The safety and accuracy of freehand pedicle screw placement in the subaxial cervical spine: a series of 45 consecutive patients.

Jin Hoon Park1, Sang Ryong Jeon, Sung Woo Roh, Jeoung Hee Kim, Seung Chul Rhim.   

Abstract

STUDY
DESIGN: Retrospective cohort study.
OBJECTIVE: To assess the safety and accuracy of subaxial cervical pedicle screw placement with freehand technique and to report the technical nuances. SUMMARY OF BACKGROUND DATA: Although the efficacy and safety of freehand screw fixation in thoracic and lumbar vertebrae is proven, reports on this technique of screw insertion in the subaxial cervical spine are lacking.
METHODS: From March 2012 to September 2013, 45 consecutive patients underwent posterior cervical fusion. The diagnoses were trauma (22 patients), degenerative disease (18 patients), discitis/osteomyelitis (2 patients), pathological fracture (2 patients), and postlaminoplasty kyphosis (1 patient). Preoperative computed tomography (CT) was performed in all patients. We included patients whose outer diameter of the pedicle was greater than 3.0 mm. The standard entry points were modified according to the CT anatomy of each patient. A small pilot hole was fashioned at a predetermined entry point. Then, a 2.5-mm diameter curved pedicle probe was slowly inserted with a medial trajectory into the pedicle. After ball-tip probing and tapping, the screw was inserted. If ball-tip probing was suggestive of risk to neurovascular structures, conversion to a lateral mass screw was performed. Postoperatively, a CT scan was performed in all patients and the conversion rate from pedicle to lateral mass screw was recorded. The breech rate of pedicle screws was also analyzed.
RESULTS: There were 256 planned pedicle screws and 20 incidences (7.8%) of conversion to lateral mass screws. Lateral wall violation was observed in 14 pedicle screws (accuracy rate: 94.1%) on the postoperative CT scan. No medial, superior, and inferior pedicle wall violations were observed. There was no patient who developed symptoms related to vertebral artery stenosis.
CONCLUSION: Adherence to the surgical tips presented in this article may lead to safe and effective freehand placement of cervical pedicle screws. LEVEL OF EVIDENCE: 3.

Entities:  

Mesh:

Year:  2014        PMID: 24299725     DOI: 10.1097/BRS.0000000000000133

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  23 in total

1.  Application of a novel 3D drill template for cervical pedicle screw tunnel design: a cadaveric study.

Authors:  Zhengxi Yu; Guodong Zhang; Xuanhuang Chen; Xu Chen; Changfu Wu; Yijun Lin; Wenhua Huang; Haibin Lin
Journal:  Eur Spine J       Date:  2017-06-10       Impact factor: 3.134

2.  Accuracy of a dynamic surgical guidance probe for screw insertion in the cervical spine: a cadaveric study.

Authors:  Daniel Dixon; Bruce Darden; Jose Casamitjana; Karen A Weissmann; San Cristobal; David Powell; Daniel Baluch
Journal:  Eur Spine J       Date:  2016-11-14       Impact factor: 3.134

3.  An Incidental Finding of a Radiopaque Pill following Cervical Spinal Surgery in a Parkinson's Disease Patient.

Authors:  Bon Sub Gu; Soo-Jung Choi; Byoungwoo Yoo; Koon Hee Han; Jong Kyu Park; Young-Seok Lee; Jin Hoon Park
Journal:  Korean J Spine       Date:  2015-09-30

4.  Safe placement of lateral mass screw in the subaxial cervical spine: a case series.

Authors:  Di Zhang; Xianda Gao; Jiang Jiang; Fanlong Kong; Yong Shen; Wenyuan Ding; Xiufang Hao; Huixian Cui
Journal:  Int Orthop       Date:  2017-02-15       Impact factor: 3.075

5.  Lumbosacral pedicle screw placement using a fluoroscopic pedicle axis view and a cannulated tapping device.

Authors:  Toshitaka Yoshii; Takashi Hirai; Tsuyoshi Yamada; Satoshi Sumiya; Renpei Mastumoto; Tsuyoshi Kato; Mitsuhiro Enomoto; Hiroyuki Inose; Shigenori Kawabata; Kenichi Shinomiya; Atsushi Okawa
Journal:  J Orthop Surg Res       Date:  2015-05-28       Impact factor: 2.359

6.  An Assessment of the Medial Angle of Inserted Subaxial Cervical Pedicle Screw during Surgery: Practical Use of Preoperative CT Scanning and Intraoperative X-rays.

Authors:  Hong Bum Kim; Moon Kyu Lee; Young-Seok Lee; Jun-Young Sohn; Sang Ku Jung; Jin Hoon Park
Journal:  Neurol Med Chir (Tokyo)       Date:  2016-10-11       Impact factor: 1.742

7.  A Novel Patient-Specific Drill Guide Template for Pedicle Screw Insertion into the Subaxial Cervical Spine Utilizing Stereolithographic Modelling: An In Vitro Study.

Authors:  Rafael Cruz Bundoc; Giorgio De Guzman Delgado; Samuel Arsenio Munoz Grozman
Journal:  Asian Spine J       Date:  2017-02-17

8.  Comparing Accuracy of Cervical Pedicle Screw Placement between a Guidance System and Manual Manipulation: A Cadaver Study.

Authors:  Yu Cong; Nirong Bao; Jianning Zhao; Guangping Mao
Journal:  Med Sci Monit       Date:  2015-09-08

9.  Feasibility Study of Free-Hand Technique for Pedicle Screw Insertion at C7 without Fluoroscopy-Guidance.

Authors:  Gun Woo Lee; Ho-Joong Kim; Jin S Yeom; Jae-Hyung Uh; Jong-Ho Park; Ji-Hoon Lee; Dong-Wook Kim; Bo-Gun Suh
Journal:  Asian Spine J       Date:  2016-02-16

10.  In vitro study of accuracy of subaxial cervical pedicle screw insertion using calipers based on the gravity line.

Authors:  Xiang Yao; Shiqing Liu
Journal:  PLoS One       Date:  2017-07-20       Impact factor: 3.240

View more