Literature DB >> 24368115

Repeatability of aberrometric measurements in normal and keratoconus eyes using a new Scheimpflug-Placido topographer.

Hasan Ali Bayhan1, Seray Aslan Bayhan2, Ersin Muhafız2, Izzet Can2.   

Abstract

PURPOSE: To evaluate the repeatability of the anterior and posterior corneal wavefront aberrations using the Sirius Scheimpflug-Placido topographer in normal eyes and keratoconus eyes.
SETTING: Bozok University Faculty of Medicine, Yozgat, Turkey.
DESIGN: Evaluation of diagnostic test.
METHODS: In eyes of healthy subjects and eyes of keratoconus patients, 3 repeated measurements were obtained using the Scheimpflug-Placido topographer. Repeatability of the corneal aberrometric data using a 7th-order Zernike expansion (6.0 mm pupil) and central corneal power (3.0 mm zone) in the anterior and posterior corneal surfaces were analyzed. The within-subject standard deviation (Sw) and the intraclass correlation coefficient (ICC) were calculated.
RESULTS: For all modal pairs, the Sw was 0.08 μm or less for anterior and posterior corneal aberrations in both groups. The ICC of the anterior corneal surface ranged from 0.607 (pentafoil) to 0.988 (primary coma) in keratoconus eyes (n = 41) and from 0.568 (quadrifoil) to 0.856 (primary coma) in normal eyes (n = 30). The ICCs for posterior corneal surface aberrometry were 0.656 to 0.873 and 0.592 to 0.824, respectively. For anterior and posterior corneal curvatures, the Sw was 0.12 or lower and the ICC values were more than 0.93 in all cases except the posterior corneal surface reading at the 3.0 mm corneal area in keratoconus eyes (ICC 0.875).
CONCLUSIONS: The intraexaminer repeatability of most anterior corneal aberrations with the Scheimpflug-Placido system was moderate to high in normal eyes and keratoconus eyes. The system showed moderate repeatability for the posterior corneal surface. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 24368115     DOI: 10.1016/j.jcrs.2013.07.046

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  12 in total

1.  Reliability of Tonolab measurements in rats.

Authors:  Li-Fang Liu; Chu-Kai Huang; Ming-Zhi Zhang
Journal:  Int J Ophthalmol       Date:  2014-12-18       Impact factor: 1.779

2.  Validation of corneal topographic and aberrometric measurements obtained by color light-emitting diode reflection topography in healthy eyes.

Authors:  David P Piñero; Ainhoa Molina-Martín; Vicent J Camps; Dolores de Fez; María Teresa Caballero
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-09-03       Impact factor: 3.117

3.  Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability.

Authors:  David P Piñero; Alberto López-Navarro; Inmaculada Cabezos; Dolores de Fez; María T Caballero; Vicent J Camps
Journal:  J Ophthalmol       Date:  2017-01-04       Impact factor: 1.909

4.  Evaluation of the anterior segment parameters after Nd: YAG laser Capsulotomy: Effect the design of intraocular lens Haptic.

Authors:  Berkay Akmaz; Fahrettin Akay
Journal:  Pak J Med Sci       Date:  2018 Mar-Apr       Impact factor: 1.088

5.  Intrasession repeatability of refractive and ocular aberrometric measurements obtained using a multidiagnostic device in healthy eyes.

Authors:  David P Piñero; Alberto López-Navarro; Inmaculada Cabezos; Dolores de Fez; María T Caballero; Vicent J Camps
Journal:  Clin Optom (Auckl)       Date:  2017-05-04

6.  Evaluation of Corneal Higher-Order Aberrations by Scheimpflug-Placido Topography in Patients with Different Refractive Errors: A Retrospective Observational Study.

Authors:  Mohamed Anbar; Engy Mohamed Mostafa; Ashraf Mostafa Elhawary; Islam Awny; Mahmoud Mohamed Farouk; Amr Mounir
Journal:  J Ophthalmol       Date:  2019-06-02       Impact factor: 1.909

7.  Comparison of higher order wavefront aberrations with four aberrometers.

Authors:  William H Cook; James McKelvie; Henry B Wallace; Stuti L Misra
Journal:  Indian J Ophthalmol       Date:  2019-07       Impact factor: 1.848

Review 8.  Galilei Corneal Tomography for Screening of Refractive Surgery Candidates: A Review of the Literature, Part II.

Authors:  Majid Moshirfar; Mahsaw N Motlagh; Michael S Murri; Hamed Momeni-Moghaddam; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019

9.  Repeatability and reproducibility of corneal higher-order aberrations measurements after small incision lenticule extraction using the Scheimpflug-Placido topographer.

Authors:  Rui Ning; Rongrong Gao; David P Piñero; Jun Zhang; Qingyi Gao; Yili Jin; Yiran Wang; Chenxiao Wang; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2022-01-04

10.  Comparison of the Optical Quality between Small Incision Lenticule Extraction and Femtosecond Laser LASIK.

Authors:  Ying Jin; Yan Wang; Lulu Xu; Tong Zuo; Hua Li; Rui Dou; Jiamei Zhang
Journal:  J Ophthalmol       Date:  2016-11-10       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.