Literature DB >> 12363214

Comparison of five methods for fit-testing N95 filtering-facepiece respirators.

Christopher C Coffey1, Robert B Lawrence, Ziqing Zhuang, Donald L Campbell, Paul A Jensen, Warren R Myers.   

Abstract

Five fit-testing methods (Bitrex, ambient aerosol condensation nuclei counter using the TSI PortaCount Plus, saccharin, modified ambient aerosol condensation nuclei counter using the TSI PortaCount Plus with the N95-Companion, and generated aerosol using corn oil) were evaluated for their ability to identify poorly fitting N95 filtering-facepiece respirators. Eighteen models of NIOSH-certified, N95 filtering-facepiece respirators were tested by a panel of 25 subjects using each fit-testing method. The penetration of the corn oil and the ambient aerosols through the filter media of each respirator was measured in order to adjust the corresponding generated and ambient aerosol overall fit factors, reflecting only face-seal leakage. Fit-testing results were compared to 5th percentiles of simulated workplace protection factors. Beta errors (the chance of passing a fit-test in error) ranged from 3 percent to 11 percent. Alpha errors (the chance of failing a fit-test in error) ranged from 51 percent to 84 percent. The ambient aerosol using the TSI PortaCount Plus and the generated aerosol methods identified poorly fitting respirators better than the saccharin, the Companion, and Bitrex methods. These errors rates should be considered when selecting a fit-testing method for fitting N95 filtering-facepieces. When both types of errors were combined as an assignment error, the ambient aerosol method using the TSI PortaCount Plus had the lowest percentage of wearers being assigned a poor-fitting respirator.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12363214     DOI: 10.1080/10473220290107002

Source DB:  PubMed          Journal:  Appl Occup Environ Hyg        ISSN: 1047-322X


  13 in total

Review 1.  Transmission and Institutional Infection Control of Tuberculosis.

Authors:  Edward A Nardell
Journal:  Cold Spring Harb Perspect Med       Date:  2015-08-20       Impact factor: 6.915

2.  2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care Settings.

Authors:  Jane D Siegel; Emily Rhinehart; Marguerite Jackson; Linda Chiarello
Journal:  Am J Infect Control       Date:  2007-12       Impact factor: 2.918

3.  Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile.

Authors:  Michael Bergman; Ziqing Zhuang; Elizabeth Brochu; Andrew Palmiero
Journal:  J Int Soc Respir Prot       Date:  2015

4.  Qualitative fitting characteristics of filtering face-piece respirators on Iranian people.

Authors:  Anahita Fakherpour; Mehdi Jahangiri; Mozhgan Seif
Journal:  J Environ Health Sci Eng       Date:  2020-05-26

5.  Inward Leakage Variability between Respirator Fit Test Panels - Part I. Deterministic Approach.

Authors:  Ziqing Zhuang; Yuewei Liu; Christopher C Coffey; Colleen Miller; Jonathan Szalajda
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

6.  Development of an advanced respirator fit-test headform.

Authors:  Michael S Bergman; Ziqing Zhuang; David Hanson; Brian K Heimbuch; Michael J McDonald; Andrew J Palmiero; Ronald E Shaffer; Delbert Harnish; Michael Husband; Joseph D Wander
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

7.  Characterization of small-to-medium head-and-face dimensions for developing respirator fit test panels and evaluating fit of filtering facepiece respirators with different faceseal design.

Authors:  Yi-Chun Lin; Chen-Peng Chen
Journal:  PLoS One       Date:  2017-11-27       Impact factor: 3.240

8.  Tuberculosis in healthcare workers - a narrative review from a German perspective.

Authors:  Albert Nienhaus; Anja Schablon; Alexandra M Preisser; Felix C Ringshausen; Roland Diel
Journal:  J Occup Med Toxicol       Date:  2014-03-14       Impact factor: 2.646

9.  The education and practice program for medical students with quantitative and qualitative fit test for respiratory protective equipment.

Authors:  Jun-Pyo Myong; JunSu Byun; YounMo Cho; Hye-Kyung Seo; Jung-Eun Baek; Jung-Wan Koo; Hyunwook Kim
Journal:  Ind Health       Date:  2015-11-03       Impact factor: 2.179

10.  Temporal changes in filtering-facepiece respirator fit.

Authors:  Ziqing Zhuang; Michael Bergman; Elizabeth Brochu; Andrew Palmiero; George Niezgoda; Xinjian He; Raymond Roberge; Ronald Shaffer
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.