Literature DB >> 17473358

Initial investigation of a novel light-scattering gel phantom for evaluation of optical CT scanners for radiotherapy gel dosimetry.

Stephen Bosi1, Pourandokht Naseri, Alicia Puran, Justin Davies, Clive Baldock.   

Abstract

There is a need for stable gel materials for phantoms used to validate optical computerized tomography (CT) scanners used in conjunction with radiation-induced polymerizing gel dosimeters. Phantoms based on addition of light-absorbing dyes to gelatine to simulate gel dosimeters have been employed. However, to more accurately simulate polymerizing gels one requires phantoms that employ light-scattering colloidal suspensions added to the gel. In this paper, we present the initial results of using an optical CT scanner to evaluate a novel phantom in which radiation-exposed polymer gels are simulated by the addition of colloidal suspensions of varying turbidity. The phantom may be useful as a calibration transfer standard for polymer gel dosimeters. The tests reveal some phenomena peculiar to light-scattering gels that need to be taken into account when calibrating polymer gel dosimeters.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17473358     DOI: 10.1088/0031-9155/52/10/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  How effective can optical-CT 3D dosimetry be without refractive fluid matching?

Authors:  L Rankine
Journal:  J Phys Conf Ser       Date:  2013

Review 2.  Optical and x-ray technology synergies enabling diagnostic and therapeutic applications in medicine.

Authors:  Brian W Pogue; Brian C Wilson
Journal:  J Biomed Opt       Date:  2018-10       Impact factor: 3.170

3.  On the need for comprehensive validation of deformable image registration, investigated with a novel 3-dimensional deformable dosimeter.

Authors:  Titania Juang; Shiva Das; John Adamovics; Ron Benning; Mark Oldham
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-07-23       Impact factor: 7.038

Review 4.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

5.  Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry.

Authors:  Timothy Olding; Oliver Holmes; Paul Dejean; Kim B McAuley; Ken Nkongchu; Giles Santyr; L John Schreiner
Journal:  J Med Phys       Date:  2011-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.