Literature DB >> 24461335

Under-response correction for EBT3 films in the presence of proton spread out Bragg peaks.

F Fiorini1, D Kirby2, J Thompson3, S Green2, D J Parker4, B Jones3, M A Hill3.   

Abstract

We present a study of the under-response of the new Gafchromic EBT3 films and a procedure to accurately perform 2D and 3D proton dosimetry measurements for both pristine and spread out Bragg peaks (SOBP) of any energy. These new films differ from the previous EBT2 generation by a slightly different active layer composition, which we show has not effected appreciably their response. The procedure and the beam quality correction factor curve have been benchmarked using 29 MeV modulated proton beams. In order to show the correction to apply when EBT3 films are used as treatment verification tools in anthropomorphic phantoms, two simulation studies involving clinical energies are presented: a SOBP for eye treatments and a SOBP to treat 20 cm deep and 5 cm thick tumours. We find maximum under-responses of 37%, 30% and 7.7% for the modulated 29 MeV beam, eye and deep tumour treatment, respectively, which were attained close to the end of the peak tails, due to a higher proportion of very low energy protons. The maximum deviations between corrected and uncorrected doses were for the three cases, respectively, 20.7%, 8.3% and 2.1% of the average dose across flat region of the SOBP. These values were obtained close to the distal edge of the SOBPs, where the proportion of low energy protons was not as high as on the tail, but there still was a number of protons high enough to deposit a reasonable amount of dose in the films.
Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3D dosimetry; EBT3 Gafchromic films; FLUKA Monte Carlo code; Under-response correction

Mesh:

Substances:

Year:  2014        PMID: 24461335     DOI: 10.1016/j.ejmp.2013.12.006

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  10 in total

1.  Investigation of EBT2 and EBT3 films for proton dosimetry in the 4-20 MeV energy range.

Authors:  S Reinhardt; M Würl; C Greubel; N Humble; J J Wilkens; M Hillbrand; A Mairani; W Assmann; K Parodi
Journal:  Radiat Environ Biophys       Date:  2015-01-09       Impact factor: 1.925

2.  Patient-Specific QA of Spot-Scanning Proton Beams using Radiochromic Film.

Authors:  Maria F Chan; Chin-Cheng Chen; Chengyu Shi; Jingdong Li; Xiaoli Tang; Xiang Li; Dennis Mah
Journal:  Int J Med Phys Clin Eng Radiat Oncol       Date:  2017-05-16

3.  LET dependent response of GafChromic films investigated with MeV ion beams.

Authors:  V Grilj; D J Brenner
Journal:  Phys Med Biol       Date:  2018-12-18       Impact factor: 3.609

4.  An Anthropomorphic Head and Neck Quality Assurance Phantom for Credentialing of Intensity-Modulated Proton Therapy.

Authors:  Daniela Branco; Paige Taylor; Xiaodong Zhang; Heng Li; Michele Guindani; David Followill
Journal:  Int J Part Ther       Date:  2018-03-21

5.  Dose- rather than fluence-averaged LET should be used as a single-parameter descriptor of proton beam quality for radiochromic film dosimetry.

Authors:  Andreas Franz Resch; Paul David Heyes; Hermann Fuchs; Niels Bassler; Dietmar Georg; Hugo Palmans
Journal:  Med Phys       Date:  2020-03-13       Impact factor: 4.071

6.  Monte Carlo calculation of the mass stopping power of EBT3 and EBT-XD films for protons for energy ranges of 50-400 MeV.

Authors:  Chengyu Shi; Chin-Cheng Chen; Dennis Mah; Maria F Chan
Journal:  Precis Radiat Oncol       Date:  2018-11-19

7.  Radiosensitivity of colorectal cancer to 90Y and the radiobiological implications for radioembolisation therapy.

Authors:  Boon Q Lee; Elliot M Abbott; Sarah Able; James M Thompson; Mark A Hill; Christiana Kartsonaki; Katherine A Vallis; Nadia Falzone
Journal:  Phys Med Biol       Date:  2019-07-05       Impact factor: 4.174

8.  Dosimetric properties of a newly developed thermoluminescent sheet-type dosimeter for clinical proton beams.

Authors:  Takahiro Kato; Tatsuhiko Sagara; Shinya Komori; Ryohei Kato; Akihiko Takeuchi; Yuki Narita
Journal:  J Appl Clin Med Phys       Date:  2021-03-15       Impact factor: 2.102

9.  Skin Dosimetry with EBT3 Radiochromic Film in Radiotherapy of Parotid Cancer.

Authors:  Mohammad Taghi Bahreyni Toossi; Mahdi Ghorbani; Farideh Khorshidi; Mohammad Mohammadi; Nastaran Mohamadian; Fateme Akbari; Mahdie Dayani
Journal:  J Biomed Phys Eng       Date:  2021-10-01

10.  Phantom design and dosimetric characterization for multiple simultaneous cell irradiations with active pencil beam scanning.

Authors:  Monika Clausen; Suphalak Khachonkham; Sylvia Gruber; Peter Kuess; Rolf Seemann; Barbara Knäusl; Elisabeth Mara; Hugo Palmans; Wolfgang Dörr; Dietmar Georg
Journal:  Radiat Environ Biophys       Date:  2019-09-20       Impact factor: 1.925

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.