.
Figure 3Differences between the 4 observers on co-registered CTMR images; Left: volumes delineated on CT. Right: volumes delineated on CTMR; a. Example of a patient with seroma, a CVS of 5; b. Example of a patient with a CVS of 2.
Figure 4Left: Coronal view of the ten delineated Lumpectomy Cavity (LC) CT volumes in both anterior as well as posterior view. Right: Coronal view of the ten delineated LC CTMR volumes in both anterior as well as posterior view. The local surface distance variation of the four observers is projected on the median surface of each LC. Colour map: Blue: high agreement between observers; Red: low agreement between observers according to the scale given.