Literature DB >> 27564132

Increased Speed and Image Quality for Pelvic Single-Shot Fast Spin-Echo Imaging with Variable Refocusing Flip Angles and Full-Fourier Acquisition.

Andreas M Loening1, Daniel V Litwiller1, Manojkumar Saranathan1, Shreyas S Vasanawala1.   

Abstract

Purpose To assess image quality and speed improvements for single-shot fast spin-echo (SSFSE) with variable refocusing flip angles and full-Fourier acquisition (vrfSSFSE) pelvic imaging via a prospective trial performed in the context of uterine leiomyoma evaluation. Materials and Methods Institutional review board approval and informed consent were obtained. vrfSSFSE and conventional SSFSE sagittal and coronal oblique acquisitions were performed in 54 consecutive female patients referred for 3-T magnetic resonance (MR) evaluation of known or suspected uterine leiomyomas. Two radiologists who were blinded to the image acquisition technique semiquantitatively scored images on a scale from -2 to 2 for noise, image contrast, sharpness, artifacts, and perceived ability to evaluate uterine, ovarian, and musculoskeletal structures. The null hypothesis of no significant difference between pulse sequences was assessed with a Wilcoxon signed rank test by using a Holm-Bonferroni correction for multiple comparisons. Results Because of reductions in specific absorption rate, vrfSSFSE imaging demonstrated significantly increased speed (more than twofold, P < .0001), with mean repetition times compared with conventional SSFSE imaging decreasing from 1358 to 613 msec for sagittal acquisitions and from 1494 to 621 msec for coronal oblique acquisitions. Almost all assessed image quality and perceived diagnostic capability parameters were significantly improved with vrfSSFSE imaging. These improvements included noise, sharpness, and ability to evaluate the junctional zone, myometrium, and musculoskeletal structures for both sagittal acquisitions (mean values of 0.56, 0.63, 0.42, 0.56, and 0.80, respectively; all P values < .0001) and coronal oblique acquisitions (mean values of 0.81, 1.09, 0.65, 0.93, and 1.12, respectively; all P values < .0001). For evaluation of artifacts, there was an insufficient number of cases with differences to allow statistical testing. Conclusion Compared with conventional SSFSE acquisition, vrfSSFSE acquisition increases 3-T imaging speed via reduced specific absorption rate and leads to significant improvements in perceived image quality and perceived diagnostic capability when evaluating pelvic structures. © RSNA, 2016 Online supplemental material is available for this article.

Entities:  

Mesh:

Year:  2016        PMID: 27564132      PMCID: PMC5283873          DOI: 10.1148/radiol.2016151574

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  15 in total

1.  Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS).

Authors:  Juergen Hennig; Matthias Weigel; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

2.  Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences.

Authors:  Matthias Philipp Lichy; Beate M Wietek; John P Mugler; Wilhelm Horger; Marion Irene Menzel; Aristotelis Anastasiadis; Katja Siegmann; Thomas Niemeyer; Arnulf Königsrainer; Berthold Kiefer; Fritz Schick; Claus D Claussen; Heinz-Peter Schlemmer
Journal:  Invest Radiol       Date:  2005-12       Impact factor: 6.016

3.  Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast.

Authors:  Reed F Busse; Hari Hariharan; Anthony Vu; Jean H Brittain
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

Review 4.  MRI of malignant neoplasms of the uterine corpus and cervix.

Authors:  Evis Sala; Suzanne Wakely; Emma Senior; David Lomas
Journal:  AJR Am J Roentgenol       Date:  2007-06       Impact factor: 3.959

Review 5.  Utility of the FIESTA pulse sequence in body oncologic imaging: review.

Authors:  Priya Bhosale; Jingfei Ma; Haesun Choi
Journal:  AJR Am J Roentgenol       Date:  2009-06       Impact factor: 3.959

6.  Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences.

Authors:  Nichanan Ruangwattanapaisarn; Andreas M Loening; Manojkumar Saranathan; Daniel V Litwiller; Shreyas S Vasanawala
Journal:  Pediatr Radiol       Date:  2014-11-30

Review 7.  MR imaging for preoperative evaluation of primary rectal cancer: practical considerations.

Authors:  Harmeet Kaur; Haesun Choi; Y Nancy You; Gaiane M Rauch; Corey T Jensen; Ping Hou; George J Chang; John M Skibber; Randy D Ernst
Journal:  Radiographics       Date:  2012 Mar-Apr       Impact factor: 5.333

8.  Increased speed and image quality in single-shot fast spin echo imaging via variable refocusing flip angles.

Authors:  Andreas M Loening; Manojkumar Saranathan; Nichanan Ruangwattanapaisarn; Daniel V Litwiller; Ann Shimakawa; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2015-06-19       Impact factor: 4.813

9.  Comparison of 3D and 2D FSE T2-weighted MRI in the diagnosis of deep pelvic endometriosis: preliminary results.

Authors:  M Bazot; A Stivalet; E Daraï; C Coudray; I Thomassin-Naggara; E Poncelet
Journal:  Clin Radiol       Date:  2012-07-24       Impact factor: 2.350

10.  Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo.

Authors:  Reed F Busse; Anja C S Brau; Anthony Vu; Charles R Michelich; Ersin Bayram; Richard Kijowski; Scott B Reeder; Howard A Rowley
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

View more
  4 in total

1.  Simultaneous PET/MRI in the Evaluation of Breast and Prostate Cancer Using Combined Na[18F] F and [18F]FDG: a Focus on Skeletal Lesions.

Authors:  Ida Sonni; Ryogo Minamimoto; Lucia Baratto; Sanjiv S Gambhir; Andreas M Loening; Shreyas S Vasanawala; Andrei Iagaru
Journal:  Mol Imaging Biol       Date:  2020-04       Impact factor: 3.488

2.  Variable Refocusing Flip Angle Single-Shot Imaging for Sedation-Free Fast Brain MRI.

Authors:  R Jabarkheel; E Tong; E H Lee; T M Cullen; U Yousaf; A M Loening; V Taviani; M Iv; G A Grant; S J Holdsworth; S S Vasanawala; K W Yeom
Journal:  AJNR Am J Neuroradiol       Date:  2020-06-25       Impact factor: 3.825

3.  Diagnostic Accuracy of 68Ga-PSMA-11 PET/MRI Compared with Multiparametric MRI in the Detection of Prostate Cancer.

Authors:  Robert M Hicks; Jeffry P Simko; Antonio C Westphalen; Hao G Nguyen; Kirsten L Greene; Li Zhang; Peter R Carroll; Thomas A Hope
Journal:  Radiology       Date:  2018-09-18       Impact factor: 11.105

4.  Data-driven self-calibration and reconstruction for non-cartesian wave-encoded single-shot fast spin echo using deep learning.

Authors:  Feiyu Chen; Joseph Y Cheng; Valentina Taviani; Vipul R Sheth; Ryan L Brunsing; John M Pauly; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2019-07-19       Impact factor: 4.813

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.