Literature DB >> 24220954

[The interdisciplinary hybrid operation theatre. Current experience and future].

P H Richter1, F Gebhard.   

Abstract

Since June 2013 a hybrid operation theatre is used interdisciplinary in the department for surgery of Ulm University. In this operation theatre a floor-based flat panel c-arm, which is mounted on a robotic arm that can be controlled by the surgeon in a sterile environment, is linked to the operating table. Furthermore for the first time it was possible to integrate a navigation system in this setting. The interdisciplinary utilization (trauma, neurosurgery, cardiac and vascular surgery) makes this hybrid operation theatre very time and cost effective. In the orthopedic trauma department this system is mainly used for traumatic and oncologic pelvic and spinal injuries. In these anatomical regions the excellent image quality and large field of view of the robotic flat panel detector based 3D imaging combined with an intraoperative navigation system is a huge advantage. The system can also be used for complex fractures of the extremities. In the future there will be an integration of further imaging modalities and referenced holding devices in this setting.

Entities:  

Mesh:

Year:  2013        PMID: 24220954     DOI: 10.1007/s00104-013-2558-0

Source DB:  PubMed          Journal:  Chirurg        ISSN: 0009-4722            Impact factor:   0.955


  11 in total

1.  [Intraoperative magnetic resonance imaging. Fifteen years' experience in the neurosurgical hybrid operating suite].

Authors:  M Hlavac; R König; M Halatsch; C R Wirtz
Journal:  Unfallchirurg       Date:  2012-02       Impact factor: 1.000

2.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

3.  [Do we need hybrid operating theaters?: a critical appraisal].

Authors:  W A Wohlgemuth
Journal:  Radiologe       Date:  2013-06       Impact factor: 0.635

Review 4.  [The hybrid operating room. Home of high-end intraoperative imaging].

Authors:  F Gebhard; C Riepl; P Richter; A Liebold; H Gorki; R Wirtz; R König; F Wilde; A Schramm; M Kraus
Journal:  Unfallchirurg       Date:  2012-02       Impact factor: 1.000

5.  Hybrid operating room for the treatment of complex neurovascular and brachiocephalic lesions.

Authors:  Koji Iihara; Tetsu Satow; Toshinori Matsushige; Hiroharu Kataoka; Norio Nakajima; Kenji Fukuda; Makoto Isozaki; Daisuke Maruyama; Takuro Nakae; Nobuo Hashimoto
Journal:  J Stroke Cerebrovasc Dis       Date:  2012-08-29       Impact factor: 2.136

6.  The concept of a hybrid operating room: applications in cerebrovascular surgery.

Authors:  Javier Fandino; Philipp Taussky; Serge Marbacher; Carl Muroi; Michael Diepers; Ali-Reza Fathi; Luca Remonda
Journal:  Acta Neurochir Suppl       Date:  2013

7.  The outcomes of navigation-assisted bone tumour surgery: minimum three-year follow-up.

Authors:  H S Cho; J H Oh; I Han; H-S Kim
Journal:  J Bone Joint Surg Br       Date:  2012-10

8.  Hybrid operating room concept for combined diagnostics, intervention and surgery in acute type A dissection.

Authors:  Konstantinos Tsagakis; Thomas Konorza; Daniel Sebastian Dohle; Eva Kottenberg; Thomas Buck; Matthias Thielmann; Raimund Erbel; Heinz Jakob
Journal:  Eur J Cardiothorac Surg       Date:  2012-06-27       Impact factor: 4.191

9.  Computer-guidance in percutaneous screw stabilization of the iliosacral joint.

Authors:  Markus Arand; Lothar Kinzl; Florian Gebhard
Journal:  Clin Orthop Relat Res       Date:  2004-05       Impact factor: 4.176

10.  Computer-assisted planning and navigation improves cutting accuracy during simulated bone tumor surgery of the pelvis.

Authors:  Olivier Cartiaux; Xavier Banse; Laurent Paul; Bernard G Francq; Carl-Éric Aubin; Pierre-Louis Docquier
Journal:  Comput Aided Surg       Date:  2012-11-26
View more
  4 in total

1.  [Hybrid operating room : Application in trauma surgery and orthopaedics].

Authors:  Frederic Braun; Simon Peh; Matthias Weuster; Tim Klueter; Andreas Seekamp; Sebastian Lippross
Journal:  Unfallchirurg       Date:  2020-02       Impact factor: 1.000

2.  Feasibility of laser-guided percutaneous pedicle screw placement in the lumbar spine using a hybrid-OR.

Authors:  P H Richter; F Gebhard; M Salameh; K Schuetze; M Kraus
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-10       Impact factor: 2.924

3.  [Importance of intraoperative navigation in spinal surgery].

Authors:  P H Richter; F Gebhard; M Kraus
Journal:  Chirurg       Date:  2014-10       Impact factor: 0.955

4.  Image-guided procedures in the hybrid operating room: A systematic scoping review.

Authors:  Ilse M Spenkelink; Jan Heidkamp; Jurgen J Fütterer; Maroeska M Rovers
Journal:  PLoS One       Date:  2022-04-01       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.