BACKGROUND AND
PURPOSE: Therapeutic strategies for patients with MS partly rely on contrast-enhanced MR imaging. Our aim was to assess the diagnostic performance of 3D turbo spin-echo MR imaging with variable refocusing flip angles at 3T for the detection of enhanced inflammatory lesions in patients with multiple sclerosis.
MATERIALS AND METHODS: Fifty-six patients with MS were prospectively investigated by using postcontrast T1-weighted axial 2D spin-echo and 3D TSE MR images. The order in which both sequences were performed was randomized. Axial reformats from 3D T1 TSE were generated to match the 2D spin-echo images. The reference standard was defined by using clinical data and all MR images available. Three separate sets of MR images (2D spin-echo images, axial reformats, and multiplanar images from 3D TSE sequences) were examined in a blinded fashion by 2 neuroradiologists separately for the detection of enhanced MS lesions. Image artifacts and contrast were evaluated.
RESULTS: No artifacts related to vascular pulsation were observed on 3D TSE images, whereas image artifacts were demonstrated on 2D spin-echo images in 41 patients. One hundred twelve enhanced MS lesions were identified in 19 patients. Sixty-four lesions were correctly diagnosed by using 2D spin-echo images; 90, by using 3D TSE axial reformatted views; and 106, by using multiplanar analysis of the 3D TSE sequence. Multiplanar analysis was 94.7% sensitive and 100% specific for the diagnosis of patients with at least 1 enhanced lesion. Contrast of enhanced MS lesions was significantly improved by using the 3D TSE sequence (P < .011).
CONCLUSIONS: The 3D TSE sequence with multiplanar analysis is a useful tool for the detection of enhanced MS lesions.

Entities:  

Mesh:

Year:  2013        PMID: 24200899      PMCID: PMC7964714          DOI: 10.3174/ajnr.A3795

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  16 in total

1.  Optimized single-slab three-dimensional spin-echo MR imaging of the brain.

Authors:  J P Mugler; S Bao; R V Mulkern; C R Guttmann; R L Robertson; F A Jolesz; J R Brookeman
Journal:  Radiology       Date:  2000-09       Impact factor: 11.105

2.  Detection of cortical lesions is dependent on choice of slice thickness in patients with multiple sclerosis.

Authors:  Ondrej Dolezal; Michael G Dwyer; Dana Horakova; Eva Havrdova; Alireza Minagar; Srivats Balachandran; Niels Bergsland; Zdenek Seidl; Manuela Vaneckova; David Fritz; Jan Krasensky; Robert Zivadinov
Journal:  Int Rev Neurobiol       Date:  2007       Impact factor: 3.230

Review 3.  MR imaging in multiple sclerosis: review and recommendations for current practice.

Authors:  K-O Lövblad; N Anzalone; A Dörfler; M Essig; B Hurwitz; L Kappos; S-K Lee; M Filippi
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-17       Impact factor: 3.825

Review 4.  MR imaging of multiple sclerosis.

Authors:  Massimo Filippi; Maria A Rocca
Journal:  Radiology       Date:  2011-06       Impact factor: 11.105

5.  Intracortical lesions in multiple sclerosis: improved detection with 3D double inversion-recovery MR imaging.

Authors:  Jeroen J G Geurts; Petra J W Pouwels; Bernard M J Uitdehaag; Chris H Polman; Frederik Barkhof; Jonas A Castelijns
Journal:  Radiology       Date:  2005-07       Impact factor: 11.105

6.  Sensitivity of immediate and delayed gadolinium-enhanced MRI after injection of 0.5 M and 1.0 M gadolinium chelates for detecting multiple sclerosis lesions.

Authors:  Ender Uysal; Sukru Mehmet Erturk; Hakan Yildirim; Feray Seleker; Muzaffer Basak
Journal:  AJR Am J Roentgenol       Date:  2007-03       Impact factor: 3.959

7.  Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis.

Authors:  Bastiaan Moraal; Stefan D Roosendaal; Petra J W Pouwels; Hugo Vrenken; Ronald A van Schijndel; Dominik S Meier; Charles R G Guttmann; Jeroen J G Geurts; Frederik Barkhof
Journal:  Eur Radiol       Date:  2008-05-29       Impact factor: 5.315

8.  Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo.

Authors:  Reed F Busse; Anja C S Brau; Anthony Vu; Charles R Michelich; Ersin Bayram; Richard Kijowski; Scott B Reeder; Howard A Rowley
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

9.  Contrast-enhanced 3-dimensional SPACE versus MP-RAGE for the detection of brain metastases: considerations with a 32-channel head coil.

Authors:  Miriam Reichert; John N Morelli; Val M Runge; Ai Tao; Ruediger von Ritschl; Andreas von Ritschl; Abraham Padua; James E Dix; Michael J Marra; Stefan O Schoenberg; Ulrike I Attenberger
Journal:  Invest Radiol       Date:  2013-01       Impact factor: 6.016

10.  Improved in vivo detection of cortical lesions in multiple sclerosis using double inversion recovery MR imaging at 3 Tesla.

Authors:  Birgit Simon; Stephan Schmidt; Carsten Lukas; Jürgen Gieseke; Frank Träber; Dirk L Knol; Winfried A Willinek; Jeroen J G Geurts; Hans H Schild; Frederik Barkhof; Mike P Wattjes
Journal:  Eur Radiol       Date:  2010-01-22       Impact factor: 5.315

View more
  6 in total

1.  Brain Tumor-Enhancement Visualization and Morphometric Assessment: A Comparison of MPRAGE, SPACE, and VIBE MRI Techniques.

Authors:  L Danieli; G C Riccitelli; D Distefano; E Prodi; E Ventura; A Cianfoni; A Kaelin-Lang; M Reinert; E Pravatà
Journal:  AJNR Am J Neuroradiol       Date:  2019-06-20       Impact factor: 3.825

2.  MS lesions are better detected with 3D T1 gradient-echo than with 2D T1 spin-echo gadolinium-enhanced imaging at 3T.

Authors:  A Crombé; M Saranathan; A Ruet; M Durieux; E de Roquefeuil; J C Ouallet; B Brochet; V Dousset; T Tourdias
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-06       Impact factor: 3.825

Review 3.  Evidence-based guidelines: MAGNIMS consensus guidelines on the use of MRI in multiple sclerosis-clinical implementation in the diagnostic process.

Authors:  Àlex Rovira; Mike P Wattjes; Mar Tintoré; Carmen Tur; Tarek A Yousry; Maria P Sormani; Nicola De Stefano; Massimo Filippi; Cristina Auger; Maria A Rocca; Frederik Barkhof; Franz Fazekas; Ludwig Kappos; Chris Polman; David Miller; Xavier Montalban
Journal:  Nat Rev Neurol       Date:  2015-07-07       Impact factor: 42.937

4.  Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI.

Authors:  F X Aymerich; C Auger; P Alcaide-Leon; D Pareto; E Huerga; J F Corral; R Mitjana; J Sastre-Garriga; X Montalban; A Rovira
Journal:  Eur Radiol       Date:  2016-07-25       Impact factor: 5.315

5.  Nonlesional Sources of Contrast Enhancement on Postgadolinium "Black-Blood" 3D T1-SPACE Images in Patients with Multiple Sclerosis.

Authors:  L Danieli; L Roccatagliata; D Distefano; E Prodi; G C Riccitelli; A Diociasi; L Carmisciano; A Cianfoni; T Bartalena; A Kaelin-Lang; C Gobbi; C Zecca; E Pravatà
Journal:  AJNR Am J Neuroradiol       Date:  2022-05-26       Impact factor: 4.966

6.  T1w dark blood imaging improves detection of contrast enhancing lesions in multiple sclerosis.

Authors:  Christian Thaler; Tanja Schneider; Jan Sedlacik; Daniel Kutzner; Jan-Patrick Stellmann; Christoph Heesen; Jens Fiehler; Susanne Siemonsen
Journal:  PLoS One       Date:  2017-08-10       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.