Literature DB >> 24551656

Stress distribution in implant retained finger prosthesis: a finite element study.

Pokpong Amornvit1, Dinesh Rokaya1, Konrawee Keawcharoen2, Nimit Thongpulsawasdi3.   

Abstract

BACKGROUND: Finger amputation may result from congenital cause, trauma, infection and tumours. The finger amputation may be rehabilitated with dental implant-retained finger prosthesis. The success of implant-retained finger prosthesis is determined by the implant loading. The type of the force is a determining factor in implant loading.
OBJECTIVE: To evaluate stress distributions in finger bone when the loading force is applied along the long axis of the implant using finite element analysis.
METHOD: The finite element models were created. The finger bone model containing cortical bone and cancellous bone was constructed by using radiograph. Astra Tech Osseo Speed bone level implant of 4.5 mm diameter and 14 mm length was selected. The force was applied to the top of the abutment along the long axis of the implant.
RESULTS: Finite element analysis indicated that the maximum stress was located at the head of abutment screw. The minimum stress was located in the apical third of the implant fixture. The weakest point was calculated by safety factor which is located in the spongy bone at apical third of the fixtures. Finally, 4.9 times yield stress of spongy bone was needed for the deformation of the spongy bone.
CONCLUSION: Finite element study showed that when the force was applied along the long axis of the implant, the maximum stress was located around the neck of the implant and the cortex bone received more stress than cancellous bone. So, to achieve long term success, the designers of implant systems must confront biomaterial and biomechanical problems including in vivo forces on implants, load transmission to the interface and interfacial tissue response.

Entities:  

Keywords:  Dental implant; Finger prosthesis; Finite element analysis; Stress

Year:  2013        PMID: 24551656      PMCID: PMC3919359          DOI: 10.7860/JCDR/2013/7001.3775

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  13 in total

Review 1.  Application of finite element analysis in implant dentistry: a review of the literature.

Authors:  J P Geng; K B Tan; G R Liu
Journal:  J Prosthet Dent       Date:  2001-06       Impact factor: 3.426

2.  Two dental implants designed for immediate loading: a finite element analysis.

Authors:  Laurent Pierrisnard; Guy Hure; Michel Barquins; Daniel Chappard
Journal:  Int J Oral Maxillofac Implants       Date:  2002 May-Jun       Impact factor: 2.804

3.  A conical implant-abutment interface at the level of the marginal bone improves the distribution of stresses in the supporting bone. An axisymmetric finite element analysis.

Authors:  Stig Hansson
Journal:  Clin Oral Implants Res       Date:  2003-06       Impact factor: 5.977

4.  Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible.

Authors:  H J Meijer; J H Kuiper; F J Starmans; F Bosman
Journal:  J Prosthet Dent       Date:  1992-07       Impact factor: 3.426

5.  Evaluation of stress induced in peri-implant bone tissue by misfit in multi-implant prosthesis.

Authors:  Arturo N Natali; Piero G Pavan; Andrea L Ruggero
Journal:  Dent Mater       Date:  2005-09-29       Impact factor: 5.304

6.  One- vs two stage surgery technique for implant placement in finger prosthesis.

Authors:  Pokpong Amornvit; Dinesh Rokaya; Konrawee Keawcharoen; Somchart Raucharernporn; Nimit Thongpulsawasdi
Journal:  J Clin Diagn Res       Date:  2013-09-10

7.  Effects of implant diameter, insertion depth, and loading angle on stress/strain fields in implant/jawbone systems: finite element analysis.

Authors:  Lihe Qian; Mitsugu Todo; Yasuyuki Matsushita; Kiyoshi Koyano
Journal:  Int J Oral Maxillofac Implants       Date:  2009 Sep-Oct       Impact factor: 2.804

8.  Osseointegrated thumb prostheses: a concept for fixation of digit prosthetic devices.

Authors:  G Lundborg; P I Brånemark; B Rosén
Journal:  J Hand Surg Am       Date:  1996-03       Impact factor: 2.230

9.  Bending overload and implant fracture: a retrospective clinical analysis.

Authors:  B Rangert; P H Krogh; B Langer; N Van Roekel
Journal:  Int J Oral Maxillofac Implants       Date:  1995 May-Jun       Impact factor: 2.804

10.  Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system.

Authors:  M Quirynen; I Naert; D van Steenberghe
Journal:  Clin Oral Implants Res       Date:  1992-09       Impact factor: 5.977

View more
  6 in total

1.  Safety and efficacy of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent.

Authors:  Jinzhou Zhu; Huizhu Liu; Haipo Cui; Zhirong Tang; Chengli Song; Ruiyan Zhang
Journal:  J Mater Sci Mater Med       Date:  2017-02-14       Impact factor: 3.896

2.  Three-dimensional finite element analysis of a newly designed onplant miniplate anchorage system.

Authors:  Lin Liu; Yin-Ying Qu; Li-Jun Jiang; Qian Zhou; Tian-Qi Tang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2016-07-05

3.  Comparison of Different Types of Static Computer-Guided Implant Surgery in Varying Bone Inclinations.

Authors:  Pisut Thangwarawut; Pokpong Amornvit; Dinesh Rokaya; Sirichai Kiattavorncharoen
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

Review 4.  Osseointegrated Metallic Implants for Finger Amputees: A Review of the Literature.

Authors:  Chiara Bregoli; Carlo Alberto Biffi; Kavin Morellato; Emanuele Gruppioni; Matteo Primavera; Michele Rampoldi; Mario Lando; Roberto Adani; Ausonio Tuissi
Journal:  Orthop Surg       Date:  2022-05-07       Impact factor: 2.279

5.  Healing Abutment Distortion in Implant Prostheses: An In Vitro Study.

Authors:  Chandrashekhar Pandey; Bishwa Prakash Bhattarai; Apiwat Riddhabhaya; Natthamet Wongsirichat; Dinesh Rokaya
Journal:  J Funct Biomater       Date:  2022-06-21

6.  Four lateral mass screw fixation techniques in lower cervical spine following laminectomy: a finite element analysis study of stress distribution.

Authors:  Mingzhi Song; Zhen Zhang; Ming Lu; Junwei Zong; Chao Dong; Kai Ma; Shouyu Wang
Journal:  Biomed Eng Online       Date:  2014-08-09       Impact factor: 2.819

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.