Literature DB >> 19097219

3D blood flow characteristics in the carotid artery bifurcation assessed by flow-sensitive 4D MRI at 3T.

A Harloff1, F Albrecht, J Spreer, A F Stalder, J Bock, A Frydrychowicz, J Schöllhorn, A Hetzel, M Schumacher, J Hennig, M Markl.   

Abstract

To determine three-dimensional (3D) blood flow patterns in the carotid bifurcation, 10 healthy volunteers and nine patients with internal carotid artery (ICA) stenosis > or =50% were examined by flow-sensitive 4D MRI at 3T. Absolute and mean blood velocities, pulsatility index (PI), and resistance index (RI) were measured in the common carotid arteries (CCAs) by duplex sonography (DS) and compared with flow-sensitive 4D MRI. Furthermore, 3D MRI blood flow patterns in the carotid bifurcation of volunteers and patients before and after recanalization were graded by two independent readers. Blood flow velocities measured by MRI were 31-39% lower than in DS. However, PI and RI differed by only 13-16%. Rating of 3D flow characteristics in the ICA revealed consistent patterns for filling and helical flow in volunteers. In patients with ICA stenosis, 3D blood flow visualization was successfully employed to detect markedly altered filling and helical flow patterns (forward-moving spiral flow) in the ICA bulb and to evaluate the effect of revascularization, which restored filling and helical flow. Our results demonstrate the feasibility of flow-sensitive 4D MRI for the quantification and 3D visualization of physiological and pathological flow patterns in the carotid artery bifurcation.

Entities:  

Mesh:

Year:  2009        PMID: 19097219     DOI: 10.1002/mrm.21774

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  46 in total

1.  Four-dimensional flow MRI for evaluation of post-stenotic turbulent flow in a phantom: comparison with flowmeter and computational fluid dynamics.

Authors:  Jihoon Kweon; Dong Hyun Yang; Guk Bae Kim; Namkug Kim; MunYoung Paek; Aurelien F Stalder; Andreas Greiser; Young-Hak Kim
Journal:  Eur Radiol       Date:  2016-01-08       Impact factor: 5.315

Review 2.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

Review 3.  [Diagnosing stroke aetiologies. Morphologic and functional analysis of the aorta and carotid arteries by MRI].

Authors:  A Harloff; M Markl; A Frydrychowicz; J Hennig; C Weiller
Journal:  Nervenarzt       Date:  2009-08       Impact factor: 1.214

4.  Wall shear stress distribution at the carotid bifurcation: influence of eversion carotid endarterectomy.

Authors:  A Harloff; S Berg; A J Barker; J Schöllhorn; M Schumacher; C Weiller; M Markl
Journal:  Eur Radiol       Date:  2013-06-29       Impact factor: 5.315

Review 5.  Intracardiac flow visualization: current status and future directions.

Authors:  Daniel Rodriguez Muñoz; Michael Markl; José Luis Moya Mur; Alex Barker; Covadonga Fernández-Golfín; Patrizio Lancellotti; José Luis Zamorano Gómez
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2013-08-01       Impact factor: 6.875

6.  Dampening of blood-flow pulsatility along the carotid siphon: does form follow function?

Authors:  T Schubert; F Santini; A F Stalder; J Bock; S Meckel; L Bonati; M Markl; S Wetzel
Journal:  AJNR Am J Neuroradiol       Date:  2011-04-07       Impact factor: 3.825

7.  In vivo analysis of physiological 3D blood flow of cerebral veins.

Authors:  Florian Schuchardt; Laure Schroeder; Constantin Anastasopoulos; Michael Markl; Jochen Bäuerle; Anja Hennemuth; Johann Drexl; José M Valdueza; Irina Mader; Andreas Harloff
Journal:  Eur Radiol       Date:  2015-02-01       Impact factor: 5.315

8.  Optimal 4DFlow MR sequence parameters for the assessment of internal carotid artery stenosis: a simulation study.

Authors:  Myriam Edjlali; Catherine Oppenheim; Joseph Benzakoun; Pauline Roca; David Calvet; Olivier Naggara; Stéphanie Lion; Marie-Pierre Gobin-Metteil; Sylvain Charron; Victoria Cavero; Jean-François Meder
Journal:  Neuroradiology       Date:  2019-06-13       Impact factor: 2.804

9.  4D-MR flow analysis in patients after repair for tetralogy of Fallot.

Authors:  J Geiger; M Markl; B Jung; J Grohmann; B Stiller; M Langer; R Arnold
Journal:  Eur Radiol       Date:  2011-03-29       Impact factor: 5.315

10.  Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI.

Authors:  Stephan Meckel; Lorenz Leitner; Leo H Bonati; Francesco Santini; Tilman Schubert; Aurelien F Stalder; Philippe Lyrer; Michael Markl; Stephan G Wetzel
Journal:  Neuroradiology       Date:  2012-11-10       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.