Investigation of EBT2 and EBT3 films for proton dosimetry in the 4-20 MeV energy range.

S Reinhardt1, M Würl2, C Greubel3, N Humble4, J J Wilkens4, M Hillbrand5, A Mairani6, W Assmann2, K Parodi2.   

Abstract

Radiochromic films such as Gafchromic EBT2 or EBT3 films are widely used for dose determination in radiation therapy because they offer a superior spatial resolution compared to any other digital dosimetric 2D detector array. The possibility to detect steep dose gradients is not only attractive for intensity-modulated radiation therapy with photons but also for intensity-modulated proton therapy. Their characteristic dose rate-independent response makes radiochromic films also attractive for dose determination in cell irradiation experiments using laser-driven ion accelerators, which are currently being investigated as future medical ion accelerators. However, when using these films in ion beams, the energy-dependent dose response in the vicinity of the Bragg peak has to be considered. In this work, the response of these films for low-energy protons is investigated. To allow for reproducible and background-free irradiation conditions, the films were exposed to mono-energetic protons from an electrostatic accelerator, in the 4-20 MeV energy range. For comparison, irradiation with clinical photons was also performed. It turned out that in general, EBT2 and EBT3 films show a comparable performance. For example, dose-response curves for photons and protons with energies as low as 11 MeV show almost no differences. However, corrections are required for proton energies below 11 MeV. Care has to be taken when correction factors are related to an average LET from depth-dose measurements, because only the dose-averaged LET yields similar results as obtained in mono-energetic measurements.

Mesh:

Substances:

Year:  2015        PMID: 25572031     DOI: 10.1007/s00411-014-0581-2

Source DB:  PubMed          Journal:  Radiat Environ Biophys        ISSN: 0301-634X            Impact factor:   1.925


  27 in total

1.  Comments on ICRU report no. 49: stopping powers and ranges for protons and alpha particles.

Authors:  J F Ziegler
Journal:  Radiat Res       Date:  1999-08       Impact factor: 2.841

2.  Relative effectiveness of polyacrylamide gel dosimeters applied to proton beams: Fourier transform Raman observations and track structure calculations.

Authors:  A Jirasek; C Duzenli
Journal:  Med Phys       Date:  2002-04       Impact factor: 4.071

3.  Dosimetry and spectral analysis of a radiobiological experiment using laser-driven proton beams.

Authors:  F Fiorini; D Kirby; M Borghesi; D Doria; J C G Jeynes; K F Kakolee; S Kar; S Kaur; K J Kirby; M J Merchant; S Green
Journal:  Phys Med Biol       Date:  2011-11-07       Impact factor: 3.609

4.  Dosimetric properties of Gafchromic(R) EBT films in medical carbon ion beams.

Authors:  Mária Martisíková; Oliver Jäkel
Journal:  Phys Med Biol       Date:  2010-08-31       Impact factor: 3.609

5.  Gafchromic EBT film dosimetry in proton beams.

Authors:  Li Zhao; Indra J Das
Journal:  Phys Med Biol       Date:  2010-04-29       Impact factor: 3.609

6.  Dosimetric properties of Gafchromic EBT films in monoenergetic medical ion beams.

Authors:  Mária Martisíková; Oliver Jäkel
Journal:  Phys Med Biol       Date:  2010-06-09       Impact factor: 3.609

7.  Precise radiochromic film dosimetry using a flat-bed document scanner.

Authors:  Slobodan Devic; Jan Seuntjens; Edwin Sham; Ervin B Podgorsak; C Ross Schmidtlein; Assen S Kirov; Christopher G Soares
Journal:  Med Phys       Date:  2005-07       Impact factor: 4.071

8.  Characterization and use of EBT radiochromic film for IMRT dose verification.

Authors:  Omar A Zeidan; Stacy Ann L Stephenson; Sanford L Meeks; Thomas H Wagner; Twyla R Willoughby; Patrick A Kupelian; Katja M Langen
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

9.  Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors.

Authors:  L Karsch; E Beyreuther; T Burris-Mog; S Kraft; C Richter; K Zeil; J Pawelke
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

10.  An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan.

Authors:  David Lewis; Andre Micke; Xiang Yu; Maria F Chan
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

View more
  7 in total

1.  Patient-Specific QA of Spot-Scanning Proton Beams using Radiochromic Film.

Authors:  Maria F Chan; Chin-Cheng Chen; Chengyu Shi; Jingdong Li; Xiaoli Tang; Xiang Li; Dennis Mah
Journal:  Int J Med Phys Clin Eng Radiat Oncol       Date:  2017-05-16

2.  LET dependent response of GafChromic films investigated with MeV ion beams.

Authors:  V Grilj; D J Brenner
Journal:  Phys Med Biol       Date:  2018-12-18       Impact factor: 3.609

3.  Dose- rather than fluence-averaged LET should be used as a single-parameter descriptor of proton beam quality for radiochromic film dosimetry.

Authors:  Andreas Franz Resch; Paul David Heyes; Hermann Fuchs; Niels Bassler; Dietmar Georg; Hugo Palmans
Journal:  Med Phys       Date:  2020-03-13       Impact factor: 4.071

4.  Enhancement of the ionoacoustic effect through ultrasound and photoacoustic contrast agents.

Authors:  Julie Lascaud; Pratik Dash; Matthias Würl; Hans-Peter Wieser; Benjamin Wollant; Ronaldo Kalunga; Walter Assmann; Dirk-André Clevert; Alfredo Ferrari; Paola Sala; Alessandro Stuart Savoia; Katia Parodi
Journal:  Sci Rep       Date:  2021-02-01       Impact factor: 4.379

5.  Dosimetry of heavy ion exposure to human cells using nanoscopic imaging of double strand break repair protein clusters.

Authors:  Judith Reindl; P Kundrat; S Girst; M Sammer; B Schwarz; G Dollinger
Journal:  Sci Rep       Date:  2022-01-25       Impact factor: 4.996

6.  Dosimetric Validation of a System to Treat Moving Tumors Using Scanned Ion Beams That Are Synchronized With Anatomical Motion.

Authors:  Michelle Lis; Wayne Newhauser; Marco Donetti; Moritz Wolf; Timo Steinsberger; Athena Paz; Christian Graeff
Journal:  Front Oncol       Date:  2021-09-08       Impact factor: 6.244

7.  A method for time-independent film dosimetry: Can we obtain accurate patient-specific QA results at any time postirradiation?

Authors:  Leon Dunn; Guy Godwin; James Hellyer; Xiaolei Xu
Journal:  J Appl Clin Med Phys       Date:  2022-01-20       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.