Wear resistance of four types of vacuum-formed retainer materials: a laboratory study.

Taiyub A Raja1, Simon J Littlewood, Theresa Munyombwe, Nigel L Bubb.   

Abstract

OBJECTIVE: To investigate the resistance to wear of four different vacuum-formed retainer (VFR) materials: Essix C+, Essix ACE, Duran, and Tru-Tain. Essix C+ is a polypropylene polymer; the other materials are polyethylene co-polymers.
MATERIALS AND METHODS: The study was undertaken at the Leeds Dental Institute, Leeds, UK, with 26 samples in each group. The specimens were vacuum-formed according to the manufacturers' guidelines, and a custom-made wear-simulation machine was used to conduct the test. Each specimen was subjected to 1000 cycles of the wear simulation, with steatite balls as the antagonist material. The resistance to wear of the VFR materials was evaluated by measuring the maximum wear depth using noncontact, three-dimensional surface profilometry. The wear depth was given in micrometers.
RESULTS: The median wear depth was 63.20 µm for the Essix C+ group, 7.88 µm for the Essix ACE group, 9.75 µm for the Duran group, and 12.08 µm for the Tru-Tain group. The Kruskal-Wallis test to compare the four VFR materials detected a statistically significant difference between the groups (P < .001). Comparisons of the groups using the Mann-Whitney U-test demonstrated that the Essix C+ group had significantly greater wear than the other three groups (P < .001). There was no statistically significant difference in median wear depth between the two groups with the least amount of wear-the Essix ACE and Duran groups.
CONCLUSIONS: Under the standardized conditions of this laboratory study, the three polyethylene co-polymer materials-Essix ACE, Duran, and Tru-Tain-exhibited significantly less wear than the polypropylene material, Essix C+.

Entities:  

Keywords:  VFR; Vacuum-formed retainer; Wear resistance; Wear test

Mesh:

Substances:

Year:  2013        PMID: 24364752      PMCID: PMC8650450          DOI: 10.2319/061313-448.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  19 in total

1.  Serial extraction of first premolars--postretention evaluation of stability and relapse.

Authors:  R M Little; R A Riedel; E D Engst
Journal:  Angle Orthod       Date:  1990       Impact factor: 2.079

2.  Mandibular second premolar extraction--postretention evaluation of stability and relapse.

Authors:  D C McReynolds; R M Little
Journal:  Angle Orthod       Date:  1991       Impact factor: 2.079

3.  The effectiveness of Hawley and vacuum-formed retainers: a single-center randomized controlled trial.

Authors:  Heidi Rowland; Lisa Hichens; Alison Williams; Darren Hills; Norman Killingback; Paul Ewings; Steven Clark; Anthony J Ireland; Jonathan R Sandy
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-12       Impact factor: 2.650

Review 4.  Toward a perspective on orthodontic retention?

Authors:  C Melrose; D T Millett
Journal:  Am J Orthod Dentofacial Orthop       Date:  1998-05       Impact factor: 2.650

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Essix retainers: fabrication and supervision for permanent retention.

Authors:  J J Sheridan; W LeDoux; R McMinn
Journal:  J Clin Orthod       Date:  1993-01

7.  Stability and relapse of mandibular anterior alignment-first premolar extraction cases treated by traditional edgewise orthodontics.

Authors:  R M Little; T R Wallen; R A Riedel
Journal:  Am J Orthod       Date:  1981-10

8.  Mandibular incisor extraction--postretention evaluation of stability and relapse.

Authors:  R A Riedel; R M Little; T D Bui
Journal:  Angle Orthod       Date:  1992       Impact factor: 2.079

9.  Cost-effectiveness and patient satisfaction: Hawley and vacuum-formed retainers.

Authors:  Lisa Hichens; Heidi Rowland; Alison Williams; Sandra Hollinghurst; Paul Ewings; Steven Clark; Anthony Ireland; Jonathan Sandy
Journal:  Eur J Orthod       Date:  2007-08       Impact factor: 3.075

10.  In vitro wear of various orthotic device materials.

Authors:  Jeffery Casey; William J Dunn; Edward Wright
Journal:  J Prosthet Dent       Date:  2003-11       Impact factor: 3.426

View more
  7 in total

1.  Long-term effects of different cleaning methods on copolyester retainer properties.

Authors:  Emily Wible; Manika Agarwal; Sibel Altun; Tyler Ramir; Grace Viana; Carla Evans; Henry Lukic; Spiro Megremis; Phimon Atsawasuwan
Journal:  Angle Orthod       Date:  2018-08-03       Impact factor: 2.079

2.  Long-term effects of various cleaning methods on polypropylene/ethylene copolymer retainer material.

Authors:  Emily Wible; Manika Agarwal; Sibel Altun; Tyler Ramir; Grace Viana; Carla Evans; Henry Lukic; Spiro Megremis; Phimon Atsawasuwan
Journal:  Angle Orthod       Date:  2019-01-02       Impact factor: 2.079

3.  Comparison of Wear Resistance of Hawley and Vacuum Formed Retainers: An in-vitro Study.

Authors:  Moshkelgosha V; Shomali M; Momeni M
Journal:  J Dent Biomater       Date:  2016-06

4.  Evaluation of biofilm formation on different clear orthodontic retainer materials.

Authors:  Suhad M Hamdoon; Saeed AlSamak; Mahmood Kh Ahmed; Saad Gasgoos
Journal:  J Orthod Sci       Date:  2022-08-24

5.  Evaluation of the Efficacy of Different Cleaning Methods for Orthodontic Thermoplastic Retainers in terms of Bacterial Colonization.

Authors:  Filiz Aydoğan Akgün; Neslihan Ebru Şenışık; Emel Sesli Çetin
Journal:  Turk J Orthod       Date:  2019-12-01

6.  A new type of clear orthodontic retainer incorporating multi-layer hybrid materials.

Authors:  Hyo-Won Ahn; Kyung A Kim; Seong-Hun Kim
Journal:  Korean J Orthod       Date:  2015-09-23       Impact factor: 1.372

7.  Orthodontic Aligner Incorporating Eucommia ulmoides Exerts Low Continuous Force: In Vitro Study.

Authors:  Sayuri Inoue; Satoshi Yamaguchi; Hiroshi Uyama; Takashi Yamashiro; Satoshi Imazato
Journal:  Materials (Basel)       Date:  2020-09-14       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.