Literature DB >> 17654225

Workplace protection factors for an N95 filtering facepiece respirator.

Larry L Janssen1, Thomas J Nelson, Karen T Cuta.   

Abstract

This study evaluated the workplace performance of an N95 filtering facepiece, air-purifying respirator in a steel foundry. Air samples were collected inside and outside respirators worn by workers who were properly trained and qualitatively fit tested. For most workers, three or four pairs of air samples were collected on each of 2 days. The 49 valid sample sets were analyzed for iron, silicon, and zirconium. Only iron was present in sufficient concentrations to perform workplace protection factor (WPF) calculations. Individual WPF measurements ranged from 5 to 753. The geometric mean of the distribution was 119 with a lower 5th percentile value of 19. Time-weighted average WPFs (WPF(TWA)) were also calculated for each day for each worker as an estimate of the protection an individual might receive with daily respirator use. The WPF(TWA) values ranged from 15 for the worker with the single WPF value of 5, to a high of 684. The distribution of WPF(TWA) had a geometric mean of 120 and a lower 5th percentile of 22. Both data treatments indicate this respirator's performance was consistent with the assigned protection factor of 10 typically used for half facepiece respirators. The respirator provided adequate protection as used in this study. All contaminant concentrations inside the respirator were well below the relevant occupational exposure limits. Data collected also illustrate the dynamic nature of faceseal leakage in the workplace.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17654225     DOI: 10.1080/15459620701517764

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  18 in total

1.  Exposure to respirable dust and manganese and prevalence of airways symptoms, among Swedish mild steel welders in the manufacturing industry.

Authors:  Maria Hedmer; Jan-Eric Karlsson; Ulla Andersson; Helene Jacobsson; Jörn Nielsen; Håkan Tinnerberg
Journal:  Int Arch Occup Environ Health       Date:  2013-08-25       Impact factor: 3.015

2.  Assessing the efficacy of tabs on filtering facepiece respirator straps to increase proper doffing techniques while reducing contact transmission of pathogens.

Authors:  Amanda L Strauch; Tyler M Brady; George Niezgoda; Claudia M Almaguer; Ronald E Shaffer; Edward M Fisher
Journal:  J Occup Environ Hyg       Date:  2016-10-02       Impact factor: 2.155

3.  Protection factor for N95 filtering facepiece respirators exposed to laboratory aerosols containing different concentrations of nanoparticles.

Authors:  Samy Rengasamy; Gary Walbert; William Newcomb; Christopher Coffey; James Terrence Wassell; Jonathan Szalajda
Journal:  Ann Occup Hyg       Date:  2014-11-25

Review 4.  Selecting models for a respiratory protection program: what can we learn from the scientific literature?

Authors:  Ronald E Shaffer; Larry L Janssen
Journal:  Am J Infect Control       Date:  2014-12-10       Impact factor: 2.918

5.  Are quantitative fit factors predictive of respirator fit during simulated healthcare activities?

Authors:  Margaret Sietsema; Lisa M Brosseau
Journal:  J Occup Environ Hyg       Date:  2018-12       Impact factor: 2.155

6.  Criteria for the collection of useful respirator performance data in the workplace.

Authors:  Larry Janssen; Ziqing Zhuang; Ronald Shaffer
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

7.  Development of an advanced respirator fit-test headform.

Authors:  Michael S Bergman; Ziqing Zhuang; David Hanson; Brian K Heimbuch; Michael J McDonald; Andrew J Palmiero; Ronald E Shaffer; Delbert Harnish; Michael Husband; Joseph D Wander
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

8.  Validation and application of models to predict facemask influenza contamination in healthcare settings.

Authors:  Edward M Fisher; John D Noti; William G Lindsley; Francoise M Blachere; Ronald E Shaffer
Journal:  Risk Anal       Date:  2014-03-04       Impact factor: 4.000

9.  Challenge of N95 filtering facepiece respirators with viable H1N1 influenza aerosols.

Authors:  Delbert A Harnish; Brian K Heimbuch; Michael Husband; April E Lumley; Kimberly Kinney; Ronald E Shaffer; Joseph D Wander
Journal:  Infect Control Hosp Epidemiol       Date:  2013-05       Impact factor: 3.254

10.  A Cross-Sectional Study of the Cardiovascular Effects of Welding Fumes.

Authors:  Huiqi Li; Maria Hedmer; Monica Kåredal; Jonas Björk; Leo Stockfelt; Håkan Tinnerberg; Maria Albin; Karin Broberg
Journal:  PLoS One       Date:  2015-07-06       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.