| Literature DB >> 28740451 |
Noora Al-Hammadi1, Palmira Caparrotti1, Saju Divakar1, Mohamed Riyas1, Suparna Halsnad Chandramouli1, Rabih Hammoud1, Jillian Hayes1, Maeve Mc Garry1, Satheesh Prasad Paloor1, Primoz Petric1.
Abstract
BACKGROUND: Omitting the placement of clips inside tumour bed during breast cancer surgery poses a challenge for delineation of lumpectomy cavity clinical target volume (CTVLC). We aimed to quantify inter-observer variation and accuracy for CT- and MRI-based segmentation of CTVLC in patients without clips. PATIENTS AND METHODS: CT- and MRI-simulator images of 12 breast cancer patients, treated by breast conserving surgery and radiotherapy, were included in this study. Five radiation oncologists recorded the cavity visualization score (CVS) and delineated CTVLC on both modalities. Expert-consensus (EC) contours were delineated by a senior radiation oncologist, respecting opinions of all observers. Inter-observer volumetric variation and generalized conformity index (CIgen) were calculated. Deviations from EC contour were quantified by the accuracy index (AI) and inter-delineation distances (IDD).Entities:
Keywords: CT; MRI; breast cancer; contouring; contouring variation
Year: 2017 PMID: 28740451 PMCID: PMC5514656 DOI: 10.1515/raon-2017-0014
Source DB: PubMed Journal: Radiol Oncol ISSN: 1318-2099 Impact factor: 2.991
Figure 1(A) Generalized conformity index (CIgen) and (B) accuracy index (AI) as a function of the cavity visualization score (CVS) for CT and MRI based contouring of lumpectomy cavity clinical target volume. None of the patients had surgical clips inserted in the tumor bed. Case numbers are indicated for each modality.
Figure 2CT and MRI based contouring in two examples with high and low cavity visualization scores (CVS). Observers’ delineations are white and expert consensus (EC) contours black. (A) Case with a CVS of 4.8 on CT and 5 on MRI: mean generalized conformity index (CIgen), accuracy index (AI) and inter-delineation distance (IDD) were 0.79, 0.85 and 2.4 mm on CT and 0.80, 0.86 and 2.2 mm on MRI. (B) Case with a CVS of 2 on CT and 3 on MRI: mean CIgen, AI and IDD were 0.46, 0.61 and 6 mm for CT and 0.63, 0.73 and 4.5 mm for MRI.
Results for inter-observer variation in contouring. The difference in mean generalized conformity index (CIgen) between the CT and MRI based contouring was statistically significant (p = 0.007)
| Case | CT | MRI | ||||
|---|---|---|---|---|---|---|
| 198 (10) | 5 | 0.85 | 106 (4) | 4 | 0.87 | |
| 241 (37.5) | 16 | 0.69 | 256 (28) | 11 | 0.77 | |
| 108 (20.7) | 19 | 0.56 | 125 (10) | 8 | 0.75 | |
| 75 (18.1) | 24 | 0.64 | 92 (12) | 13 | 0.69 | |
| 175 (47.9) | 27 | 0.46 | 217 (68) | 31 | 0.63 | |
| 140 (10.1) | 7 | 0.76 | 125 (14) | 11 | 0.76 | |
| 103(39.7) | 39 | 0.48 | 64 (2) | 4 | 0.66 | |
| 180 (22.5) | 12 | 0.79 | 158 (14) | 9 | 0.8 | |
| 135 (19.8) | 15 | 0.77 | 126 (20) | 16 | 0.71 | |
| 204 (44.3) | 22 | 0.68 | 215 (19) | 9 | 0.76 | |
| 99 (14.4) | 15 | 0.66 | 135 (11) | 8 | 0.79 | |
| 195 (27.3) | 14 | 0.69 | 210 (29) | 14 | 0.74 | |
| 154 (26) | 18 | 0.67 (0.12) | 152 (19) | 12 | 0.74 (0.07) | |
CoV = Coefficient of Variance; CTVLC = Clinical Target Volume of Lumpectomy Cavity; SD = Standard Deviation
Accuracy index (AI) and inter-delineation distances (IDD), based on the expert consensus (EC) delineation as the reference. The differences in AI and IDD between CT and MRI were statistically significant (p < 0.05)
| CT | MRI | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Case | ||||||||||||
| IDD [mm] | AI | IDD [mm] | AI | |||||||||
| 2.1 | 0.8 | 38 | 0.88 | 0.02 | 3 | 1.8 | 0.58 | 32 | 0.88 | 0.01 | 2 | |
| 3.6 | 1.9 | 53 | 0.78 | 0.1 | 12 | 3.2 | 1.9 | 59 | 0.83 | 0.02 | 3 | |
| 3.9 | 2.6 | 67 | 0.67 | 0.07 | 10 | 3.2 | 1.8 | 56 | 0.78 | 0.02 | 2 | |
| 2.3 | 1 | 43 | 0.75 | 0.06 | 8 | 2.3 | 0.9 | 39 | 0.77 | 0.05 | 6 | |
| 6 | 4 | 67 | 0.61 | 0.15 | 24 | 4.5 | 2.1 | 47 | 0.73 | 0.14 | 20 | |
| 2.6 | 1.1 | 42 | 0.82 | 0.02 | 2 | 2.6 | 1 | 38 | 0.83 | 0.02 | 2 | |
| 6 | 4.1 | 68 | 0.64 | 0.09 | 14 | 3.6 | 1.8 | 50 | 0.76 | 0.05 | 7 | |
| 2.4 | 1.2 | 50 | 0.85 | 0.02 | 2 | 2.2 | 1 | 45 | 0.86 | 0.04 | 4 | |
| 3 | 2.9 | 97 | 0.81 | 0.04 | 5 | 2.9 | 1.8 | 62 | 0.80 | 0.05 | 6 | |
| 4.5 | 3.5 | 78 | 0.77 | 0.07 | 9 | 3.3 | 2 | 61 | 0.84 | 0.02 | 2 | |
| 3.3 | 2 | 61 | 0.74 | 0.09 | 12 | 2.5 | 1.3 | 52 | 0.83 | 0.02 | 3 | |
| 3.4 | 2.3 | 68 | 0.77 | 0.06 | 8 | 3.6 | 1.7 | 47 | 0.80 | 0.02 | 2 | |
| 3.6 | 2.3 | 61 | 0.76 | 0.07 | 9 | 3 | 1.5 | 49 | 0.81 | 0.04 | 5 | |
CoV = Coefficient of Variance; CTVLC = Clinical Target Volume of Lumpectomy Cavity; SD = Standard Deviation