Orthogonal resonators for pulse in vivo electron paramagnetic imaging at 250 MHz.

Subramanian V Sundramoorthy1, Boris Epel2, Howard J Halpern3.   

Abstract

A 250 MHz bimodal resonator with a 19 mm internal diameter for in vivo pulse electron paramagnetic resonance (EPR) imaging is presented. Two separate coaxial cylindrical resonators inserted one into another were used for excitation and detection. The Alderman-Grant excitation resonator (AGR) showed the highest efficiency among all the excitation resonators tested. The magnetic field of AGR is confined to the volume of the detection resonator, which results in highly efficient use of the radio frequency power. A slotted inner single loop single gap resonator (SLSG LGR), coaxial to the AGR, was used for signal detection. The resulting bimodal resonator (AG/LGR) has two mutually orthogonal magnetic field modes; one of them has the magnetic field in the axial direction. The resonator built in our laboratory achieved 40 dB isolation over 20 MHz bandwidth with quality factors of detection and excitation resonators of 36 and 11 respectively. Considerable improvement of the B1 homogeneity and EPR image quality in comparison with reflection loop-gap resonator of similar size and volume was observed.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  EPR; EPR imaging; In vivo; Resonator

Mesh:

Year:  2014        PMID: 24530507      PMCID: PMC3974126          DOI: 10.1016/j.jmr.2013.12.015

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  13 in total

1.  Parallel coil resonators for time-domain radiofrequency electron paramagnetic resonance imaging of biological objects.

Authors:  N Devasahayam; S Subramanian; R Murugesan; J A Cook; M Afeworki; R G Tschudin; J B Mitchell; M C Krishna
Journal:  J Magn Reson       Date:  2000-01       Impact factor: 2.229

Review 2.  Hypoxia: importance in tumor biology, noninvasive measurement by imaging, and value of its measurement in the management of cancer therapy.

Authors:  James L Tatum; Gary J Kelloff; Robert J Gillies; Jeffrey M Arbeit; J Martin Brown; K S Clifford Chao; J Donald Chapman; William C Eckelman; Anthony W Fyles; Amato J Giaccia; Richard P Hill; Cameron J Koch; Murali Cherukuri Krishna; Kenneth A Krohn; Jason S Lewis; Ralph P Mason; Giovanni Melillo; Anwar R Padhani; Garth Powis; Joseph G Rajendran; Richard Reba; Simon P Robinson; Gregg L Semenza; Harold M Swartz; Peter Vaupel; David Yang; Barbara Croft; John Hoffman; Guoying Liu; Helen Stone; Daniel Sullivan
Journal:  Int J Radiat Biol       Date:  2006-10       Impact factor: 2.694

3.  Modified Alderman-Grant resonator with high-power stability for proton electron double resonance imaging.

Authors:  Sergey Petryakov; Alexandre Samouilov; Michael Roytenberg; Haihong Li; Jay L Zweier
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

4.  A simple design for a double-tunable probe head for imaging and spectroscopy at high fields.

Authors:  R Gruetter; C Boesch; M Müri; E Martin; K Wüthrich
Journal:  Magn Reson Med       Date:  1990-07       Impact factor: 4.668

5.  Electron paramagnetic resonance-based pH mapping using spectral-spatial imaging of sequentially scanned spectra.

Authors:  Shunichi Koda; Jonathan Goodwin; Valery V Khramtsov; Hirotada Fujii; Hiroshi Hirata
Journal:  Anal Chem       Date:  2012-03-28       Impact factor: 6.986

6.  In vivo monitoring of pH, redox status, and glutathione using L-band EPR for assessment of therapeutic effectiveness in solid tumors.

Authors:  Andrey A Bobko; Timothy D Eubank; Jeffrey L Voorhees; Olga V Efimova; Igor A Kirilyuk; Sergey Petryakov; Dmitrii G Trofimiov; Clay B Marsh; Jay L Zweier; Igor A Grigor'ev; Alexandre Samouilov; Valery V Khramtsov
Journal:  Magn Reson Med       Date:  2011-11-23       Impact factor: 4.668

7.  A Wire Crossed-Loop-Resonator for Rapid Scan EPR.

Authors:  George A Rinard; Richard W Quine; Joshua R Biller; Gareth R Eaton
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2010-04-09       Impact factor: 1.176

8.  Direct-detected rapid-scan EPR at 250 MHz.

Authors:  James W Stoner; Dennis Szymanski; Sandra S Eaton; Richard W Quine; George A Rinard; Gareth R Eaton
Journal:  J Magn Reson       Date:  2004-09       Impact factor: 2.229

9.  A Versatile High Speed 250 MHz Pulse Imager for Biomedical Applications.

Authors:  Boris Epel; Subramanian V Sundramoorthy; Colin Mailer; Howard J Halpern
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2008-07-10       Impact factor: 1.176

10.  A Modified Alderman-Grant Coil makes possible an efficient cross-coil probe for high field solid-state NMR of lossy biological samples.

Authors:  Christopher V Grant; Yuan Yang; Mira Glibowicka; Chin H Wu; Sang Ho Park; Charles M Deber; Stanley J Opella
Journal:  J Magn Reson       Date:  2009-08-15       Impact factor: 2.229

View more
  6 in total

1.  Oxygen Sensing with Perfluorocarbon-Loaded Ultraporous Mesostructured Silica Nanoparticles.

Authors:  Amani L Lee; Clifford T Gee; Bradley P Weegman; Samuel A Einstein; Adam R Juelfs; Hattie L Ring; Katie R Hurley; Sam M Egger; Garrett Swindlehurst; Michael Garwood; William C K Pomerantz; Christy L Haynes
Journal:  ACS Nano       Date:  2017-05-22       Impact factor: 15.881

2.  EPR Imaging Spin Probe Trityl Radical OX063: A Method for Its Isolation from Animal Effluent, Redox Chemistry of Its Quinone Methide Oxidation Product, and in Vivo Application in a Mouse.

Authors:  Maciej Serda; Yen-Ku Wu; Eugene D Barth; Howard J Halpern; Viresh H Rawal
Journal:  Chem Res Toxicol       Date:  2016-11-22       Impact factor: 3.739

3.  250 MHz Rapid Scan Cross Loop Resonator.

Authors:  Laura A Buchanan; Lukas B Woodcock; George A Rinard; Richard W Quine; Yilin Shi; Sandra S Eaton; Gareth R Eaton
Journal:  Appl Magn Reson       Date:  2018-10-03       Impact factor: 0.831

4.  Resonators for In Vivo Imaging: Practical Experience.

Authors:  George A Rinard; Richard W Quine; Laura A Buchanan; Sandra S Eaton; Gareth R Eaton; Boris Epel; Subramanian V Sundramoorthy; Howard J Halpern
Journal:  Appl Magn Reson       Date:  2017-09-22       Impact factor: 0.831

5.  Decoupling of excitation and receive coils in pulsed magnetic resonance using sinusoidal magnetic field modulation.

Authors:  Mark Tseytlin; Boris Epel; Subramanian Sundramoorthy; Dmitriy Tipikin; Howard J Halpern
Journal:  J Magn Reson       Date:  2016-09-07       Impact factor: 2.229

Review 6.  EPR Everywhere.

Authors:  Joshua R Biller; Joseph E McPeak
Journal:  Appl Magn Reson       Date:  2021-01-24       Impact factor: 0.831

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.