STATEMENT OF PROBLEM: Orthotic devices are advocated to decrease occlusal attrition caused by bruxism but tend to wear with time.
PURPOSE: This study investigated the wear rate of various materials used to fabricate orthotic devices.
MATERIAL AND METHODS: Five experimental groups (n=8) were studied: Splint Biocryl autopolymerized (SBA), Splint Biocryl autopolymerized plus additional heat and pressure (SBHP), Forestacryl autopolymerized (FA), Forestacryl autopolymerized plus additional heat and pressure (FHP), and Quick Splint 15-minute (QS), light-polymerized composite. Specimens were mounted to the base of a universal testing machine. A wear device using steatite balls and a load of 9.1 kg was positioned against the specimens, submerged in a 37 degrees C water bath and subjected to 2500 reciprocal cycles. Wear, in micrometers, was calculated as the maximum peak to valley measurement (Ry) using profilometry. Data were subjected to analysis of variance (ANOVA) and Tukey's HSD (alpha=.05).
RESULTS: Mean acrylic wear in micrometers was as follows: FA 6.8 +/-3.0; FHP 7.1 +/- 1.8; SBA 20.4 +/- 5.6; SBHP 23.7 +/- 7.8; and QS 23.8 +/- 6.9. One-way ANOVA detected significant differences between groups (P<.001); the Tukey honestly significant difference test determined that FA and FHP specimens were significantly more resistant to wear than all other specimens (P=.007).
CONCLUSION: Differences in in vitro wear resistance among various orthotic device materials exist. The in vitro wear resistance among other autopolymerizing materials appears to be related to proprietary differences.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14586313     DOI: 10.1016/s0022-3913(03)00545-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers.

Authors:  Merve Benli; Beril Eker Gümüş; Yusuf Kahraman; Bilge Gökçen-Rohlig; Gülümser Evlioğlu; Olivier Huck; Mutlu Özcan
Journal:  Odontology       Date:  2019-10-14       Impact factor: 2.634

2.  Comparison of Wear Resistance of Hawley and Vacuum Formed Retainers: An in-vitro Study.

Authors:  Moshkelgosha V; Shomali M; Momeni M
Journal:  J Dent Biomater       Date:  2016-06

3.  Two-body wear of occlusal splint materials against different antagonists.

Authors:  Kubra Yildiz Domanic; Yilmaz Umut Aslan; Yasemin Ozkan
Journal:  BMC Oral Health       Date:  2020-06-22       Impact factor: 2.757

4.  Wear resistance of four types of vacuum-formed retainer materials: a laboratory study.

Authors:  Taiyub A Raja; Simon J Littlewood; Theresa Munyombwe; Nigel L Bubb
Journal:  Angle Orthod       Date:  2013-12-23       Impact factor: 2.079

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.