PURPOSE: The aim of the study reported here was to evaluate characteristics of the anterior-segment via anterior-segment optical coherence tomography (AS-OCT) and corneal biomechanical properties using an ocular response analyzer and their changes by peripheral laser iridotomy (PI) in patients with pigmentary glaucoma (PG).Entities:
Keywords: anterior-segment optical coherence tomography; corneal hysteresis; ocular response analyzer
Year: 2013 PMID: 24403816 PMCID: PMC3883583 DOI: 10.2147/OPTH.S53088
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Demographic characteristics (N=17)
| Characteristic | Baseline (± standard deviation) | After PI |
|---|---|---|
| Median age (range 31–51) (y) | 42 | (k) |
| Sex (male:female) | 17:0 | (k) |
| Pachymetry (μm) | 544±33 | (k) |
| Krukenberg’s spindle | 47% | (k) |
| Spherical equivalent (D) | −3.2±1.4 | (k) |
| Cup–disc ratio | 0.8±0.2 | (k) |
| Median BCVA (Snellen) | 20/25 | 20/25 |
| GAT | 15.0±4.2 | 13.2±2.3 |
| Treatments (n) | 0.7±0.9 | 0.9±0.8 |
Abbreviations: BCVA, best-corrected visual acuity (Snellen); D, diopter; GAT, Goldmann applanation tonometry; (k), unchanged; N, total number; n, category number; PI, peripheral laser iridotomy; y, years.
Figure 1Changes of the anterior chamber angles (transversal imaging) before (A) and after (B) peripheral laser iridotomy in the same eye.
Figure 2Box plot of anterior chamber angle values (°) before and after peripheral laser iridotomy (PI).
Note:P<0.001 in all four quadrants (paired Student’s t-test).
Figure 3Changes of anterior chamber volume (transversal imaging) before (A) and after (B) peripheral laser iridotomy in the same eye.
Figure 4Box plot of anterior chamber volume values (mm3) before and after peripheral laser iridotomy (PI).
Note:P<0.001 (paired Student’s t-test).
Biomechanical properties
| Property (mmHg) | Baseline ± standard deviation | After PI | Significance |
|---|---|---|---|
| IOPcc | 20.6±4.3 | 20.2±4.4 | 0.47 |
| IOPG | 19.3±4.8 | 18.9±5.3 | 0.35 |
| CH | 9.0±2.8 | 9.1±2.6 | 0.16 |
| CHcorr | 9.5±2.4 | 9.5±2.2 | 0.22 |
| CRF | 10.6±2.9 | 10.3±3.2 | 0.60 |
| CRFcorr | 10.2±2.7 | 10.0±2.7 | 0.25 |
| CHcorr – CRFcorr | −0.76±1.77 | −0.54±0.58 | 0.49 |
Abbreviations: CH, corneal hysteresis; CHcorr, corrected corneal hysteresis; CRF, corneal resistance factor; CRFcorr, corrected corneal resistance factor; IOPCC, corneal compensated intraocular pressure; IOPG, Goldmann-equivalent intraocular pressure; PI, peripheral laser iridotomy.
Figure 5Significant correlation between corrected baseline corneal hysteresis (CHcorr) and superior (A) and inferior (B) angles.
Note: Spearman’s rho P=0.553 and P=0.615 for superior and inferior angles, respectively.
Abbreviations: PI, peripheral laser iridotomy; CHcorr, corrected corneal hysteresis.
Regression model with baseline inferior angle as the dependent variable
| Model | Unstandardized coefficient
| Standardized coefficient
| Significance | ||
|---|---|---|---|---|---|
| B | SE | Beta | |||
| Constant | 7.40 | 17.70 | 0.42 | 0.68 | |
| CHcorr (mmHg) | 7.14 | 3.10 | 1.37 | 2.30 | 0.04 |
| Spherical equivalent (D) | −3.55 | 1.73 | −0.55 | −2.06 | 0.06 |
| Age (years) | 0.212 | 0.40 | 0.14 | 0.53 | 0.61 |
| CRFcorr (mmHg) | −4.02 | 2.47 | −0.96 | −1.63 | 0.13 |
|
| |||||
Notes:
P<0.05.
Abbreviations: CHcorr, corrected corneal hysteresis; CRFcorr, corrected corneal resistance factor; D, diopter; IOPCC, corneal compensated intraocular pressure; SE, standard error.