Literature DB >> 15187858

Computer-guidance in percutaneous screw stabilization of the iliosacral joint.

Markus Arand1, Lothar Kinzl, Florian Gebhard.   

Abstract

Nine patients with instability and one patient with degeneration of the iliosacral joint were treated surgically. The posterior pelvic ring was stabilized with the assistance of an optoelectronic navigation system. Registration was ensured by using fiducial screws in the iliac crest or by collecting landmarks on the external fixator. Computed tomography scans taken postoperatively provided additional information regarding implant localization in all patients. Accurate placement of 21 of 22 implanted iliosacral screws was observed. Two of the 21 screws touched the wall of the second sacral foramen without perforating the canal. One screw perforated the anterior wall of the sacrum because the navigated guide wire was bent during implantation. The initial results indicate that computer-aided frameless navigation in surgery of the iliosacral joint can facilitate surgical performance during screw stabilization in selected patients. Two important issues must be considered in the clinical application of this technique: first, any relative migration of the iliac and sacral bone structures between computed tomography scans taken preoperatively and intraoperative navigation may result in an intolerable inaccuracy of computer guidance. Second, bending of the guide wire of the tracked power drive, which cannot be accommodated by the navigation system, will lead to misguidance; therefore, only navigated drill sleeves should be used.

Entities:  

Mesh:

Year:  2004        PMID: 15187858     DOI: 10.1097/01.blo.0000128644.46013.08

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  19 in total

1.  Factors influencing the accuracy of iliosacral screw placement in trauma patients.

Authors:  Lars Grossterlinden; Johannes Rueger; Philip Catala-Lehnen; Martin Rupprecht; Wolfgang Lehmann; Andreas Rücker; Daniel Briem
Journal:  Int Orthop       Date:  2010-07-20       Impact factor: 3.075

2.  Precision insertion of percutaneous sacroiliac screws using a novel augmented reality-based navigation system: a pilot study.

Authors:  Huixiang Wang; Fang Wang; Anthony Peng Yew Leong; Lu Xu; Xiaojun Chen; Qiugen Wang
Journal:  Int Orthop       Date:  2015-11-16       Impact factor: 3.075

3.  [Computer-assisted arthrodesis of the sacroiliac joint].

Authors:  F Gebhard; M Sarkar; G Maier; L Kinzl; M Arand
Journal:  Unfallchirurg       Date:  2005-09       Impact factor: 1.000

Review 4.  [Technique for percutaneous iliosacral screw insertion with conventional C-arm radiography].

Authors:  R E Hilgert; J Finn; H-J Egbers
Journal:  Unfallchirurg       Date:  2005-11       Impact factor: 1.000

5.  Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation.

Authors:  D Briem; W Linhart; W Lehmann; P G Begemann; G Adam; U Schumacher; D M Cullinane; J M Rueger; J Windolf
Journal:  Eur Spine J       Date:  2005-07-12       Impact factor: 3.134

6.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

7.  [Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits].

Authors:  D Briem; J Windolf; J M Rueger
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

8.  [Bony sacroiliac corridor. A virtual volume model for the accurate insertion of transarticular screws].

Authors:  T Mendel; K Appelt; P Kuhn; N Suhm
Journal:  Unfallchirurg       Date:  2008-01       Impact factor: 1.000

9.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

10.  2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series.

Authors:  Florian Gras; Ivan Marintschev; Arne Wilharm; Kajetan Klos; Thomas Mückley; Gunther O Hofmann
Journal:  BMC Musculoskelet Disord       Date:  2010-07-07       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.