Literature DB >> 27376815

Three-dimensional finite element analysis of a newly designed onplant miniplate anchorage system.

Lin Liu1, Yin-Ying Qu2, Li-Jun Jiang3, Qian Zhou2, Tian-Qi Tang2.   

Abstract

The purpose of this research was to evaluate the structural stress and deformation of a newly designed onplant miniplate anchorage system compared to a standard anchorage system. A bone block integrated with a novel miniplate and fixation screw system was simulated in a three-dimensional model and subjected to force at different directions. The stress distribution and deformation of the miniplate system and cortical bone were evaluated using the three-dimensional finite element method. The results showed that the stress on the plate system and bone was linearly proportional to the force magnitude and was higher when the force was in a vertical direction (Y-axis). Stress and deformation values of the two screws (screw 1 and 2) were asymmetric when the force was added along Y-axis and was greater in screw 1. The highest deformation value of the screws was 7.5148 μm, much smaller than the limit value. The load was decreased for each single miniscrew, and the ability of the new anchorage system to bear the load was also enhanced to some degree. It was suggested that the newly designed onplant miniplate anchorage system is effective, easily implanted and minimally invasive.

Entities:  

Keywords:  finite element analysis; onplant miniplate anchorage system; skeletal anchorage system; temporary skeletal anchorage devices

Mesh:

Year:  2016        PMID: 27376815     DOI: 10.1007/s11596-016-1603-x

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  16 in total

1.  Comparison of transverse dimensional changes in surgical skeletal Class III patients with and without presurgical orthodontics.

Authors:  Yu-Chih Wang; Ellen Wen-Ching Ko; Chiung-Shing Huang; Yu-Ray Chen; Teruko Takano-Yamamoto
Journal:  J Oral Maxillofac Surg       Date:  2010-05-20       Impact factor: 1.895

2.  Finite element analysis of the strain distribution in the humeral head tubercles during abduction: comparison of young and osteoporotic bone.

Authors:  Ph Clavert; M Zerah; J Krier; P Mille; J F Kempf; J L Kahn
Journal:  Surg Radiol Anat       Date:  2006-08-26       Impact factor: 1.246

3.  Skeletal anchorage for orthodontic correction of severe maxillary protrusion after previous orthodontic treatment.

Authors:  Eiji Tanaka; Akiko Nishi-Sasaki; Takuro Hasegawa; Clarice Nishio; Nobuhiko Kawai; Kazuo Tanne
Journal:  Angle Orthod       Date:  2008-01       Impact factor: 2.079

4.  Closure of severe skeletal anterior open bite with zygomatic anchorage.

Authors:  Laszlo Seres; Andras Kocsis
Journal:  J Craniofac Surg       Date:  2009-03       Impact factor: 1.046

5.  The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone.

Authors:  M Motoyoshi; M Inaba; A Ono; S Ueno; N Shimizu
Journal:  Int J Oral Maxillofac Surg       Date:  2008-10-28       Impact factor: 2.789

Review 6.  Survival and failure rates of orthodontic temporary anchorage devices: a systematic review.

Authors:  Marc Schätzle; Roland Männchen; Marcel Zwahlen; Niklaus P Lang
Journal:  Clin Oral Implants Res       Date:  2009-09-30       Impact factor: 5.977

Review 7.  Temporary skeletal anchorage devices for orthodontics.

Authors:  Bernard J Costello; Ramon L Ruiz; Joseph Petrone; Jacqueline Sohn
Journal:  Oral Maxillofac Surg Clin North Am       Date:  2010-02       Impact factor: 2.802

8.  Stress distribution in implant retained finger prosthesis: a finite element study.

Authors:  Pokpong Amornvit; Dinesh Rokaya; Konrawee Keawcharoen; Nimit Thongpulsawasdi
Journal:  J Clin Diagn Res       Date:  2013-12-15

9.  Relationship between magnitude of immediate loading and peri-implant osteogenesis in dogs.

Authors:  Daisuke Esaki; Yasuyuki Matsushita; Yasunori Ayukawa; Nobuo Sakai; Yoshinori Sawae; Kiyoshi Koyano
Journal:  Clin Oral Implants Res       Date:  2011-09-27       Impact factor: 5.977

10.  Patients' and orthodontists' perceptions of miniplates used for temporary skeletal anchorage: a prospective study.

Authors:  Marie A Cornelis; Nicole R Scheffler; Catherine Nyssen-Behets; Hugo J De Clerck; J F Camilla Tulloch
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-01       Impact factor: 2.650

View more
  1 in total

1.  Evaluation of Long-term Stability of Vertical Control in Hyperdivergent Patients Treated with Temporary Anchorage Devices.

Authors:  Jin-Rong Deng; Yan-Ang Li; Xue-Dong Wang; Jing Li; Yun Ding; Yan-Heng Zhou
Journal:  Curr Med Sci       Date:  2018-10-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.