Literature DB >> 16466153

A questionnaire survey of the effect of different interface types on patient satisfaction and perceived problems among trans-tibial amputees.

F B Van de Weg1, D A W M Van der Windt.   

Abstract

The objectives were to investigate the effect of three different interface types on consumer satisfaction and perceived problems among trans-tibial amputees in the Netherlands. A postal questionnaire (based on the Prosthesis Evaluation Questionnaire) was sent to 353 patients. Responders were classified in three groups of interface types: polyethylene foam (PEF) inserts, silicone liners (SIL), and polyurethane liners (PUL). Differences concerning satisfaction and problems between interface types were computed and adjusted for potential confounding by age, gender, reason for amputation and time since first prosthesis. A total of 220 patients responded (62%). Patients wearing liners reported a significantly poorer durability and higher maintenance time compared with patients using PEF inserts. Sum-scores for satisfaction or problems did not show any significant differences between groups. Analysis of individual items showed a significant difference only for satisfaction with sitting and with walking on uneven terrain in favour of PEF inserts. In contrast to most studies, interface type was included as a possible determinant of customer use, satisfaction, and perceived problems. The perceived differences between the three suspension types are to a large extent small and non-significant. The findings do not support liner prescription as a matter of course for all trans-tibial amputees. A careful analysis of patients' preferences should be made to determine the best course of action. Further studies, preferably prospective, need to be conducted to determine which systems are most comfortable and offer least complaints.

Entities:  

Mesh:

Year:  2005        PMID: 16466153     DOI: 10.1080/03093640500199679

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  10 in total

Review 1.  Factors Influencing Functional Outcomes and Return-to-Work After Amputation: A Review of the Literature.

Authors:  Benjamin J Darter; Carolyn E Hawley; Amy J Armstrong; Lauren Avellone; Paul Wehman
Journal:  J Occup Rehabil       Date:  2018-12

2.  Use of an innovative model to evaluate mobility in seniors with lower-limb amputations of vascular origin: a pilot study.

Authors:  Claude Vincent; Emilie Demers; Hélène Moffet; Hélène Corriveau; Sylvie Nadeau; Catherine Mercier
Journal:  BMC Geriatr       Date:  2010-09-20       Impact factor: 3.921

3.  Elastomeric liners for people with transtibial amputation: Survey of prosthetists' clinical practices.

Authors:  Brian J Hafner; John C Cagle; Katheryn J Allyn; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2016-09-24       Impact factor: 1.895

4.  Evaluating the use of a thermoplastic socket in Kenya: A pilot study.

Authors:  Giulia Barbareschi; Wesley Teerlink; Josepg Gakunga Njuguna; Purity Musungu; Mary Dama Kirino; Catherine Holloway
Journal:  Prosthet Orthot Int       Date:  2022-03-25       Impact factor: 1.672

5.  Evaluation of new suspension system for limb prosthetics.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Sadeeq Ali; Nooranida Arifin; Wan Abu Bakar Wan Abas
Journal:  Biomed Eng Online       Date:  2014-01-10       Impact factor: 2.819

6.  Clinical implication of interface pressure for a new prosthetic suspension system.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Nasrul Anuar Abd Razak
Journal:  Biomed Eng Online       Date:  2014-06-30       Impact factor: 2.819

7.  Comparative study between Dermo, Pelite, and Seal-In X5 liners: effect on patient's satisfaction and perceived problems.

Authors:  Sadeeq Ali; Noor Azuan Abu Osman; Nooranida Arifin; Hossein Gholizadeh; Nasrul Anwar Abd Razak; Wan Abu Bakar Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-11

Review 8.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13

Review 9.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

Review 10.  Prosthesis satisfaction in lower limb amputees: A systematic review of associated factors and questionnaires.

Authors:  Erwin C Baars; Ernst Schrier; Pieter U Dijkstra; Jan H B Geertzen
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.889

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.