PURPOSE: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance.
METHODS: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ± 30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF).
RESULTS: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS were found to be different due to the difference in the tomosynthesis image reconstruction algorithms.
CONCLUSIONS: It is feasible to simultaneously generate x-ray differential phase contrast, phase contrast, and absorption contrast tomosynthesis images using a grating-based data acquisition setup. The method shows promise in improving the visibility of several low-density materials and therefore merits further investigation.

Entities:  

Mesh:

Year:  2014        PMID: 24387511      PMCID: PMC3874057          DOI: 10.1118/1.4835455

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

Review 1.  Digital x-ray tomosynthesis: current state of the art and clinical potential.

Authors:  James T Dobbins; Devon J Godfrey
Journal:  Phys Med Biol       Date:  2003-10-07       Impact factor: 3.609

2.  Cone-beam reprojection using projection-matrices.

Authors:  Ramesh R Galigekere; Karl Wiesent; David W Holdsworth
Journal:  IEEE Trans Med Imaging       Date:  2003-10       Impact factor: 10.048

3.  Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping.

Authors:  Nicholas Bevins; Joseph Zambelli; Ke Li; Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

4.  Radiation dose efficiency comparison between differential phase contrast CT and conventional absorption CT.

Authors:  Joseph Zambelli; Nicholas Bevins; Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

Review 5.  X-ray tomosynthesis: a review of its use for breast and chest imaging.

Authors:  Anders Tingberg
Journal:  Radiat Prot Dosimetry       Date:  2010-03-16       Impact factor: 0.972

6.  In-line phase shift tomosynthesis.

Authors:  Jeffrey C Hammonds; Ronald R Price; David R Pickens; Edwin F Donnelly
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

Review 7.  A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

8.  Fundamental relationship between the noise properties of grating-based differential phase contrast CT and absorption CT: theoretical framework using a cascaded system model and experimental validation.

Authors:  Ke Li; Nicholas Bevins; Joseph Zambelli; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

9.  Phase-contrast digital tomosynthesis.

Authors:  Jeffrey C Hammonds; Ronald R Price; Edwin F Donnelly; David R Pickens
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

10.  Spatial resolution characterization of differential phase contrast CT systems via modulation transfer function (MTF) measurements.

Authors:  Ke Li; Joseph Zambelli; Nicholas Bevins; Yongshuai Ge; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2013-05-17       Impact factor: 3.609

View more
  9 in total

1.  Improving radiation dose efficiency of X-ray differential phase contrast imaging using an energy-resolving grating interferometer and a novel rank constraint.

Authors:  Yongshuai Ge; Ran Zhang; Ke Li; Guang-Hong Chen
Journal:  Opt Express       Date:  2016-06-13       Impact factor: 3.894

Review 2.  Cardiac CT Imaging of Plaque Vulnerability: Hype or Hope?

Authors:  Martin J Willemink; Tim Leiner; Pál Maurovich-Horvat
Journal:  Curr Cardiol Rep       Date:  2016-04       Impact factor: 2.931

3.  Dual Energy Differential Phase Contrast CT (DE-DPC-CT) Imaging.

Authors:  Xu Ji; Ran Zhang; Ke Li; Guang-Hong Chen
Journal:  IEEE Trans Med Imaging       Date:  2020-10-28       Impact factor: 10.048

4.  Studies of signal estimation bias in grating-based x-ray multicontrast imaging.

Authors:  Xu Ji; Yongshuai Ge; Ran Zhang; Ke Li; Guang-Hong Chen
Journal:  Med Phys       Date:  2017-05-12       Impact factor: 4.071

5.  Fast acquisition with seamless stage translation (FASST) for a trimodal x-ray breast imaging system.

Authors:  Ran Zhang; Amy M Fowler; Lee G Wilke; Frederick Kelcz; John W Garrett; Guang-Hong Chen; Ke Li
Journal:  Med Phys       Date:  2020-06-23       Impact factor: 4.071

6.  Tomography of dark-field scatter including single-exposure Moiré fringe analysis with X-ray biprism interferometry-A simulation study.

Authors:  Weijie Tao; Yongjin Sung; Sally Ji Who Kim; Qiu Huang; Grant T Gullberg; Youngho Seo; Michael Fuller
Journal:  Med Phys       Date:  2021-08-18       Impact factor: 4.506

7.  X-ray interferometry without analyzer for breast CT application: a simulation study.

Authors:  Jingzhu Xu; Kyungmin Ham; Joyoni Dey
Journal:  J Med Imaging (Bellingham)       Date:  2020-03-26

8.  Implementation of a Talbot-Lau interferometer in a clinical-like c-arm setup: A feasibility study.

Authors:  Florian Horn; Martino Leghissa; Sebastian Kaeppler; Georg Pelzer; Jens Rieger; Maria Seifert; Johannes Wandner; Thomas Weber; Thilo Michel; Christian Riess; Gisela Anton
Journal:  Sci Rep       Date:  2018-02-02       Impact factor: 4.379

9.  Retrieval of 3D information in X-ray dark-field imaging with a large field of view.

Authors:  Jana Andrejewski; Fabio De Marco; Konstantin Willer; Wolfgang Noichl; Theresa Urban; Manuela Frank; Alex Gustschin; Pascal Meyer; Thomas Koehler; Franz Pfeiffer; Julia Herzen
Journal:  Sci Rep       Date:  2021-12-06       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.