Comparison of interface pressures with pin and suction suspension systems.

Tracy L Beil1, Glenn M Street.   

Abstract

A common mode of limb suspension for transtibial amputees is the pin liner/shuttle lock system. Despite its popularity, some clinicians question its use because of observed daily and chronic changes to the residual limb. For this study, we measured limb interface pressures during ambulation with pin and suction suspension systems. No pressure differences were seen between the modes of suspension during stance phase. However, during swing phase, pin suspension maintained an average occlusive compressive pressure of 6.7 kPa on the proximal tissues, as compared to the subocclusive pressure of 1.1 kPa with suction suspension. Simultaneously, pin suspension elevated the peak magnitude of suction to -39.5 kPa at the distal residual limb, compared to -26.1 kPa with suction suspension. During swing phase, the pin liner squeezes proximally while creating a large suction distally on the residual limb and is the likely cause of daily and chronic skin changes observed in pin users.

Entities:  

Mesh:

Year:  2004        PMID: 15685470     DOI: 10.1682/jrrd.2003.09.0146

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  10 in total

1.  Evaluation of Force Sensing Resistors for the Measurement of Interface Pressures in Lower Limb Prosthetics.

Authors:  Eric Swanson; Ethan Weathersby; John Cagle; Joan E Sanders
Journal:  J Biomech Eng       Date:  2019-04-24       Impact factor: 2.097

2.  Instrumented socket inserts for sensing interaction at the limb-socket interface.

Authors:  Eric C Swanson; Jake B McLean; Katheryn J Allyn; Christian B Redd; Joan E Sanders
Journal:  Med Eng Phys       Date:  2017-12-08       Impact factor: 2.242

3.  Vacuum level effects on gait characteristics for unilateral transtibial amputees with elevated vacuum suspension.

Authors:  Hang Xu; Kasey Greenland; Donald Bloswick; Jie Zhao; Andrew Merryweather
Journal:  Clin Biomech (Bristol, Avon)       Date:  2017-02-14       Impact factor: 2.063

4.  Self-reported socket comfort, mobility, and balance-confidence of individuals with transtibial amputation using pinlock vs suction suspension.

Authors:  Mayank Seth; Emma Haldane Beisheim; Maximilian Tobias Spencer; John Robert Horne; Frank Bernard Sarlo; Jaclyn Megan Sions
Journal:  Prosthet Orthot Int       Date:  2021-06-01       Impact factor: 1.672

5.  Development and evaluation of new coupling system for lower limb prostheses with acoustic alarm system.

Authors:  Arezoo Eshraghi; Noor Azuan Abu Osman; Hossein Gholizadeh; Jalil Ahmadian; Bizhan Rahmati; Wan Abu Bakar Wan Abas
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

6.  Evaluation of new suspension system for limb prosthetics.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Sadeeq Ali; Nooranida Arifin; Wan Abu Bakar Wan Abas
Journal:  Biomed Eng Online       Date:  2014-01-10       Impact factor: 2.819

7.  Clinical implication of interface pressure for a new prosthetic suspension system.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Nasrul Anuar Abd Razak
Journal:  Biomed Eng Online       Date:  2014-06-30       Impact factor: 2.819

8.  Predictive prosthetic socket design: part 2-generating person-specific candidate designs using multi-objective genetic algorithms.

Authors:  J W Steer; P A Grudniewski; M Browne; P R Worsley; A J Sobey; A S Dickinson
Journal:  Biomech Model Mechanobiol       Date:  2019-11-18

9.  Development of an air pneumatic suspension system for transtibial prostheses.

Authors:  Gholamhossein Pirouzi; Noor Azuan Abu Osman; Azim Ataollahi Oshkour; Sadeeq Ali; Hossein Gholizadeh; Wan A B Wan Abas
Journal:  Sensors (Basel)       Date:  2014-09-09       Impact factor: 3.576

Review 10.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.