Literature DB >> 20304723

A new optical-CT apparatus for 3-D radiotherapy dosimetry: is free space scanning feasible?

Antonios E Papadakis1, Giannis Zacharakis, Thomas G Maris, Jorge Ripoll, John Damilakis.   

Abstract

In this paper, we present a new optical computed tomography (Optical-CT) scanner for the verification of the radiation dose schemes delivered in modern radiotherapy applications. The optical-CT scanner is capable of providing rapid relative 3-D dosimetry with high spatial resolution with the use of normoxic N-Vinylpyrrolidone based polymer gel dosimeter. The scanner employs a diffuse uncollimated light illumination beam, a computer controlled motorized rotation stage and a charge-coupled device (CCD) camera. Various test experiments were performed to determine the performance characteristics of the optical-CT apparatus. Attenuation coefficient (micro) versus dose calibration data were generated from two calibration experiments using gel containers of two different diameters. All irradiations were performed using a 6 MV linear accelerator. A comparison of the reconstructed images between optical-CT scans using refractive index (RI) matching fluid and corresponding scans performed in free space was demonstrated. The dose readout of a test irradiation model was found to be in good agreement with independent readout performed by MR imaging. The findings presented in this study suggest that polymer dosimeters combined with the new optical-CT scanner constitute a potentially feasible method capable of measuring complex 3-D dose distributions with high resolution and in a wide dose range.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20304723     DOI: 10.1109/TMI.2010.2044800

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  How effective can optical-CT 3D dosimetry be without refractive fluid matching?

Authors:  L Rankine
Journal:  J Phys Conf Ser       Date:  2013

2.  Investigations into the feasibility of optical-CT 3D dosimetry with minimal use of refractively matched fluids.

Authors:  Kelsey Chisholm; Devin Miles; Leith Rankine; Mark Oldham
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

3.  On the feasibility of optical-CT imaging in media of different refractive index.

Authors:  Leith Rankine; Mark Oldham
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

4.  Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry.

Authors:  Asghar Mesbahi; Vahid Jafarzadeh; Nahideh Gharehaghaji
Journal:  Rep Pract Oncol Radiother       Date:  2012-04-17

5.  Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid.

Authors:  Steven Bache; Javian Malcolm; John Adamovics; Mark Oldham
Journal:  PLoS One       Date:  2016-03-28       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.