Literature DB >> 15799044

Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA).

Felix A Breuer1, Peter Kellman, Mark A Griswold, Peter M Jakob.   

Abstract

Current parallel imaging techniques for accelerated imaging require a fully encoded reference data set to estimate the spatial coil sensitivity information needed for reconstruction. In dynamic parallel imaging a time-interleaved acquisition scheme can be used, which eliminates the need for separately acquiring additional reference data, since the signal from directly adjacent time frames can be merged to build a set of fully encoded full-resolution reference data for coil calibration. In this work, we demonstrate that a time-interleaved sampling scheme, in combination with autocalibrated GRAPPA (referred to as TGRAPPA), allows one to easily update the coil weights for the GRAPPA algorithm dynamically, thereby improving the acquisition efficiency. This method may update coil sensitivity estimates frame by frame, thereby tracking changes in relative coil sensitivities that may occur during the data acquisition. Copyright 2005 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 15799044     DOI: 10.1002/mrm.20430

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  87 in total

1.  Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI.

Authors:  Ricardo Otazo; Daniel Kim; Leon Axel; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

2.  Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine.

Authors:  Kai Nassenstein; Holger Eberle; Stefan Maderwald; Christoph J Jensen; Christina Heilmaier; Thomas Schlosser; Oliver Bruder
Journal:  Eur Radiol       Date:  2010-06-09       Impact factor: 5.315

3.  Motion compensated magnetic resonance reconstruction using inverse-consistent deformable registration: application to real-time cine imaging.

Authors:  Hui Xue; Yu Ding; Christoph Guetter; Marie-Pierre Jolly; Jens Guehring; Sven Zuehlsdorff; Orlando P Simonetti
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

4.  Parallel acquisition for effective density weighted imaging: PLANED imaging.

Authors:  Oliver M Geier; Dietbert Hahn; Herbert Köstler
Journal:  MAGMA       Date:  2007-01-20       Impact factor: 2.310

5.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

6.  Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise.

Authors:  Stefan Skare; Rexford D Newbould; David B Clayton; Gregory W Albers; Scott Nagle; Roland Bammer
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

7.  Fast four-dimensional coronary MR angiography with k-t GRAPPA.

Authors:  Peng Lai; Feng Huang; Andrew C Larson; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

8.  Carotid intima-media thickness and distensibility measured by MRI at 3 T versus high-resolution ultrasound.

Authors:  Andreas Harloff; Timo Zech; Alex Frydrychowicz; Martin Schumacher; Joachim Schöllhorn; Jürgen Hennig; Cornelius Weiller; Michael Markl
Journal:  Eur Radiol       Date:  2009-02-13       Impact factor: 5.315

9.  Quantitative image quality evaluation of MR images using perceptual difference models.

Authors:  Jun Miao; Donglai Huo; David L Wilson
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

10.  The Importance of k-Space Trajectory on Off-Resonance Artifact in Segmented Echo-Planar Imaging.

Authors:  Jacob A Bender; Rizwan Ahmad; Orlando P Simonetti
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2013-03-01       Impact factor: 0.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.