Literature DB >> 19436098

Design of a novel slit-slat collimator system for SPECT imaging of the human brain.

S T Mahmood1, K Erlandsson, I Cullum, B F Hutton.   

Abstract

We present three novel multi-slit-slat (MSS) system designs which allow for the acquisition of data with variable multiplexing in order to optimize the use of a high intrinsic resolution detector for clinical brain SPECT. In this paper we first study the relationship between the geometric parameters of a MSS collimator system and the resulting resolution and sensitivity for an on-axis point at the centre of the field-of-view (FOV), assuming a continuous cylindrical detector model. The model predicts that for optimal system sensitivity and resolution, the ratio of the detector radius to slit collimator radius should be 1.3-1.5, as any further increase in this ratio results in significant deterioration in both system resolution and sensitivity. The analytical results were used to fix the geometric parameters for the three novel MSS system designs. Comparison of the three designs, asymmetric rotating collimator (ARC), asymmetric rotating detector (ARD) and symmetric rotating collimator (SRC) with variable slit spacing, suggests that the SRC system performs better in terms of the system sensitivity (5.1 x 10(-4)) for the same average resolution (6.0 mm) in comparison to designs based on an ARC (3.7 x 10(-4)) and ARD (4.2 x 10(-4)).

Entities:  

Mesh:

Year:  2009        PMID: 19436098     DOI: 10.1088/0031-9155/54/11/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

Review 1.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

Review 2.  The origins of SPECT and SPECT/CT.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-12       Impact factor: 9.236

Review 3.  SPECT detectors: the Anger Camera and beyond.

Authors:  Todd E Peterson; Lars R Furenlid
Journal:  Phys Med Biol       Date:  2011-08-09       Impact factor: 3.609

4.  Finding Optimized Conditions of Slit-Slat and Multislit-Slat Collimation for Breast Imaging.

Authors:  Daekwang Kau; Scott D Metzler
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-01       Impact factor: 1.679

Review 5.  What scans we will read: imaging instrumentation trends in clinical oncology.

Authors:  Thomas Beyer; Luc Bidaut; John Dickson; Marc Kachelriess; Fabian Kiessling; Rainer Leitgeb; Jingfei Ma; Lalith Kumar Shiyam Sundar; Benjamin Theek; Osama Mawlawi
Journal:  Cancer Imaging       Date:  2020-06-09       Impact factor: 3.909

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.