Literature DB >> 17250577

The presence of Pseudomonas aeruginosa in the dental unit waterline systems of teaching clinics.

A S Al-Hiyasat1, S Y Ma'ayeh, M Y Hindiyeh, Y S Khader.   

Abstract

OBJECTIVE: The objective of this study was to evaluate the extent of Pseudomonas aeruginosa contamination of Dental Unit Water (DUW) at a Dental Teaching Center in Jordan.
METHODS: Water samples were collected from 30 dental units, 10 from each of three teaching clinics, namely conservative dentistry, periodontology, and prosthodontics. Samples were collected from the outlet of the air/water syringe, high-speed handpiece and water cup filler, at the beginning of the working day (before use), after 2 min flushing, and at midday.
RESULTS: P. aeruginosa was detected in 86.7% (26/30) of the dental units at the beginning of the working day, and in 73.3% (22/30) after 2 min of flushing and at midday. Conservative dentistry units had the highest counts, followed by periodontology and prosthodontics (P<0.05). Overall, the highest counts (log10 count CFU ml-1) were at the beginning of the working day (1.38+/-1.05), and the lowest counts after flushing for 2 min (1.10+/-1.03), and higher numbers were seen again at midday (1.15+/-1.04) (P<0.05).
CONCLUSIONS: 86.7% of the dental units were contaminated with P. aeruginosa, the conservative dentistry units had the highest amount of contamination. Flushing the DUW for 2 min significantly reduced the counts of P. aeruginosa.

Entities:  

Mesh:

Year:  2007        PMID: 17250577     DOI: 10.1111/j.1601-5037.2007.00221.x

Source DB:  PubMed          Journal:  Int J Dent Hyg        ISSN: 1601-5029            Impact factor:   2.477


  9 in total

1.  Pseudomonas aeruginosa and Achromobacter sp. clonal selection leads to successive waves of contamination of water in dental care units.

Authors:  Fatima Abdouchakour; Chloé Dupont; Delphine Grau; Fabien Aujoulat; Patricia Mournetas; Hélène Marchandin; Sylvie Parer; Philippe Gibert; Jean Valcarcel; Estelle Jumas-Bilak
Journal:  Appl Environ Microbiol       Date:  2015-08-21       Impact factor: 4.792

2.  Evaluation of antimicrobial-antibiofilm activity of a hydrogen peroxide decontaminating system used in dental unit water lines.

Authors:  Germano Orrù; Susanna Del Nero; Enrica Tuveri; Maria Laura Ciusa; Francesca Pilia; Matteo Erriu; Ginevra Orrù; Manuele Liciardi; Vincenzo Piras; Gloria Denotti
Journal:  Open Dent J       Date:  2010-07-20

3.  Investigation of the bacterial load and antibiotic susceptibility of dental units.

Authors:  Nihal Dogruöz Güngör; Duygu Göksay Kadaifçiler; Oya Öztan Peker
Journal:  Environ Monit Assess       Date:  2013-11-06       Impact factor: 2.513

4.  Growth and identification of bacteria in N-halamine dental unit waterline tubing using an ultrapure water source.

Authors:  Nuala Porteous; Jie Luo; Monica Hererra; John Schoolfield; Yuyu Sun
Journal:  Int J Microbiol       Date:  2011-12-15

5.  Economic comparison of conventional maintenance and electrochemical oxidation to warrant water safety in dental unit water lines.

Authors:  Sebastian Fischer; Georg Meyer; Axel Kramer
Journal:  GMS Krankenhhyg Interdiszip       Date:  2012-04-04

6.  Three key factors influencing the bacterial contamination of dental unit waterlines: a 6-year survey from 2012 to 2017.

Authors:  Xue-Yue Ji; Chun-Nan Fei; Ying Zhang; Jun Liu; He Liu; Jia Song
Journal:  Int Dent J       Date:  2018-12-19       Impact factor: 2.607

7.  Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs.

Authors:  Rossella Briancesco; Stefania Paduano; Maurizio Semproni; Luca Vitanza; Lucia Bonadonna
Journal:  Int J Environ Res Public Health       Date:  2020-11-09       Impact factor: 3.390

8.  Dental unit water content and antibiotic resistance of Pseudomonas aeruginosa and Pseudomonas species: a case study.

Authors:  M Tesauro; M Consonni; I Grappasonni; G Lodi; R Mattina
Journal:  J Oral Microbiol       Date:  2022-08-23       Impact factor: 5.833

9.  Suction Hoses of Dental Units as a Potential Source of Microbial Contamination.

Authors:  Tayebeh Zeinali; Elham Bozorgvar; Moghgan Habibi; Narjes Akbari; Behnam Barikbin
Journal:  Oman Med J       Date:  2020-03-16
  9 in total