Literature DB >> 25711177

Stress-first protocol for myocardial perfusion SPECT imaging with semiconductor cameras: high diagnostic performances with significant reduction in patient radiation doses.

Mathieu Perrin1, Wassila Djaballah, Frédéric Moulin, Marine Claudin, Nicolas Veran, Laetitia Imbert, Sylvain Poussier, Olivier Morel, Cyril Besseau, Antoine Verger, Henri Boutley, Gilles Karcher, Pierre-Yves Marie.   

Abstract

PURPOSE: Effective doses of 14 mSv or higher are currently being attained in patients having stress and rest myocardial perfusion imaging (MPI) single photon emission computed tomography (SPECT) performed on the same day with conventional protocols. This study aimed to assess the actual reduction in effective doses as well as diagnostic performances for MPI routinely planned with: (1) high-sensitivity cadmium zinc telluride (CZT) cameras, (2) very low injected activities and (3) a stress-first protocol where the normality of stress images may lead to avoiding rest imaging.
METHODS: During a 1-year period, 2,845 patients had MPI on a CZT camera, a single-day stress-first protocol and low injected activities (120 MBq of (99m)Tc-sestamibi at stress for 75 kg body weight and threefold higher at rest). The ability to detect > 50% coronary stenosis was assessed in a subgroup of 149 patients who also had coronary angiography, while the normalcy rate was assessed in a subgroup of 128 patients with a low pretest likelihood of coronary artery disease (<10%).
RESULTS: Overall, 33% of patients had abnormal MPI of which 34% were women and 34% were obese. The mean effective doses and the percentage of exams involving only stress images were: (1) 3.53 ± 2.10 mSv and 37% in the overall population, (2) 4.83 ± 1.56 mSv and 5% in the subgroup with angiography and (3) 1.96 ± 1.52 mSv and 71 % in the low-probability subgroup. Sensitivity and global accuracy for identifying the 106 patients with coronary stenosis were 88 and 80%, respectively, while the normalcy rate was 97 %.
CONCLUSION: When planned with a low-dose stress-first protocol on a CZT camera, MPI provides high diagnostic performances and a dramatic reduction in patient radiation doses. This reduction is even greater in low-risk subgroups with high rates of normal stress images, thus allowing the mean radiation dose to be balanced against cardiac risk in targeted populations.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25711177     DOI: 10.1007/s00259-015-3016-7

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  31 in total

1.  High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results.

Authors:  Alessia Gimelli; Matteo Bottai; Dario Genovesi; Assuero Giorgetti; Fabio Di Martino; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-02       Impact factor: 9.236

2.  Impact of combined supine and prone myocardial perfusion imaging using an ultrafast cardiac gamma camera for detection of inferolateral coronary artery disease.

Authors:  Kenji Goto; Hideo Takebayashi; Yasuki Kihara; Hiroki Yamane; Arata Hagikura; Yoshimasa Morimoto; Yuetsu Kikuta; Katsumasa Sato; Masahito Taniguchi; Shigeki Hiramatsu; Seiichi Haruta
Journal:  Int J Cardiol       Date:  2014-04-15       Impact factor: 4.164

3.  Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging: quantitative results of myocardial perfusion and left ventricular function.

Authors:  Tali Sharir; Piotr J Slomka; Sean W Hayes; Marcelo F DiCarli; Jack A Ziffer; William H Martin; Dalia Dickman; Simona Ben-Haim; Daniel S Berman
Journal:  J Am Coll Cardiol       Date:  2010-05-04       Impact factor: 24.094

4.  Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography.

Authors:  Michael Fiechter; Jelena R Ghadri; Silke M Kuest; Aju P Pazhenkottil; Mathias Wolfrum; Rene N Nkoulou; Robert Goetti; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-07-15       Impact factor: 9.236

5.  Dipyridamole and exercise SPET provide different estimates of myocardial ischaemic areas: role of the severity of coronary stenoses and of the increase in heart rate during exercise.

Authors:  N David; P Y Marie; M Angioi; R M Rodriguez; N Hassan; P Olivier; A Grentzinger; G Karcher; O Claudon; Y Juillière; N Danchin; A Bertrand
Journal:  Eur J Nucl Med       Date:  2000-07

6.  A comparison of three radionuclide myocardial perfusion tracers in clinical practice: the ROBUST study.

Authors:  Akhil Kapur; Katherine A Latus; Glyn Davies; Rhanju T Dhawan; Sian Eastick; Peter H Jarritt; George Roussakis; Melanie C Young; Constantinos Anagnostopoulos; Jimmy Bomanji; Durval C Costa; Dudley J Pennell; Elizabeth M Prvulovich; Peter J Ell; S Richard Underwood
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-10-11       Impact factor: 9.236

7.  High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging.

Authors:  Tali Sharir; Simona Ben-Haim; Konstantine Merzon; Vitali Prochorov; Dalia Dickman; Shlomo Ben-Haim; Daniel S Berman
Journal:  JACC Cardiovasc Imaging       Date:  2008-03

8.  Comparison of same-day protocols using technetium-99m-sestamibi myocardial imaging.

Authors:  J Heo; J Kegel; A S Iskandrian; V Cave; B B Iskandrian
Journal:  J Nucl Med       Date:  1992-02       Impact factor: 10.057

9.  Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images.

Authors:  Laetitia Imbert; Sylvain Poussier; Philippe R Franken; Bernard Songy; Antoine Verger; Olivier Morel; Didier Wolf; Alain Noel; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Med       Date:  2012-11-08       Impact factor: 10.057

10.  Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols.

Authors:  Antoine Verger; Wassila Djaballah; Nicolas Fourquet; François Rouzet; Grégoire Koehl; Laetitia Imbert; Sylvain Poussier; Renaud Fay; Véronique Roch; Dominique Le Guludec; Gilles Karcher; Pierre-Yves Marie
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-11-27       Impact factor: 9.236

View more
  22 in total

1.  D-SPECT: New technology, old tricks.

Authors:  Yung Hsiang Kao; Nathan Better
Journal:  J Nucl Cardiol       Date:  2015-09-25       Impact factor: 5.952

2.  Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients.

Authors:  M Lecchi; I Martinelli; O Zoccarato; C Maioli; Giovanni Lucignani; A Del Sole
Journal:  J Nucl Cardiol       Date:  2016-02-24       Impact factor: 5.952

3.  CZT cameras: A technological jump for myocardial perfusion SPECT.

Authors:  Laetitia Imbert; Pierre-Yves Marie
Journal:  J Nucl Cardiol       Date:  2015-06-25       Impact factor: 5.952

4.  Left ventricular ejection fraction determined with the simulation of a very low-dose CZT-SPECT protocol and an additional count-calibration on planar radionuclide angiographic data.

Authors:  Hubert Tissot; Véronique Roch; Olivier Morel; Nicolas Veran; Mathieu Perrin; Marine Claudin; Antoine Verger; Gilles Karcher; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Cardiol       Date:  2019-02-27       Impact factor: 5.952

5.  Which SPECT for today, which SPECT for tomorrow?

Authors:  Milena J Henzlova; W Lane Duvall
Journal:  J Nucl Cardiol       Date:  2016-04-12       Impact factor: 5.952

6.  Impact of non-specific normal databases on perfusion quantification of low-dose myocardial SPECT studies.

Authors:  Camilla Scabbio; Orazio Zoccarato; Simona Malaspina; Giovanni Lucignani; Angelo Del Sole; Michela Lecchi
Journal:  J Nucl Cardiol       Date:  2017-10-17       Impact factor: 5.952

7.  Dual isotope stress Tl-201 and rest Tc-99m CZT SPECT: Are we truly leveraging CZT technology?

Authors:  Saurabh Malhotra; Rami Doukky
Journal:  J Nucl Cardiol       Date:  2018-03-06       Impact factor: 5.952

8.  Do we need diagnostic strategies enhanced with genetic information for ischemic heart disease?

Authors:  Pierre-Yves Marie; Sophie Visvikis-Siest
Journal:  J Nucl Cardiol       Date:  2018-03-06       Impact factor: 5.952

9.  Declining radiation dose of coronary computed tomography angiography: German cardiac CT registry experience 2009-2014.

Authors:  Axel Schmermund; Mohamed Marwan; Jörg Hausleiter; Sebastian Barth; Oliver Bruder; Sebastian Kerber; Grigorius Korosoglou; Alexander Leber; Werner Moshage; Stephen Schröder; Steffen Schneider; Jochen Senges; Stephan Achenbach
Journal:  Clin Res Cardiol       Date:  2017-07-19       Impact factor: 5.460

10.  Low-dose dual-isotope procedure planed for myocardial perfusion CZT-SPECT and assessed through a head-to-head comparison with a conventional single-isotope protocol.

Authors:  Laetitia Imbert; Véronique Roch; Charles Merlin; Wassila Djaballah; Florent Cachin; Mathieu Perrin; Marine Claudin; Antoine Verger; Henri Boutley; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Cardiol       Date:  2017-05-16       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.