Literature DB >> 18521025

Ocular Response Analyzer in subjects with and without glaucoma.

Michael Sullivan-Mee1, Shavon C Billingsley, Amita D Patel, Kathy D Halverson, Brooks R Alldredge, Clifford Qualls.   

Abstract

PURPOSE: The Ocular Response Analyzer (ORA) is a newly introduced tonometer that uniquely measures and then integrates corneal biomechanical data into its intraocular pressure (IOP) estimates in an effort to improve accuracy of IOP assessment. This study was devised to investigate whether ORA-derived IOP and corneal biomechanical variables might be useful in discriminating between subjects with and without primary open-angle glaucoma (GLC).
METHODS: All patients seen in the Albuquerque VAMC eye clinic over a 10-week period who demonstrated acceptable ORA signal profiles were retrospectively identified. In subjects classified as normal (NML), ocular hypertension (OH), glaucoma suspect (GS), and GLC, the following variables were compared: age, ethnicity, Goldmann IOP, central corneal thickness (CCT), and ORA-derived data: Goldmann-correlated IOP (IOPg), corneal-compensated IOP (IOPcc), corneal resistance factor (CRF), corneal hysteresis (CH), and difference between IOPcc and IOPg (DIOP; IOPcc - IOPg).
RESULTS: Right eyes in 71 NML, 58 OH, 70 GS, and 99 GLC subjects were studied. Using analysis of variance, higher mean age, higher mean DIOP, and lower mean CH were found in the GLC group compared with OH, GS, and NML groups. In multivariate regression analyses, factors that independently discriminated between groups were: age, IOPcc, and DIOP (GLC vs. NML); age and IOPcc (GLC vs. GS); age and CRF (GLC vs. OH). When DIOP was left out of the models, CH replaced DIOP in the GLC vs. NML analysis with nearly equal statistical power.
CONCLUSIONS: Our results suggest that ORA-generated parameters may be useful for differentiating subjects with and without GLC. Furthermore, the discriminatory power of each ORA variable seems to depend on the diagnostic groups that are being compared. Finally, our findings also suggest that measured IOP may be significantly underestimated in glaucoma patients compared with non-glaucoma patients.

Entities:  

Mesh:

Year:  2008        PMID: 18521025     DOI: 10.1097/OPX.0b013e3181784673

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  40 in total

1.  Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer.

Authors:  Joo Young Shin; Jin Seok Choi; Joo Youn Oh; Mee Kum Kim; Jin Hak Lee; Won Ryang Wee
Journal:  Korean J Ophthalmol       Date:  2010-06-05

2.  Corneal biomechanical changes after trabeculectomy with mitomycin C in primary open-angle glaucoma and pseudoexfoliation glaucoma.

Authors:  Rana Sorkhabi; Farhad Najafzadeh; Ali Sadeghi; Mohamadhosein Ahoor; Ali Mahdavifard
Journal:  Int Ophthalmol       Date:  2019-05-27       Impact factor: 2.031

3.  Intravitreal silicone oil induced changes in corneal biomechanics.

Authors:  Mehmet Y Teke; Ufuk Elgin; Emine Sen; Pinar Ozdal; Faruk Ozturk
Journal:  Int Ophthalmol       Date:  2013-07-16       Impact factor: 2.031

4.  Intraocular pressure measured by dynamic contour tonometer and ocular response analyzer in normal tension glaucoma.

Authors:  Tetsuya Morita; Nobuyuki Shoji; Kazutaka Kamiya; Mana Hagishima; Fusako Fujimura; Kimiya Shimizu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-08-20       Impact factor: 3.117

5.  A Prospective Longitudinal Study to Investigate Corneal Hysteresis as a Risk Factor for Predicting Development of Glaucoma.

Authors:  Carolina N Susanna; Alberto Diniz-Filho; Fábio B Daga; Bianca N Susanna; Feilin Zhu; Nara G Ogata; Felipe A Medeiros
Journal:  Am J Ophthalmol       Date:  2018-01-02       Impact factor: 5.258

Review 6.  Tonometers-which one should I use?

Authors:  Kanza Aziz; David S Friedman
Journal:  Eye (Lond)       Date:  2018-02-19       Impact factor: 3.775

7.  Ocular response analyzer to assess corneal biomechanical properties in exfoliation syndrome and exfoliative glaucoma.

Authors:  Ali Bulent Cankaya; Alpaslan Anayol; Dilek Özcelik; Elif Demirdogen; Pelin Yilmazbas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-08-24       Impact factor: 3.117

8.  Corneal hysteresis and anterior segment optical coherence tomography anatomical parameters in primary angle closure suspects.

Authors:  Syed Amal Hussnain; Kyle D Kovacs; Joshua L Warren; Christopher C Teng
Journal:  Clin Exp Ophthalmol       Date:  2018-01-11       Impact factor: 4.207

9.  Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients.

Authors:  Emine Sen; Yasemin Tutuncu; Melike Balikoglu-Yilmaz; Ufuk Elgin; Dilek Berker; Faruk Ozturk; Serdar Guler
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-13       Impact factor: 3.117

10.  Comparison among Ocular Response Analyzer, Corvis ST and Goldmann applanation tonometry in healthy children.

Authors:  Ramin Salouti; Ali Agha Alishiri; Reza Gharebaghi; Mostafa Naderi; Khosrow Jadidi; Ahmad Shojaei-Baghini; Mohammadreza Talebnejad; Zahra Nasiri; Seyedmorteza Hosseini; Fatemeh Heidary
Journal:  Int J Ophthalmol       Date:  2018-08-18       Impact factor: 1.779

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.