Literature DB >> 28905411

Joint arterial input function and tracer kinetic parameter estimation from undersampled dynamic contrast-enhanced MRI using a model consistency constraint.

Yi Guo1, Sajan Goud Lingala1, Yannick Bliesener1, R Marc Lebel2, Yinghua Zhu1, Krishna S Nayak1.   

Abstract

PURPOSE: To develop and evaluate a model-based reconstruction framework for joint arterial input function (AIF) and kinetic parameter estimation from undersampled brain tumor dynamic contrast-enhanced MRI (DCE-MRI) data.
METHODS: The proposed method poses the tracer-kinetic (TK) model as a model consistency constraint, enabling the flexible inclusion of different TK models and TK solvers, and the joint estimation of the AIF. The proposed method is evaluated using an anatomic realistic digital reference object (DRO), and nine retrospectively down-sampled brain tumor DCE-MRI datasets. We also demonstrate application to 30-fold prospectively undersampled brain tumor DCE-MRI.
RESULTS: In DRO studies with up to 60-fold undersampling, the proposed method provided TK maps with low error that were comparable to fully sampled data and were demonstrated to be compatible with a third-party TK solver. In retrospective undersampling studies, this method provided patient-specific AIF with normalized root mean-squared-error (normalized by the 90th percentile value) less than 8% at up to 100-fold undersampling. In the 30-fold undersampled prospective study, the proposed method provided high-resolution whole-brain TK maps and patient-specific AIF.
CONCLUSION: The proposed model-based DCE-MRI reconstruction enables the use of different TK solvers with a model consistency constraint and enables joint estimation of patient-specific AIF. TK maps and patient-specific AIF with high fidelity can be reconstructed at up to 100-fold undersampling in k,t-space. Magn Reson Med 79:2804-2815, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  DCE-MRI; compressed sensing; kinetic modeling; model-based reconstruction

Mesh:

Substances:

Year:  2017        PMID: 28905411      PMCID: PMC5821580          DOI: 10.1002/mrm.26904

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  38 in total

1.  Reconstruction of dynamic image series from undersampled MRI data using data-driven model consistency condition (MOCCO).

Authors:  Julia V Velikina; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2014-11-14       Impact factor: 4.668

2.  Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging.

Authors:  Kenya Murase
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

Review 3.  Dynamic contrast-enhanced MRI in clinical trials of antivascular therapies.

Authors:  James P B O'Connor; Alan Jackson; Geoff J M Parker; Caleb Roberts; Gordon C Jayson
Journal:  Nat Rev Clin Oncol       Date:  2012-02-14       Impact factor: 66.675

4.  Creating an anthropomorphic digital MR phantom--an extensible tool for comparing and evaluating quantitative imaging algorithms.

Authors:  Ryan J Bosca; Edward F Jackson
Journal:  Phys Med Biol       Date:  2016-01-07       Impact factor: 3.609

5.  High-resolution whole-brain DCE-MRI using constrained reconstruction: Prospective clinical evaluation in brain tumor patients.

Authors:  Yi Guo; R Marc Lebel; Yinghua Zhu; Sajan Goud Lingala; Mark S Shiroishi; Meng Law; Krishna Nayak
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

6.  Respiratory Motion-Resolved Compressed Sensing Reconstruction of Free-Breathing Radial Acquisition for Dynamic Liver Magnetic Resonance Imaging.

Authors:  Hersh Chandarana; Li Feng; Justin Ream; Annie Wang; James S Babb; Kai Tobias Block; Daniel K Sodickson; Ricardo Otazo
Journal:  Invest Radiol       Date:  2015-11       Impact factor: 6.016

7.  Model selection in magnetic resonance imaging measurements of vascular permeability: Gadomer in a 9L model of rat cerebral tumor.

Authors:  James R Ewing; Stephen L Brown; Mei Lu; Swayamprava Panda; Guangliang Ding; Robert A Knight; Yue Cao; Quan Jiang; Tavarekere N Nagaraja; Jamie L Churchman; Joseph D Fenstermacher
Journal:  J Cereb Blood Flow Metab       Date:  2006-03       Impact factor: 6.200

8.  Temporal sampling requirements for the tracer kinetics modeling of breast disease.

Authors:  E Henderson; B K Rutt; T Y Lee
Journal:  Magn Reson Imaging       Date:  1998-11       Impact factor: 2.546

9.  Accelerating MR parameter mapping using sparsity-promoting regularization in parametric dimension.

Authors:  Julia V Velikina; Andrew L Alexander; Alexey Samsonov
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

10.  Blood-brain barrier breakdown in the aging human hippocampus.

Authors:  Axel Montagne; Samuel R Barnes; Melanie D Sweeney; Matthew R Halliday; Abhay P Sagare; Zhen Zhao; Arthur W Toga; Russell E Jacobs; Collin Y Liu; Lilyana Amezcua; Michael G Harrington; Helena C Chui; Meng Law; Berislav V Zlokovic
Journal:  Neuron       Date:  2015-01-21       Impact factor: 17.173

View more
  6 in total

1.  Evaluation of a novel 8-channel RX coil for speech production MRI at 0.55 T.

Authors:  Felix Muñoz; Yongwan Lim; Sophia X Cui; Helmut Stark; Krishna S Nayak
Journal:  MAGMA       Date:  2022-08-20       Impact factor: 2.533

2.  Dynamic contrast-enhanced MRI parametric mapping using high spatiotemporal resolution Golden-angle RAdial Sparse Parallel MRI and iterative joint estimation of the arterial input function and pharmacokinetic parameters.

Authors:  Yousef Mazaheri; Nathanael Kim; Yulia Lakhman; Ramin Jafari; Alberto Vargas; Ricardo Otazo
Journal:  NMR Biomed       Date:  2022-03-14       Impact factor: 4.478

3.  Bulk motion-compensated DCE-MRI for functional imaging of kidneys in newborns.

Authors:  Jaume Coll-Font; Onur Afacan; Jeanne S Chow; Richard S Lee; Alto Stemmer; Simon K Warfield; Sila Kurugol
Journal:  J Magn Reson Imaging       Date:  2019-12-14       Impact factor: 4.813

4.  Pseudo Test-Retest Evaluation of Millimeter-Resolution Whole-Brain Dynamic Contrast-enhanced MRI in Patients with High-Grade Glioma.

Authors:  Yannick Bliesener; R Marc Lebel; Jay Acharya; Richard Frayne; Krishna S Nayak
Journal:  Radiology       Date:  2021-06-08       Impact factor: 29.146

5.  Impact of (k,t) sampling on DCE MRI tracer kinetic parameter estimation in digital reference objects.

Authors:  Yannick Bliesener; Sajan G Lingala; Justin P Haldar; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2019-10-12       Impact factor: 4.668

6.  Tracer kinetic models as temporal constraints during brain tumor DCE-MRI reconstruction.

Authors:  Sajan Goud Lingala; Yi Guo; Yannick Bliesener; Yinghua Zhu; R Marc Lebel; Meng Law; Krishna S Nayak
Journal:  Med Phys       Date:  2019-11-19       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.