Literature DB >> 28516049

Analysis of phase error effects in multishot diffusion-prepared turbo spin echo imaging.

Anh T Van1, Barbara Cervantes2, Hendrik Kooijman3, Dimitrios C Karampinos2.   

Abstract

BACKGROUND: To characterize the effect of phase errors on the magnitude and the phase of the diffusion-weighted (DW) signal acquired with diffusion-prepared turbo spin echo (dprep-TSE) sequences.
METHODS: Motion and eddy currents were identified as the main sources of phase errors. An analytical expression for the effect of phase errors on the acquired signal was derived and verified using Bloch simulations, phantom, and in vivo experiments.
RESULTS: Simulations and experiments showed that phase errors during the diffusion preparation cause both magnitude and phase modulation on the acquired data. When motion-induced phase error (MiPe) is accounted for (e.g., with motion-compensated diffusion encoding), the signal magnitude modulation due to the leftover eddy-current-induced phase error cannot be eliminated by the conventional phase cycling and sum-of-squares (SOS) method. By employing magnitude stabilizers, the phase-error-induced magnitude modulation, regardless of its cause, was removed but the phase modulation remained. The in vivo comparison between pulsed gradient and flow-compensated diffusion preparations showed that MiPe needed to be addressed in multi-shot dprep-TSE acquisitions employing magnitude stabilizers.
CONCLUSIONS: A comprehensive analysis of phase errors in dprep-TSE sequences showed that magnitude stabilizers are mandatory in removing the phase error induced magnitude modulation. Additionally, when multi-shot dprep-TSE is employed the inconsistent signal phase modulation across shots has to be resolved before shot-combination is performed.

Keywords:  Diffusion-prepared turbo spin echo (dprep-TSE); body diffusion; eddy currents; flow-compensation; motion-induced phase errors (MiPe)

Year:  2017        PMID: 28516049      PMCID: PMC5418150          DOI: 10.21037/qims.2017.04.01

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  33 in total

1.  Rapid isotropic diffusion mapping without susceptibility artifacts: whole brain studies using diffusion-weighted single-shot STEAM MR imaging.

Authors:  U G Nolte; J Finsterbusch; J Frahm
Journal:  Magn Reson Med       Date:  2000-11       Impact factor: 4.668

2.  Multishot diffusion-weighted FSE using PROPELLER MRI.

Authors:  James G Pipe; Victoria G Farthing; Kirsten P Forbes
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

3.  High-resolution diffusion-weighted 3D MRI, using diffusion-weighted driven-equilibrium (DW-DE) and multishot segmented 3D-SSFP without navigator echoes.

Authors:  Eun-Kee Jeong; Seong-Eun Kim; Dennis L Parker
Journal:  Magn Reson Med       Date:  2003-10       Impact factor: 4.668

4.  On the application of ultra-fast RARE experiments.

Authors:  D G Norris; P Börnert; T Reese; D Leibfritz
Journal:  Magn Reson Med       Date:  1992-09       Impact factor: 4.668

5.  Phase insensitive preparation of single-shot RARE: application to diffusion imaging in humans.

Authors:  D C Alsop
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

6.  Diffusion imaging with the MP-RAGE sequence.

Authors:  H Lee; R R Price
Journal:  J Magn Reson Imaging       Date:  1994 Nov-Dec       Impact factor: 4.813

7.  A new T2 preparation technique for ultrafast gradient-echo sequence.

Authors:  T Parrish; X Hu
Journal:  Magn Reson Med       Date:  1994-11       Impact factor: 4.668

8.  Diffusion-weighted MR microscopy with fast spin-echo.

Authors:  C F Beaulieu; X Zhou; G P Cofer; G A Johnson
Journal:  Magn Reson Med       Date:  1993-08       Impact factor: 4.668

9.  Isotropic diffusion-weighted and spiral-navigated interleaved EPI for routine imaging of acute stroke.

Authors:  K Butts; J Pauly; A de Crespigny; M Moseley
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

10.  Why fat is bright in RARE and fast spin-echo imaging.

Authors:  R M Henkelman; P A Hardy; J E Bishop; C S Poon; D B Plewes
Journal:  J Magn Reson Imaging       Date:  1992 Sep-Oct       Impact factor: 4.813

View more
  5 in total

1.  Three-dimensional simultaneous brain T1 , T2 , and ADC mapping with MR Multitasking.

Authors:  Sen Ma; Christopher T Nguyen; Fei Han; Nan Wang; Zixin Deng; Nader Binesh; Franklin G Moser; Anthony G Christodoulou; Debiao Li
Journal:  Magn Reson Med       Date:  2019-11-25       Impact factor: 4.668

2.  Volumetric and multispectral DWI near metallic implants using a non-linear phase Carr-Purcell-Meiboom-Gill diffusion preparation.

Authors:  Philip K Lee; Daehyun Yoon; Jesse K Sandberg; Shreyas S Vasanawala; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2022-01-11       Impact factor: 4.668

3.  Diffusion-prepared fast spin echo for artifact-free spinal cord imaging.

Authors:  Seung-Yi Lee; Briana P Meyer; Shekar N Kurpad; Matthew D Budde
Journal:  Magn Reson Med       Date:  2021-03-15       Impact factor: 3.737

4.  MR Fingerprinting with b-Tensor Encoding for Simultaneous Quantification of Relaxation and Diffusion in a Single Scan.

Authors:  Maryam Afzali; Lars Mueller; Ken Sakaie; Siyuan Hu; Yong Chen; Filip Szczepankiewicz; Mark A Griswold; Derek K Jones; Dan Ma
Journal:  Magn Reson Med       Date:  2022-06-17       Impact factor: 3.737

5.  Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo.

Authors:  Barbara Cervantes; Anh T Van; Dominik Weidlich; Hendrick Kooijman; Andreas Hock; Ernst J Rummeny; Alexandra Gersing; Jan S Kirschke; Dimitrios C Karampinos
Journal:  Magn Reson Med       Date:  2018-01-29       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.