Literature DB >> 17354829

3D/2D model-to-image registration applied to TIPS surgery.

Julien Jomier1, Elizabeth Bullitt, Mark Van Horn, Chetna Pathak, Stephen R Aylward.   

Abstract

We have developed a novel model-to-image registration technique which aligns a 3-dimensional model of vasculature with two semiorthogonal fluoroscopic projections. Our vascular registration method is used to intra-operatively initialize the alignment of a catheter and a preoperative vascular model in the context of image-guided TIPS (Transjugular, Intrahepatic, Portosystemic Shunt formation) surgery. Registration optimization is driven by the intensity information from the projection pairs at sample points along the centerlines of the model. Our algorithm shows speed, accuracy and consistency given clinical data.

Mesh:

Year:  2006        PMID: 17354829      PMCID: PMC2430607          DOI: 10.1007/11866763_81

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  3 in total

1.  Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction.

Authors:  Stephen R Aylward; Elizabeth Bullitt
Journal:  IEEE Trans Med Imaging       Date:  2002-02       Impact factor: 10.048

2.  A comparison of a similarity-based and a feature-based 2-D-3-D registration method for neurointerventional use.

Authors:  Robert A McLaughlin; John Hipwell; David J Hawkes; J Alison Noble; James V Byrne; Tim C Cox
Journal:  IEEE Trans Med Imaging       Date:  2005-08       Impact factor: 10.048

3.  A comparison of similarity measures for use in 2-D-3-D medical image registration.

Authors:  G P Penney; J Weese; J A Little; P Desmedt; D L Hill; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1998-08       Impact factor: 10.048

  3 in total
  7 in total

1.  [Image guiding techniques and navigation for TACE, SIRT and TIPS].

Authors:  R Adamus; M Pfister; M Uder; R W Loose
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

2.  3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy.

Authors:  A Uneri; Y Otake; A S Wang; G Kleinszig; S Vogt; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

3.  Intraoperative image-based multiview 2D/3D registration for image-guided orthopaedic surgery: incorporation of fiducial-based C-arm tracking and GPU-acceleration.

Authors:  Yoshito Otake; Mehran Armand; Robert S Armiger; Michael D Kutzer; Ehsan Basafa; Peter Kazanzides; Russell H Taylor
Journal:  IEEE Trans Med Imaging       Date:  2011-11-18       Impact factor: 10.048

4.  3D-2D registration in endovascular image-guided surgery: evaluation of state-of-the-art methods on cerebral angiograms.

Authors:  Uroš Mitrović; Boštjan Likar; Franjo Pernuš; Žiga Špiclin
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-10-24       Impact factor: 2.924

5.  Continuous roadmapping in liver TACE procedures using 2D-3D catheter-based registration.

Authors:  Pierre Ambrosini; Daniel Ruijters; Wiro J Niessen; Adriaan Moelker; Theo van Walsum
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-05-20       Impact factor: 2.924

6.  Multimodal image registration of the scoliotic torso for surgical planning.

Authors:  Rola Harmouche; Farida Cheriet; Hubert Labelle; Jean Dansereau
Journal:  BMC Med Imaging       Date:  2013-01-04       Impact factor: 1.930

7.  Evaluation and Verification of Fast Computational Simulations of Stent-Graft Deployment in Endovascular Aneurysmal Repair.

Authors:  Aymeric Pionteck; Baptiste Pierrat; Sébastien Gorges; Jean-Noël Albertini; Stéphane Avril
Journal:  Front Med Technol       Date:  2021-07-20
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.