250 MHz Rapid Scan Cross Loop Resonator.

Laura A Buchanan1, Lukas B Woodcock1, George A Rinard2, Richard W Quine2, Yilin Shi1, Sandra S Eaton1, Gareth R Eaton1.   

Abstract

A 25 mm diameter 250 MHz crossed-loop resonator was designed for rapid scan electron paramagnetic resonance imaging. It has a saddle coil for the driven resonator and a fine wire, loop gap resonator for the sample resonator. There is good separation of E and B fields and high isolation between the two resonators, permitting a wide range of sample types to be measured. Applications to imaging of nitroxide, trityl, and LiPc samples illustrate the utility of the resonator. Using this resonator and a trityl sample the signal-to-noise of a rapid scan absorption spectrum is about 20 times higher than for a first-derivative CW spectrum.

Entities:  

Year:  2018        PMID: 30799909      PMCID: PMC6380496          DOI: 10.1007/s00723-018-1078-y

Source DB:  PubMed          Journal:  Appl Magn Reson        ISSN: 0937-9347            Impact factor:   0.831


  23 in total

1.  Parallel coil resonators for time-domain radiofrequency electron paramagnetic resonance imaging of biological objects.

Authors:  N Devasahayam; S Subramanian; R Murugesan; J A Cook; M Afeworki; R G Tschudin; J B Mitchell; M C Krishna
Journal:  J Magn Reson       Date:  2000-01       Impact factor: 2.229

2.  Application of continuous-wave EPR spectral-spatial image reconstruction techniques for in vivo oxymetry: comparison of projection reconstruction and constant-time modalities.

Authors:  Ken-ichiro Matsumoto; Baby Chandrika; Joost A B Lohman; James B Mitchell; Murali C Krishna; Sankaran Subramanian
Journal:  Magn Reson Med       Date:  2003-10       Impact factor: 4.668

3.  Solving the problem of concomitant gradients in ultra-low-field MRI.

Authors:  Jaakko O Nieminen; Risto J Ilmoniemi
Journal:  J Magn Reson       Date:  2010-09-08       Impact factor: 2.229

4.  Image artifacts in very low magnetic field MRI: the role of concomitant gradients.

Authors:  Dmitriy A Yablonskiy; Alexander L Sukstanskii; Joseph J H Ackerman
Journal:  J Magn Reson       Date:  2005-06       Impact factor: 2.229

5.  On concomitant gradients in low-field MRI.

Authors:  P L Volegov; J C Mosher; M A Espy; R H Kraus
Journal:  J Magn Reson       Date:  2005-07       Impact factor: 2.229

6.  Advantageous application of a surface coil to EPR irradiation in overhauser-enhanced MRI.

Authors:  Shingo Matsumoto; Kenichi Yamada; Hiroshi Hirata; Keiji Yasukawa; Fuminori Hyodo; Kazuhiro Ichikawa; Hideo Utsumi
Journal:  Magn Reson Med       Date:  2007-04       Impact factor: 4.668

7.  A Wire Crossed-Loop-Resonator for Rapid Scan EPR.

Authors:  George A Rinard; Richard W Quine; Joshua R Biller; Gareth R Eaton
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2010-04-09       Impact factor: 1.176

8.  Deconvolution of sinusoidal rapid EPR scans.

Authors:  Mark Tseitlin; George A Rinard; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2010-11-26       Impact factor: 2.229

9.  Three-dimensional whole body imaging of spin probes in mice by time-domain radiofrequency electron paramagnetic resonance.

Authors:  M Afeworki; G M van Dam; N Devasahayam; R Murugesan; J Cook; D Coffin; J H Larsen; J B Mitchell; S Subramanian; M C Krishna
Journal:  Magn Reson Med       Date:  2000-03       Impact factor: 4.668

10.  A loop resonator for slice-selective in vivo EPR imaging in rats.

Authors:  Hiroshi Hirata; Guanglong He; Yuanmu Deng; Ildar Salikhov; Sergey Petryakov; Jay L Zweier
Journal:  J Magn Reson       Date:  2007-10-30       Impact factor: 2.229

View more
  1 in total

1.  Rapid-scan EPR imaging of a phantom comprised of species with different linewidths and relaxation times.

Authors:  Yilin Shi; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2019-09-07       Impact factor: 2.229

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.