Literature DB >> 30145702

Quantification of myocardial blood flow with dynamic SPECT acquisitions: ready for prime time?

Fabien Hyafil1, François Rouzet1, Dominique Le Guludec2.   

Abstract

Mesh:

Year:  2018        PMID: 30145702     DOI: 10.1007/s00259-018-4127-8

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


× No keyword cloud information.
  14 in total

1.  Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 pet and a highly automated analysis program.

Authors:  Ran Klein; Jennifer M Renaud; Maria C Ziadi; Stephanie L Thorn; Andy Adler; Rob S Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2010-04-13       Impact factor: 5.952

Review 2.  Anatomic versus physiologic assessment of coronary artery disease. Role of coronary flow reserve, fractional flow reserve, and positron emission tomography imaging in revascularization decision-making.

Authors:  K Lance Gould; Nils P Johnson; Timothy M Bateman; Rob S Beanlands; Frank M Bengel; Robert Bober; Paolo G Camici; Manuel D Cerqueira; Benjamin J W Chow; Marcelo F Di Carli; Sharmila Dorbala; Henry Gewirtz; Robert J Gropler; Philipp A Kaufmann; Paul Knaapen; Juhani Knuuti; Michael E Merhige; K Peter Rentrop; Terrence D Ruddy; Heinrich R Schelbert; Thomas H Schindler; Markus Schwaiger; Stefano Sdringola; John Vitarello; Kim A Williams; Donald Gordon; Vasken Dilsizian; Jagat Narula
Journal:  J Am Coll Cardiol       Date:  2013-08-28       Impact factor: 24.094

3.  Factors affecting the myocardial activity acquired during exercise SPECT with a high-sensitivity cardiac CZT camera as compared with conventional Anger camera.

Authors:  Antoine Verger; Laetitia Imbert; Yalcine Yagdigul; Renaud Fay; Wassila Djaballah; François Rouzet; Nicolas Fourquet; Sylvain Poussier; Véronique Roch; Dominique Le Guludec; Gilles Karcher; Pierre-Yves Marie
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-08       Impact factor: 9.236

4.  Feasibility of dynamic stress 201Tl/rest 99mTc-tetrofosmin single photon emission computed tomography for quantification of myocardial perfusion reserve in patients with stable coronary artery disease.

Authors:  Sangwon Han; Young-Hak Kim; Jung-Min Ahn; Soo-Jin Kang; Jungsu S Oh; Eonwoo Shin; Changhwan Sung; Sun Young Chae; Seung-Jung Park; Gillan Grimberg; Gil Kovalski; Dae Hyuk Moon
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-06-02       Impact factor: 9.236

5.  Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia.

Authors:  Maria C Ziadi; Robert A Dekemp; Kathryn A Williams; Ann Guo; Benjamin J W Chow; Jennifer M Renaud; Terrence D Ruddy; Niroshi Sarveswaran; Rebecca E Tee; Rob S B Beanlands
Journal:  J Am Coll Cardiol       Date:  2011-08-09       Impact factor: 24.094

6.  Reporting myocardial flow reserve with PET. Ready or not, here it is! But walk before you fly!

Authors:  Daniel Juneau; Robert A deKemp; Rob S B Beanlands
Journal:  J Nucl Cardiol       Date:  2017-10-20       Impact factor: 5.952

7.  Routine Clinical Quantitative Rest Stress Myocardial Perfusion for Managing Coronary Artery Disease: Clinical Relevance of Test-Retest Variability.

Authors:  Danai Kitkungvan; Nils P Johnson; Amanda E Roby; Monika B Patel; Richard Kirkeeide; K Lance Gould
Journal:  JACC Cardiovasc Imaging       Date:  2016-12-21

8.  Absolute Myocardial Blood Flow and Flow Reserve Assessed by Gated SPECT with Cadmium-Zinc-Telluride Detectors Using 99mTc-Tetrofosmin: Head-to-Head Comparison with 13N-Ammonia PET.

Authors:  Rene Nkoulou; Tobias A Fuchs; Aju P Pazhenkottil; Silke M Kuest; Jelena R Ghadri; Julia Stehli; Michael Fiechter; Bernhard A Herzog; Oliver Gaemperli; Ronny R Buechel; Philipp A Kaufmann
Journal:  J Nucl Med       Date:  2016-06-30       Impact factor: 10.057

9.  Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study.

Authors:  Simona Ben-Haim; Venkatesh L Murthy; Christopher Breault; Rayjanah Allie; Arkadiusz Sitek; Nathaniel Roth; Jolene Fantony; Stephen C Moore; Mi-Ae Park; Marie Kijewski; Athar Haroon; Piotr Slomka; Kjell Erlandsson; Rafael Baavour; Yoel Zilberstien; Jamshed Bomanji; Marcelo F Di Carli
Journal:  J Nucl Med       Date:  2013-04-11       Impact factor: 10.057

10.  Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images.

Authors:  Laetitia Imbert; Sylvain Poussier; Philippe R Franken; Bernard Songy; Antoine Verger; Olivier Morel; Didier Wolf; Alain Noel; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Med       Date:  2012-11-08       Impact factor: 10.057

View more
  2 in total

Review 1.  Cardiovascular Imaging Techniques to Assess Microvascular Dysfunction.

Authors:  Roshin C Mathew; Jamieson M Bourque; Michael Salerno; Christopher M Kramer
Journal:  JACC Cardiovasc Imaging       Date:  2019-10-11

Review 2.  Imaging techniques for the assessment of adverse cardiac remodeling in metabolic syndrome.

Authors:  Alberto Preda; Luca Liberale; Fabrizio Montecucco
Journal:  Heart Fail Rev       Date:  2021-11-18       Impact factor: 4.654

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.