| Literature DB >> 24410918 |
Hossein Gholizadeh1, Noor Azuan Abu Osman, Arezoo Eshraghi, Sadeeq Ali, Nooranida Arifin, Wan Abu Bakar Wan Abas.
Abstract
BACKGROUND: Good prosthetic suspension system secures the residual limb inside the prosthetic socket and enables easy donning and doffing. This study aimed to introduce, evaluate and compare a newly designed prosthetic suspension system (HOLO) with the current suspension systems (suction, pin/lock and magnetic systems).Entities:
Mesh:
Year: 2014 PMID: 24410918 PMCID: PMC3898787 DOI: 10.1186/1475-925X-13-1
Source DB: PubMed Journal: Biomed Eng Online ISSN: 1475-925X Impact factor: 2.819
Figure 1Fabrication process of new system (Hook and Loop system).
Figure 2The prosthetic suspension systems used in this study: A (Seal-In X5), B (Pin/Lock system), C (Magnetic system), D (Hook and Loop); E (Mechanical testing under tensile loading).
Characteristics of the participants
| 1 | 39 | 170 | 65 | TT | Trauma | 5 | 14 | K4 | Bony and conical in shape. The bony end of the residual limb was painful during the swing phase of gait. He was using pin/lock system prior to the study. |
| 2 | 23 | 167 | 82 | TT | Trauma | 3 | 15 | K3 | Cylindrical in shape. He was using PTB socket with Pelite (soft liner). He encountered numerous problems with prosthesis, such as pain, wound at the end of his stump and too much movement (pistoning) within the socket. Most of the weight was centralized at the end of the socket. |
| 3 | 51 | 172 | 67 | TT | Trauma | 5 | 14 | K3 | Bony and conical in shape. The bony end of the residual limb and fibular head were painful during the swing phase of gait and while wearing the prosthesis. He was using pin/lock system prior to the study. |
| 4 | 40 | 180 | 95 | TT | Diabetes | 7 | 16 | K2 | Cylindrical in shape. He was using pin/lock system prior to the study. He encountered difficulties in aligning the pin during wearing the prosthesis. He experienced a disorder in his left hand. |
| 5 | 75 | 182 | 75 | TT | Diabetes | 8 | 13 | K2 | Bony and conical in shape. The bony end of the residual limb was painful during the swing phase of gait. He was using pin/lock system prior to the study. |
| 6 | 45 | 185 | 84 | TT | Trauma | 26 | 12 | K3 | Short stump. He was using PTB socket with Pelite (soft liner). He had pain at the end of stump and too much movement (pistoning) within the socket. Most of his weight was centralized at the end of the socket. |
| 7 | 41 | 173 | 95 | TT | Trauma | 5 | 14 | K3 | Cylindrical in shape. He was using pin/lock system prior to the study. He did not have any problem with his prosthesis. |
| 8 | 34 | 175 | 78 | TT | Trauma | 10 | 28 | K3 | Cylindrical in shape. He did not feel any pain at the stump. He was using pin/lock system prior to the study. |
| 9 | 32 | 163 | 72 | TT | Trauma | 18 | 25 | K2 | Conical in shape. Bony prominence was evident at the end of his stump. He did not feel any pain at the stump. He was using pin/lock system prior to the study. |
Figure 3Donning and doffing procedures.
Figure 4Subject 1 used the new system for walking (A), cycling (B) and running (C).
Subjective feedback of the participants
| 1 | Seal-In | 1 | K4 | He did not feel any pain at the distal of his residual limb with the Seal-In and the new suspension system during walking. He experienced more confidence and also stated that the Seal-In was more suitable than the other suspension systems. While removing the prosthesis was more challenging, he preferred to use the seal-in system. |
| Pin/Lock | 4 | |||
| Magnetic | 2 | |||
| Hook/Loop | 3 | |||
| 2 | Seal-In | 4 | K3 | He was more satisfied with the silicone liners compared to the PTB with Pelite liner. After changing to silicone liner (TSB socket), he did not have pain at the distal end of the residual limb, and the wound was healed after two weeks. He felt more confident with the silicone liner and different lock systems (pin/lock, magnet or HOLO). Among the four systems in this study, he preferred the HOLO, the magnetic system, and the pin/lock system. |
| Pin/Lock | 3 | |||
| Magnetic | 2 | |||
| Hook/Loop | 1 | |||
| 3 | Seal-In | 4 | K3 | He did not feel any pain at the distal of residual limb with the seal-in and the new suspension system. However, he had pain during donning and doffing with the seal-In liner. He stated that the seal-in was more suitable during walking, but wearing and removing the prosthesis was extremely more difficult compared to the other suspension systems. |
| Pin/Lock | 3 | |||
| Magnetic | 1 | |||
| Hook/Loop | 2 | |||
| 4 | Seal-In | 4 | K2 | It was very difficult to use the seal-In due to upper limb weakness; he preferred the hook and loop, pin/lock and magnetic systems mostly due to easy donning and doffing. |
| Pin/Lock | 2 | |||
| Magnetic | 3 | |||
| Hook/Loop | 1 | |||
| 5 | Seal-In | 4 | K2 | He did not feel pain with the seal-in and the new suspension system. Nevertheless, he preferred the new suspension system due to its advantages of easy donning and doffing. He was not happy with the tearing noise during doffing the prosthesis. |
| Pin/Lock | 3 | |||
| Magnetic | 2 | |||
| Hook/Loop | 1 | |||
| 6 | Seal-In | 4 | K3 | Pain at the end of the socket was less with the TSB socket compared to the PTB socket. He was satisfied with the pin/lock, hook/loop and magnetic systems while he felt more socket fit and less rotation inside the socket with the seal-in. He mentioned that he is not going to use the seal-in due to the difficulty in donning and doffing. |
| Pin/Lock | 1 | |||
| Magnetic | 3 | |||
| Hook/Loop | 2 | |||
| 7 | Seal-In | 3 | K3 | He felt more socket fit and higher confidence with the seal-in during walking but he was not satisfied with the donning and doffing procedures. He preferred to use the pin/lock and magnetic systems. He was not happy with the hook/lop system due to the sound developed during doffing the prosthesis. |
| Pin/Lock | 1 | |||
| Magnetic | 2 | |||
| Hook/Loop | 4 | |||
| 8 | Seal-In | 4 | K3 | He was happier with the pin/lock and HOLO systems due to easy donning and doffing procedures. Also, he felt less traction at the end of the socket with HOLO and seal-in system. |
| Pin/Lock | 1 | |||
| Magnetic | 3 | |||
| Hook/Loop | 2 | |||
| 9 | Seal-In | 4 | K2 | He felt more comfortable at the distal end with the seal-in and the new suspension system, and he was more confident during walking. Regarding the donning and doffing, he preferred the pin/lock and HOLO system. He chose the pin/lock as his first choice due to easy donning and doffing. |
| Pin/Lock | 1 | |||
| Magnetic | 3 | |||
| Hook/Loop | 2 | |||
Satisfaction and problems with different suspension systems
| Fitting | Pin/lock | 75.59 | Holo | Pin/lock | .125 |
| Seal-In (suction) | 87.09 | Seal-In (suction) | .002* | ||
| Magnetic | 76.84 | Magnetic | .181 | ||
| Holo | 80.50 | | | ||
| Donning/ Doffing | Pin/lock | 71.10 | Holo | Pin/lock | .002* |
| Seal-In (suction) | 57.89 | Seal-In (suction) | .000* | ||
| Magnetic | 79.65 | Magnetic | .080 | ||
| Holo | 83.30 | | | ||
| Sitting | Pin/lock | 79.40 | Holo | Pin/lock | .767 |
| Seal-In (suction) | 79.45 | Seal-In (suction) | .666 | ||
| Magnetic | 78.40 | Magnetic | .360 | ||
| Holo | 80.20 | | | ||
| Walking | Pin/lock | 77.10 | Holo | Pin/lock | .089 |
| Seal-In (suction) | 78.30 | Seal-In (suction) | .906 | ||
| Magnetic | 79.03 | Magnetic | .452 | ||
| Holo | 78.50 | | | ||
| Walking (uneven surface) | Pin/lock | 75.00 | Holo | Pin/lock | .415 |
| Seal-In (suction) | 76.80 | Seal-In (suction) | .771 | ||
| Magnetic | 77.80 | Magnetic | .152 | ||
| Holo | 76.10 | | | ||
| Walking (stairs) | Pin/lock | 75.40 | Holo | Pin/lock | .102 |
| Seal-In (suction) | 77.63 | Seal-In (suction) | .773 | ||
| Magnetic | 78.20 | Magnetic | .588 | ||
| Holo | 77.30 | | | ||
| Sweating | Pin/lock | 67.83 | Holo | Pin/lock | .106 |
| Seal-In (suction) | 65.30 | Seal-In (suction) | .308 | ||
| Magnetic | 63.40 | Magnetic | .950 | ||
| Holo | 63.30 | | | ||
| Pistoning | Pin/lock | 84.13 | Holo | Pin/lock | .020* |
| Seal-In (suction) | 96.40 | Seal-In (suction) | .000* | ||
| Magnetic | 78.80 | Magnetic | .681 | ||
| Holo | 79.30 | | | ||
| Rotation | Pin/lock | 80.19 | Holo | Pin/lock | .002* |
| Seal-In (suction) | 99.50 | Seal-In (suction) | .000* | ||
| Magnetic | 82.09 | Magnetic | .172 | ||
| Holo | 83.50 | | | ||
| Swelling | Pin/lock | 85.89 | Holo | Pin/lock | .800 |
| Seal-In (suction) | 88.50 | Seal-In (suction) | .080 | ||
| Magnetic | 83.63 | Magnetic | .173 | ||
| Holo | 85.50 | | | ||
| Smell | Pin/lock | 84.70 | Holo | Pin/lock | .569 |
| Seal-In (suction) | 83.10 | Seal-In (suction) | .298 | ||
| Magnetic | 84.60 | Magnetic | .745 | ||
| Holo | 85.40 | | | ||
| Sound | Pin/lock | 70.30 | Holo | Pin/lock | .218 |
| Seal-In (suction) | 96.50 | Seal-In (suction) | .000* | ||
| Magnetic | 80.15 | Magnetic | .000* | ||
| Holo | 66.90 | | | ||
| Pain | Pin/lock | 76.30 | Holo | Pin/lock | .000* |
| Seal-In (suction) | 80.65 | Seal-In (suction) | .003* | ||
| Magnetic | 86.70 | Magnetic | .723 | ||
| Holo | 87.40 | | | ||
| Overall satisfaction | Pin/lock | 83.40 | Holo | Pin/lock | .643 |
| Seal-In (suction) | 64.60 | Seal-In (suction) | .000* | ||
| Magnetic | 79.60 | Magnetic | .672 | ||
| Holo | 80.20 | ||||
*Significant differences.