Literature DB >> 24532480

Phase contrast MRI with flow compensation view sharing.

Da Wang1, Jiaxin Shao, Stanislas Rapacchi, Matthew J Middione, Daniel B Ennis, Peng Hu.   

Abstract

PURPOSE: To develop and evaluate a technique for accelerating phase contrast MRI (PC-MRI) acquisitions without significant compromise in flow quantification accuracy.
METHODS: PC-MRI is commonly acquired using interleaved flow-compensated (FC) and flow-encoded (FE) echoes. We hypothesized that FC data, which represent background phase, do not change significantly over time. Therefore, we proposed to undersample the FC data and use an FC view sharing (FCVS) approach to synthesize a composite FC frame for each corresponding FE frame. FCVS was evaluated in a flow phantom and healthy volunteers and compared with a standard FC/FE PC-MRI.
RESULTS: The FCVS sequence resulted in an error of 0.0% for forward flow and 2.0% for reverse flow volume when compared with FC/FE PC-MRI in a flow phantom. Measurements in the common carotid arteries showed that the FCVS method had -1.16 cm/s bias for maximum peak velocity and -0.019 mL bias in total flow, when compared with FC/FE with the same temporal resolution, but double the total acquisition time. These results represent ≤1.3% bias error in velocity and volumetric flow quantification.
CONCLUSION: FCVS can accelerate PC-MRI acquisitions while maintaining flow and velocity measurement accuracy when there is limited temporal variation in the FC data.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  flow quantification; flow rate; phase contrast MRI; temporal footprint; temporal resolution; velocity encoding; view sharing

Mesh:

Year:  2014        PMID: 24532480      PMCID: PMC4459783          DOI: 10.1002/mrm.25133

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography.

Authors:  Tianliang Gu; Frank R Korosec; Walter F Block; Sean B Fain; Quill Turk; Darren Lum; Yong Zhou; Thomas M Grist; Victor Haughton; Charles A Mistretta
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

4.  Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA).

Authors:  Felix A Breuer; Peter Kellman; Mark A Griswold; Peter M Jakob
Journal:  Magn Reson Med       Date:  2005-04       Impact factor: 4.668

5.  Optimal phase difference reconstruction: comparison of two methods.

Authors:  Kun Lu; Thomas T Liu; Mark Bydder
Journal:  Magn Reson Imaging       Date:  2007-06-15       Impact factor: 2.546

6.  Sparse MRI: The application of compressed sensing for rapid MR imaging.

Authors:  Michael Lustig; David Donoho; John M Pauly
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

7.  3D blood flow characteristics in the carotid artery bifurcation assessed by flow-sensitive 4D MRI at 3T.

Authors:  A Harloff; F Albrecht; J Spreer; A F Stalder; J Bock; A Frydrychowicz; J Schöllhorn; A Hetzel; M Schumacher; J Hennig; M Markl
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

Review 8.  Cardiovascular applications of phase-contrast MRI.

Authors:  Monvadi B Srichai; Ruth P Lim; Samson Wong; Vivian S Lee
Journal:  AJR Am J Roentgenol       Date:  2009-03       Impact factor: 3.959

9.  Carotid artery stenosis: clinical efficacy of MR phase-contrast flow quantification as an adjunct to MR angiography.

Authors:  R L Vanninen; H I Manninen; P L Partanen; P A Vainio; S Soimakallio
Journal:  Radiology       Date:  1995-02       Impact factor: 11.105

10.  3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain.

Authors:  Clifton R Haider; Houchun Harry Hu; Norbert G Campeau; John Huston; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

View more
  1 in total

1.  Phase-contrast MRI with hybrid one and two-sided flow-encoding and velocity spectrum separation.

Authors:  Da Wang; Jiaxin Shao; Daniel B Ennis; Peng Hu
Journal:  Magn Reson Med       Date:  2016-08-09       Impact factor: 4.668

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.