Literature DB >> 24202049

Factors affecting the myocardial activity acquired during exercise SPECT with a high-sensitivity cardiac CZT camera as compared with conventional Anger camera.

Antoine Verger1, Laetitia Imbert, Yalcine Yagdigul, Renaud Fay, Wassila Djaballah, François Rouzet, Nicolas Fourquet, Sylvain Poussier, Véronique Roch, Dominique Le Guludec, Gilles Karcher, Pierre-Yves Marie.   

Abstract

PURPOSE: Injected doses are difficult to optimize for exercise SPECT since they depend on the myocardial fraction of injected activity (MFI) that is detected by the camera. The aim of this study was to analyse the factors affecting MFI determined using a cardiac CZT camera as compared with those determined using conventional Anger cameras.
METHODS: Factors affecting MFI were determined and compared in patients who had consecutive exercise SPECT acquisitions with (201)Tl (84 patients) or (99m)Tc-sestamibi (87 patients) with an Anger or a CZT camera. A predictive model was validated in a group of patients routinely referred for (201)Tl (78 patients) or (99m)Tc-sestamibi (80 patients) exercise CZT SPECT.
RESULTS: The predictive model involved: (1) camera type, adjusted mean MFI being ninefold higher for CZT than for Anger SPECT, (2) tracer type, adjusted mean MFI being twofold higher for (201)Tl than for (99m)Tc-sestamibi, and (3) logarithm of body weight. The CZT SPECT model led to a +1 ± 26% error in the prediction of the actual MFI from the validation group. The mean MFI values estimated for CZT SPECT were more than twofold higher in patients with a body weight of 60 kg than in patients with a body weight of 120 kg (15.9 and 6.8 ppm for (99m)Tc-sestamibi and 30.5 and 13.1ppm for (201)Tl, respectively), and for a 14-min acquisition of up to one million myocardial counts, the corresponding injected activities were only 80 and 186 MBq for (99m)Tc-sestamibi and 39 and 91 MBq for (201)Tl, respectively.
CONCLUSION: Myocardial activities acquired during exercise CZT SPECT are strongly influenced by body weight and tracer type, and are dramatically higher than those obtained using an Anger camera, allowing very low-dose protocols to be planned, especially for (99m)Tc-sestamibi and in non-obese subjects.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24202049     DOI: 10.1007/s00259-013-2617-2

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  24 in total

Review 1.  Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: technical, physiologic, and clinical issues.

Authors:  P Kailasnath; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Jul-Aug       Impact factor: 5.952

2.  Resurrection of thallium-201 for myocardial perfusion imaging.

Authors:  H William Strauss; Dale Bailey
Journal:  JACC Cardiovasc Imaging       Date:  2009-03

3.  High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results.

Authors:  Alessia Gimelli; Matteo Bottai; Dario Genovesi; Assuero Giorgetti; Fabio Di Martino; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-02       Impact factor: 9.236

4.  A comparison of the overall first-pass kinetics of thallium-201 and technetium-99m MIBI in normoxic and low-flow ischaemic myocardium.

Authors:  A Ayalew; P Y Marie; P Menu; P M Mertes; N Hassan; N Danchin; P Olivier; G Karcher; A Bertrand
Journal:  Eur J Nucl Med       Date:  2000-11

5.  Dipyridamole and exercise SPET provide different estimates of myocardial ischaemic areas: role of the severity of coronary stenoses and of the increase in heart rate during exercise.

Authors:  N David; P Y Marie; M Angioi; R M Rodriguez; N Hassan; P Olivier; A Grentzinger; G Karcher; O Claudon; Y Juillière; N Danchin; A Bertrand
Journal:  Eur J Nucl Med       Date:  2000-07

6.  Assessing the effect of increasing injection activity for myocardial perfusion imaging in overweight patients.

Authors:  A Notghi; F X Sundram; J W O'Brien; N B Smith
Journal:  Br J Radiol       Date:  2008-06-09       Impact factor: 3.039

7.  Comparison of the myocardial uptake of a technetium-labeled isonitrile analogue and thallium.

Authors:  J A Leppo; D J Meerdink
Journal:  Circ Res       Date:  1989-09       Impact factor: 17.367

8.  Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images.

Authors:  Laetitia Imbert; Sylvain Poussier; Philippe R Franken; Bernard Songy; Antoine Verger; Olivier Morel; Didier Wolf; Alain Noel; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Med       Date:  2012-11-08       Impact factor: 10.057

9.  Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols.

Authors:  Antoine Verger; Wassila Djaballah; Nicolas Fourquet; François Rouzet; Grégoire Koehl; Laetitia Imbert; Sylvain Poussier; Renaud Fay; Véronique Roch; Dominique Le Guludec; Gilles Karcher; Pierre-Yves Marie
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-11-27       Impact factor: 9.236

10.  Influence of patient height and weight and type of stress on myocardial count density during SPECT imaging with thallium-201 and technetium 99m-sestamibi.

Authors:  M K O'Connor; E Bothun; R J Gibbons
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

View more
  15 in total

1.  Dynamic SPECT: evolution of a widely available tool for the assessment of coronary flow reserve.

Authors:  Simona Ben-Haim; Denis Agostini
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-02       Impact factor: 9.236

2.  Left ventricular ejection fraction determined with the simulation of a very low-dose CZT-SPECT protocol and an additional count-calibration on planar radionuclide angiographic data.

Authors:  Hubert Tissot; Véronique Roch; Olivier Morel; Nicolas Veran; Mathieu Perrin; Marine Claudin; Antoine Verger; Gilles Karcher; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Cardiol       Date:  2019-02-27       Impact factor: 5.952

3.  Quantification of myocardial blood flow with dynamic SPECT acquisitions: ready for prime time?

Authors:  Fabien Hyafil; François Rouzet; Dominique Le Guludec
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-11       Impact factor: 9.236

4.  Absolute myocardial blood flow quantification with SPECT/CT: is it possible?

Authors:  Piotr J Slomka; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2014-12       Impact factor: 5.952

5.  Can advances in nuclear cardiology hardware overcome the challenges of imaging obese patients?

Authors:  Ron Blankstein
Journal:  J Nucl Cardiol       Date:  2014-10-09       Impact factor: 5.952

6.  Stress-first protocol for myocardial perfusion SPECT imaging with semiconductor cameras: high diagnostic performances with significant reduction in patient radiation doses.

Authors:  Mathieu Perrin; Wassila Djaballah; Frédéric Moulin; Marine Claudin; Nicolas Veran; Laetitia Imbert; Sylvain Poussier; Olivier Morel; Cyril Besseau; Antoine Verger; Henri Boutley; Gilles Karcher; Pierre-Yves Marie
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-02-25       Impact factor: 9.236

7.  Low-dose dual-isotope procedure planed for myocardial perfusion CZT-SPECT and assessed through a head-to-head comparison with a conventional single-isotope protocol.

Authors:  Laetitia Imbert; Véronique Roch; Charles Merlin; Wassila Djaballah; Florent Cachin; Mathieu Perrin; Marine Claudin; Antoine Verger; Henri Boutley; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Cardiol       Date:  2017-05-16       Impact factor: 5.952

8.  Routine evaluation of left ventricular function using CZT-SPECT, with low injected activities and limited recording times.

Authors:  Marine Claudin; Laetitia Imbert; Wassila Djaballah; Nicolas Veran; Sylvain Poussier; Véronique Roch; Mathieu Perrin; Antoine Verger; Henri Boutley; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Cardiol       Date:  2016-09-27       Impact factor: 5.952

Review 9.  Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM).

Authors:  Denis Agostini; Pierre-Yves Marie; Simona Ben-Haim; François Rouzet; Bernard Songy; Alessandro Giordano; Alessia Gimelli; Fabien Hyafil; Roberto Sciagrà; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-19       Impact factor: 9.236

10.  Assessment of Myocardial CZT SPECT Recording in a Forward-Leaning Bikerlike Position.

Authors:  Mathieu Perrin; Véronique Roch; Marine Claudin; Antoine Verger; Henri Boutley; Gilles Karcher; Cédric Baumann; Nicolas Veran; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Med       Date:  2018-11-02       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.