Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip.

Mehdi Moini1.   

Abstract

A robust, reproducible, and single-step interface design between low flow rate separation techniques, such as sheathless capillary electrophoresis (CE) and nanoliquid chromatography (nLC), and mass spectrometry (MS) using electrospray ionization (ESI), is introduced. In this design, the electrical connection to the capillary outlet was achieved through a porous tip at the capillary outlet. The porous section was created by removing 1-1.5 in. of the polyimide coating of the capillary and etching this section by 49% solution of HF until it is porous. The electrical connection to the capillary outlet is achieved simply by inserting the capillary outlet containing the porous tip into the existing ESI needle (metal sheath) and filling the needle with the background electrolyte. Redox reactions of water at the ESI needle and transport of these small ions through the porous tip into the capillary provides the electrical connection for the ESI and for the CE outlet electrode. The etching process reduces the wall thickness of the etched section, including the tip of the capillary, to 5-10 microm, which for a 20-30 microm i.d. capillary results in stable electrospray at approximately 1.5 kV. The design is suitable for interfacing a wide range of capillary sizes with a wide range of flow rates to MS via ESI, but it is especially useful for interfacing narrow (<30 microm i.d.) capillaries and low flow rates (<100 nL/min). The advantages of the porous tip design include the following: (1) its fabrication is reproducible, can be automated, and does not require any mechanical tools. (2) The etching process reduces the tip outer diameter and makes the capillary porous in one step. (3) The interface can be used for both nLC-MS and CE-MS. (4) If blocked or damaged, a small section of the tip can be etched off without any loss of performance. (5) The interface design leaves the capillary inner wall intact and, therefore, does not add any dead volume to the CE-MS or nLC-MS interface. (6) Bubble formation due to redox reactions of water at the high-voltage electrode is outside of the separation capillary and does not affect separation or MS performances. The performance of this interface is demonstrated by the analyses of amino acids, peptide, and protein mixtures.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17447730     DOI: 10.1021/ac0704560

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  75 in total

1.  Portable, Battery Operated Capillary Electrophoresis with Optical Isomer Resolution Integrated with Ionization Source for Mass Spectrometry.

Authors:  Mehdi Moini; Christopher M Rollman
Journal:  J Am Soc Mass Spectrom       Date:  2015-12-07       Impact factor: 3.109

2.  Training in metabolomics research. I. Designing the experiment, collecting and extracting samples and generating metabolomics data.

Authors:  Stephen Barnes; H Paul Benton; Krista Casazza; Sara J Cooper; Xiangqin Cui; Xiuxia Du; Jeffrey Engler; Janusz H Kabarowski; Shuzhao Li; Wimal Pathmasiri; Jeevan K Prasain; Matthew B Renfrow; Hemant K Tiwari
Journal:  J Mass Spectrom       Date:  2016-07       Impact factor: 1.982

3.  Comparing and combining capillary electrophoresis electrospray ionization mass spectrometry and nano-liquid chromatography electrospray ionization mass spectrometry for the characterization of post-translationally modified histones.

Authors:  Bettina Sarg; Klaus Faserl; Leopold Kremser; Bernhard Halfinger; Roberto Sebastiano; Herbert H Lindner
Journal:  Mol Cell Proteomics       Date:  2013-05-29       Impact factor: 5.911

4.  Capillary Zone Electrophoresis-Tandem Mass Spectrometry for Large-Scale Phosphoproteomics with the Production of over 11,000 Phosphopeptides from the Colon Carcinoma HCT116 Cell Line.

Authors:  Daoyang Chen; Katelyn R Ludwig; Oleg V Krokhin; Vic Spicer; Zhichang Yang; Xiaojing Shen; Amanda B Hummon; Liangliang Sun
Journal:  Anal Chem       Date:  2019-01-23       Impact factor: 6.986

5.  Capillary electrophoresis coupled to negative mode electrospray ionization-mass spectrometry using an electrokinetically-pumped nanospray interface with primary amines grafted to the interior of a glass emitter.

Authors:  Scott A Sarver; Nicole M Schiavone; Jennifer Arceo; Elizabeth H Peuchen; Zhenbin Zhang; Liangliang Sun; Norman J Dovichi
Journal:  Talanta       Date:  2017-01-03       Impact factor: 6.057

Review 6.  Recent advances in coupling capillary electrophoresis-based separation techniques to ESI and MALDI-MS.

Authors:  Xuefei Zhong; Zichuan Zhang; Shan Jiang; Lingjun Li
Journal:  Electrophoresis       Date:  2013-12-05       Impact factor: 3.535

7.  Ultrasensitive and fast bottom-up analysis of femtogram amounts of complex proteome digests.

Authors:  Liangliang Sun; Guijie Zhu; Yimeng Zhao; Xiaojing Yan; Si Mou; Norman J Dovichi
Journal:  Angew Chem Int Ed Engl       Date:  2013-10-31       Impact factor: 15.336

Review 8.  Identification and Quantification of Proteoforms by Mass Spectrometry.

Authors:  Leah V Schaffer; Robert J Millikin; Rachel M Miller; Lissa C Anderson; Ryan T Fellers; Ying Ge; Neil L Kelleher; Richard D LeDuc; Xiaowen Liu; Samuel H Payne; Liangliang Sun; Paul M Thomas; Trisha Tucholski; Zhe Wang; Si Wu; Zhijie Wu; Dahang Yu; Michael R Shortreed; Lloyd M Smith
Journal:  Proteomics       Date:  2019-05       Impact factor: 3.984

9.  Stable, reproducible, and automated capillary zone electrophoresis-tandem mass spectrometry system with an electrokinetically pumped sheath-flow nanospray interface.

Authors:  Guijie Zhu; Liangliang Sun; Xiaojing Yan; Norman J Dovichi
Journal:  Anal Chim Acta       Date:  2013-12-07       Impact factor: 6.558

Review 10.  Capillary zone electrophoresis as a tool for bottom-up protein analysis.

Authors:  Roza Wojcik; Guijie Zhu; Zhenbin Zhang; Xiaojing Yan; Yimeng Zhao; Liangliang Sun; Matthew M Champion; Norman J Dovichi
Journal:  Bioanalysis       Date:  2015-12-10       Impact factor: 2.681

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.