Literature DB >> 24436732

Use of 3-d plate in displaced angle fracture of mandible.

Uma Shanker Pal1, R K Singh1, Satish Dhasmana2, Somdipto Das1, Sanjib K Das1.   

Abstract

Introduction Mandibular angle fractures can be treated by various methods, but even the most popular methods may not be able to give satisfactory results, as the pterygomasseteric sling and masticatory forces can result in displaced angle fracture. These displaced fragments cannot be satisfactorily retained by single miniplate fixation. The aim of this study is to assess treatment of displaced angle fracture with 3-D miniplate fixation. This study can also be considered as a therapeutic study with level V evidence. Materials and Methods This study was designed to assess the feasibility of 3-D matrix miniplate fixation in displaced angle fractures. Eighteen patients with displaced angle fractures were included in this study. Matrix miniplate fixation was done transorally under general anesthesia. Results All these cases were treated successfully, and common complications like infection (5.5% of patients), wound dehiscence (11%), paresthesia (16.7%), and malocclusion (11%) were observed in our study. Conclusions Three-dimensional miniplate fixation in displaced angle fractures provides better stability and function.

Entities:  

Keywords:  mandibular angle fracture; matrix miniplate; osteosynthesis

Year:  2013        PMID: 24436732      PMCID: PMC3699239          DOI: 10.1055/s-0032-1332211

Source DB:  PubMed          Journal:  Craniomaxillofac Trauma Reconstr        ISSN: 1943-3875


  13 in total

1.  [Cortical thickness of the mandible with special reference to miniplate osteosynthesis. Morphometric analysis of autopsy material].

Authors:  H Heibel; K W Alt; R Wächter; W Bähr
Journal:  Mund Kiefer Gesichtschir       Date:  2001-05

2.  Biomechanical evaluation of new fixation devices for mandibular angle fractures.

Authors:  J M Wittenberg; D P Mukherjee; B R Smith; R N Kruse
Journal:  Int J Oral Maxillofac Surg       Date:  1997-02       Impact factor: 2.789

3.  Solitary lag screw osteosynthesis in the treatment of fractures of the angle of the mandible: a retrospective study.

Authors:  H Niederdellmann; V Shetty
Journal:  Plast Reconstr Surg       Date:  1987-07       Impact factor: 4.730

4.  Use of rectangular grid miniplates for fracture fixation at the mandibular angle.

Authors:  Eduardo Hochuli-Vieira; Thi Khanh Linh Ha; Valfrido Antonio Pereira-Filho; Constantin Alexander Landes
Journal:  J Oral Maxillofac Surg       Date:  2011-01-08       Impact factor: 1.895

5.  Comparison of 3-dimensional and standard miniplate fixation in the management of mandibular fractures.

Authors:  Manoj Kumar Jain; K S Manjunath; B K Bhagwan; Dipit K Shah
Journal:  J Oral Maxillofac Surg       Date:  2010-04-22       Impact factor: 1.895

6.  Fixation of mandibular angle fractures with a 2.0-mm 3-dimensional curved angle strut plate.

Authors:  Claude Guimond; James V Johnson; Jose M Marchena
Journal:  J Oral Maxillofac Surg       Date:  2005-02       Impact factor: 1.895

7.  Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle.

Authors:  Juergen Zix; Olivier Lieger; Tateyuki Iizuka
Journal:  J Oral Maxillofac Surg       Date:  2007-09       Impact factor: 1.895

8.  New innovations in craniomaxillofacial fixation: the 2.0 lock system.

Authors:  Brian Alpert; Rolf Gutwald; Rainer Schmelzeisen
Journal:  Keio J Med       Date:  2003-06

9.  Stability testing of a two miniplate fixation technique for mandibular angle fractures. An in vitro study.

Authors:  B H Choi; J H Yoo; K N Kim; H S Kang
Journal:  J Craniomaxillofac Surg       Date:  1995-04       Impact factor: 2.078

10.  Monocortical miniplate fixation of mandibular angle fractures.

Authors:  F E Levy; R W Smith; R M Odland; L J Marentette
Journal:  Arch Otolaryngol Head Neck Surg       Date:  1991-02
View more
  6 in total

1.  Management of Angle Mandible Fractures by 3D Rectangular Grid Plate: A Prospective Study.

Authors:  Ramisetti Sudheer; Bathini Dilip Chakravarthy; Nandagopal Vura; Gaddipati Rajasekhar
Journal:  J Maxillofac Oral Surg       Date:  2019-09-17

2.  The Efficacy of Fixation of Unilateral Mandibular Angle Fracture with Single 3D Plate vs Single Miniplate Using Transbuccal Approach.

Authors:  Nancy Mathew; Inderjot Singh; Sumir Gandhi; Manisha Solanki; Navpreet Singh Bedi
Journal:  J Maxillofac Oral Surg       Date:  2020-10-19

3.  Management of mandibular angle fractures using a 1.7 mm 3-dimensional strut plate.

Authors:  Varnika Pandey; Ongkila Bhutia; Shakil Ahmed Nagori; Ashu Seith; Ajoy Roychoudhury
Journal:  J Oral Biol Craniofac Res       Date:  2015-11-27

4.  3-D Miniplates Versus Conventional Miniplates in Treatment of Mandible Fractures.

Authors:  Niranjan Mishra; Nirav Thakkar; Indubhusan Kar; Shadab Ali Baig; Gaurav Sharma; Rosalin Kar; Gyana Ranjan Sahu; Krishna Gopal Birmiwal
Journal:  J Maxillofac Oral Surg       Date:  2017-12-14

5.  Role of fixation in posttraumatic nerve injury recovery in displaced mandibular angle fracture.

Authors:  R K Singh; U S Pal; Pranshu Singh; Geeta Singh
Journal:  Natl J Maxillofac Surg       Date:  2016 Jan-Jun

6.  Routine removal of the plate after surgical treatment for mandibular angle fracture with a third molar in relation to the fracture line.

Authors:  Kazuhiko Yamamoto; Yumiko Matsusue; Satoshi Horita; Kazuhiro Murakami; Tsutomu Sugiura; Tadaaki Kirita
Journal:  Ann Maxillofac Surg       Date:  2015 Jan-Jun
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.