Literature DB >> 24420697

4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines.

Yugang Min1, John Neylon, Amish Shah, Sanford Meeks, Percy Lee, Patrick Kupelian, Anand P Santhanam.   

Abstract

PURPOSE: The accuracy of 4D-CT registration is limited by inconsistent Hounsfield unit (HU) values in the 4D-CT data from one respiratory phase to another and lower image contrast for lung substructures. This paper presents an optical flow and thin-plate spline (TPS)-based 4D-CT registration method to account for these limitations.
METHODS: The use of unified HU values on multiple anatomy levels (e.g., the lung contour, blood vessels, and parenchyma) accounts for registration errors by inconsistent landmark HU value. While 3D multi-resolution optical flow analysis registers each anatomical level, TPS is employed for propagating the results from one anatomical level to another ultimately leading to the 4D-CT registration. 4D-CT registration was validated using target registration error (TRE), inverse consistency error (ICE) metrics, and a statistical image comparison using Gamma criteria of 1 % intensity difference in 2 mm(3) window range.
RESULTS: Validation results showed that the proposed method was able to register CT lung datasets with TRE and ICE values <3 mm. In addition, the average number of voxel that failed the Gamma criteria was <3 %, which supports the clinical applicability of the propose registration mechanism.
CONCLUSION: The proposed 4D-CT registration computes the volumetric lung deformations within clinically viable accuracy.

Entities:  

Mesh:

Year:  2014        PMID: 24420697     DOI: 10.1007/s11548-013-0975-7

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  24 in total

1.  A GPU-based framework for modeling real-time 3D lung tumor conformal dosimetry with subject-specific lung tumor motion.

Authors:  Yugang Min; Anand Santhanam; Harini Neelakkantan; Bari H Ruddy; Sanford L Meeks; Patrick A Kupelian
Journal:  Phys Med Biol       Date:  2010-08-16       Impact factor: 3.609

2.  Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry.

Authors:  Gary E Christensen; Joo Hyun Song; Wei Lu; Issam El Naqa; Daniel A Low
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

3.  Real-time simulation of 4D lung tumor radiotherapy using a breathing model.

Authors:  Anand P Santhanam; Twyla Willoughby; Amish Shah; Sanford Meeks; Jannick P Rolland; Patrick Kupelian
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

4.  Verification of four-dimensional photon dose calculations.

Authors:  Yevgeniy Y Vinogradskiy; Peter Balter; David S Followill; Paola E Alvarez; R Allen White; George Starkschall
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

Review 5.  American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning.

Authors:  B Fraass; K Doppke; M Hunt; G Kutcher; G Starkschall; R Stern; J Van Dyke
Journal:  Med Phys       Date:  1998-10       Impact factor: 4.071

6.  Evaluation of registration methods on thoracic CT: the EMPIRE10 challenge.

Authors:  Keelin Murphy; Bram van Ginneken; Joseph M Reinhardt; Sven Kabus; Kai Ding; Xiang Deng; Kunlin Cao; Kaifang Du; Gary E Christensen; Vincent Garcia; Tom Vercauteren; Nicholas Ayache; Olivier Commowick; Grégoire Malandain; Ben Glocker; Nikos Paragios; Nassir Navab; Vladlena Gorbunova; Jon Sporring; Marleen de Bruijne; Xiao Han; Mattias P Heinrich; Julia A Schnabel; Mark Jenkinson; Cristian Lorenz; Marc Modat; Jamie R McClelland; Sébastien Ourselin; Sascha E A Muenzing; Max A Viergever; Dante De Nigris; D Louis Collins; Tal Arbel; Marta Peroni; Rui Li; Gregory C Sharp; Alexander Schmidt-Richberg; Jan Ehrhardt; René Werner; Dirk Smeets; Dirk Loeckx; Gang Song; Nicholas Tustison; Brian Avants; James C Gee; Marius Staring; Stefan Klein; Berend C Stoel; Martin Urschler; Manuel Werlberger; Jef Vandemeulebroucke; Simon Rit; David Sarrut; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2011-05-31       Impact factor: 10.048

7.  Technical note: DIRART--A software suite for deformable image registration and adaptive radiotherapy research.

Authors:  Deshan Yang; Scott Brame; Issam El Naqa; Apte Aditya; Yu Wu; S Murty Goddu; Sasa Mutic; Joseph O Deasy; Daniel A Low
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

8.  Nonrigid registration method to assess reproducibility of breath-holding with ABC in lung cancer.

Authors:  David Sarrut; Vlad Boldea; Myriam Ayadi; Jean-Noël Badel; Chantal Ginestet; Sébastien Clippe; Christian Carrie
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-02-01       Impact factor: 7.038

9.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

10.  Validation of three deformable image registration algorithms for the thorax.

Authors:  Kujtim Latifi; Geoffrey Zhang; Marnix Stawicki; Wouter van Elmpt; Andre Dekker; Kenneth Forster
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

View more
  2 in total

1.  Initial clinical observations of intra- and interfractional motion variation in MR-guided lung SBRT.

Authors:  David H Thomas; Anand Santhanam; Amar U Kishan; Minsong Cao; James Lamb; Yugang Min; Dylan O'Connell; Yingli Yang; Nzhde Agazaryan; Percy Lee; Daniel Low
Journal:  Br J Radiol       Date:  2018-01-22       Impact factor: 3.039

2.  Contour propagation using non-uniform cubic B-splines for lung tumor delineation in 4D-CT.

Authors:  Yongchuan Liu; Renchao Jin; Mi Chen; Enmin Song; Xiangyang Xu; Sheng Zhang; Chih-Cheng Hung
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-07-16       Impact factor: 2.924

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.