Denoising of 4D Cardiac Micro-CT Data Using Median-Centric Bilateral Filtration.

D Clark1, G A Johnson1, C T Badea1.   

Abstract

Bilateral filtration has proven an effective tool for denoising CT data. The classic filter utilizes Gaussian domain and range weighting functions in 2D. More recently, other distributions have yielded more accurate results in specific applications, and the bilateral filtration framework has been extended to higher dimensions. In this study, brute-force optimization is employed to evaluate the use of several alternative distributions for both domain and range weighting: Andrew's Sine Wave, El Fallah Ford, Gaussian, Flat, Lorentzian, Huber's Minimax, Tukey's Bi-weight, and Cosine. Two variations on the classic bilateral filter which use median filtration to reduce bias in range weights are also investigated: median-centric and hybrid bilateral filtration. Using the 4D MOBY mouse phantom reconstructed with noise (stdev. ~ 65 HU), hybrid bilateral filtration, a combination of the classic and median-centric filters, with Flat domain and range weighting is shown to provide optimal denoising results (PSNRs: 31.69, classic; 31.58 median-centric; 32.25, hybrid). To validate these phantom studies, the optimal filters are also applied to in vivo, 4D cardiac micro-CT data acquired in the mouse. In a constant region of the left ventricle, hybrid bilateral filtration with Flat domain and range weighting is shown to provide optimal smoothing (stdev: original, 72.2 HU; classic, 20.3 HU; median-centric, 24.1 HU; hybrid, 15.9 HU). While the optimal results were obtained using 4D filtration, the 3D hybrid filter is ultimately recommended for denoising 4D cardiac micro-CT data because it is more computationally tractable and less prone to artifacts (MOBY PSNR: 32.05; left ventricle stdev: 20.5 HU).

Entities:  

Keywords:  4D; bilateral filtration; cardiac imaging; denoising; in vivo; micro-CT; small animal

Year:  2012        PMID: 24386540      PMCID: PMC3877307          DOI: 10.1117/12.911478

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  8 in total

1.  A dual micro-CT system for small animal imaging.

Authors:  C T Badea; S Johnston; B Johnson; M Lin; L W Hedlund; G Allan Johnson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008-04-18

2.  Kernel regression for image processing and reconstruction.

Authors:  Hiroyuki Takeda; Sina Farsiu; Peyman Milanfar
Journal:  IEEE Trans Image Process       Date:  2007-02       Impact factor: 10.856

3.  Micro-CT with respiratory and cardiac gating.

Authors:  C Badea; L W Hedlund; G A Johnson
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

4.  Optimal short scan convolution reconstruction for fanbeam CT.

Authors:  D L Parker
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

5.  A liposomal nanoscale contrast agent for preclinical CT in mice.

Authors:  Srinivasan Mukundan; Ketan B Ghaghada; Cristian T Badea; Chen-Yu Kao; Laurence W Hedlund; James M Provenzale; G Allan Johnson; Emmanuel Chen; Ravi V Bellamkonda; Ananth Annapragada
Journal:  AJR Am J Roentgenol       Date:  2006-02       Impact factor: 3.959

6.  Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals.

Authors:  Stefan Sawall; Frank Bergner; Robert Lapp; Markus Mronz; Marek Karolczak; Andreas Hess; Marc Kachelriess
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  Rapid production of specialized animal handling devices using computer-aided design and solid freeform fabrication.

Authors:  Gabriel P Howles; John C Nouls; Yi Qi; G Allan Johnson
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

8.  Development of a 4-D digital mouse phantom for molecular imaging research.

Authors:  William P Segars; Benjamin M W Tsui; Eric C Frey; G Allan Johnson; Stuart S Berr
Journal:  Mol Imaging Biol       Date:  2004 May-Jun       Impact factor: 3.488

  8 in total
  9 in total

1.  Registration-based segmentation of murine 4D cardiac micro-CT data using symmetric normalization.

Authors:  Darin Clark; Alexandra Badea; Yilin Liu; G Allan Johnson; Cristian T Badea
Journal:  Phys Med Biol       Date:  2012-09-13       Impact factor: 3.609

2.  Spectral diffusion: an algorithm for robust material decomposition of spectral CT data.

Authors:  Darin P Clark; Cristian T Badea
Journal:  Phys Med Biol       Date:  2014-10-08       Impact factor: 3.609

3.  In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT.

Authors:  Darin P Clark; Ketan Ghaghada; Everett J Moding; David G Kirsch; Cristian T Badea
Journal:  Phys Med Biol       Date:  2013-02-19       Impact factor: 3.609

4.  Dual-energy computed tomography imaging of atherosclerotic plaques in a mouse model using a liposomal-iodine nanoparticle contrast agent.

Authors:  Rohan Bhavane; Cristian Badea; Ketan B Ghaghada; Darin Clark; Deborah Vela; Anoosha Moturu; Akshaya Annapragada; G Allan Johnson; James T Willerson; Ananth Annapragada
Journal:  Circ Cardiovasc Imaging       Date:  2013-01-24       Impact factor: 7.792

5.  Dual-energy micro-computed tomography imaging of radiation-induced vascular changes in primary mouse sarcomas.

Authors:  Everett J Moding; Darin P Clark; Yi Qi; Yifan Li; Yan Ma; Ketan Ghaghada; G Allan Johnson; David G Kirsch; Cristian T Badea
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-11-01       Impact factor: 7.038

6.  A comparative analysis of EGFR-targeting antibodies for gold nanoparticle CT imaging of lung cancer.

Authors:  Jeffrey R Ashton; Elizabeth B Gottlin; Edward F Patz; Jennifer L West; Cristian T Badea
Journal:  PLoS One       Date:  2018-11-08       Impact factor: 3.752

7.  Dual-energy micro-CT functional imaging of primary lung cancer in mice using gold and iodine nanoparticle contrast agents: a validation study.

Authors:  Jeffrey R Ashton; Darin P Clark; Everett J Moding; Ketan Ghaghada; David G Kirsch; Jennifer L West; Cristian T Badea
Journal:  PLoS One       Date:  2014-02-10       Impact factor: 3.240

8.  Dual-Energy CT Imaging of Tumor Liposome Delivery After Gold Nanoparticle-Augmented Radiation Therapy.

Authors:  Jeffrey R Ashton; Katherine D Castle; Yi Qi; David G Kirsch; Jennifer L West; Cristian T Badea
Journal:  Theranostics       Date:  2018-02-12       Impact factor: 11.600

9.  The impact of respiratory gating on improving volume measurement of murine lung tumors in micro-CT imaging.

Authors:  S J Blocker; M D Holbrook; Y M Mowery; D C Sullivan; C T Badea
Journal:  PLoS One       Date:  2020-02-25       Impact factor: 3.240