Literature DB >> 24179630

Real-time dosimetry in external beam radiation therapy.

Ramachandran Prabhakar1.   

Abstract

With growing complexity in radiotherapy treatment delivery, it has become mandatory to check each and every treatment plan before implementing clinically. This process is currently administered by an independent secondary check of all treatment parameters and as a pre-treatment quality assurance (QA) check for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy treatment plans. Although pre-treatment IMRT QA is aimed to ensure the correct dose is delivered to the patient, it does not necessarily predict the clinically relevant patient dose errors. During radiotherapy, treatment uncertainties can affect tumor control and may increase complications to surrounding normal tissues. To combat this, image guided radiotherapy is employed to help ensure the plan conditions are mimicked on the treatment machine. However, it does not provide information on actual delivered dose to the tumor volume. Knowledge of actual dose delivered during treatment aid in confirming the prescribed dose and also to replan/reassess the treatment in situations where the planned dose is not delivered as expected by the treating physician. Major accidents in radiotherapy would have been averted if real time dosimetry is incorporated as part of the routine radiotherapy procedure. Of late real-time dosimetry is becoming popular with complex treatments in radiotherapy. Real-time dosimetry can be either in the form of point doses or planar doses or projected on to a 3D image dataset to obtain volumetric dose. They either provide entrance dose or exit dose or dose inside the natural cavities of a patient. In external beam radiotherapy, there are four different established platforms whereby the delivered dose information can be obtained: (1) Collimator; (2) Patient; (3) Couch; and (4) Electronic Portal Imaging Device. Current real-time dosimetric techniques available in radiotherapy have their own advantages and disadvantages and a combination of one or more of these methods provide vital information about the actual dose delivered to radiotherapy patients.

Entities:  

Keywords:  Cancer; Dosimetry; External beam; Radiotherapy; Real-time

Year:  2013        PMID: 24179630      PMCID: PMC3812446          DOI: 10.4329/wjr.v5.i10.352

Source DB:  PubMed          Journal:  World J Radiol        ISSN: 1949-8470


  27 in total

1.  The radiation overexposure of radiotherapy patients in Panama 15 June 2001.

Authors:  S Vatnitsky; P Ortiz Lopez; J Izewska; A Meghzifene; V Levin
Journal:  Radiother Oncol       Date:  2001-09       Impact factor: 6.280

2.  A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy.

Authors:  Ramachandran Prabhakar; Jim Cramb; Tomas Kron
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

3.  Real-time scintillation array dosimetry for radiotherapy: the advantages of photomultiplier detectors.

Authors:  Paul Z Y Liu; Natalka Suchowerska; Peter Abolfathi; David R McKenzie
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

4.  Radiotherapy near misses, incidents and errors: radiotherapy incident at Glasgow.

Authors:  M V Williams
Journal:  Clin Oncol (R Coll Radiol)       Date:  2007-02       Impact factor: 4.126

5.  Real-time motion-adaptive-optimization (MAO) in TomoTherapy.

Authors:  Weiguo Lu; Mingli Chen; Kenneth J Ruchala; Quan Chen; Katja M Langen; Patrick A Kupelian; Gustavo H Olivera
Journal:  Phys Med Biol       Date:  2009-06-23       Impact factor: 3.609

6.  What went wrong at Exeter?

Authors:  J S Tobias
Journal:  BMJ       Date:  1988-08-06

7.  Clinical application of GAFCHROMIC EBT film for in vivo dose measurements of total body irradiation radiotherapy.

Authors:  Fan-Chi Su; Chengyu Shi; Niko Papanikolaou
Journal:  Appl Radiat Isot       Date:  2007-10-10       Impact factor: 1.513

8.  Hazards of dose escalation in prostate cancer radiotherapy.

Authors:  Deborah Kuban; Alan Pollack; Eugene Huang; Larry Levy; Lei Dong; George Starkschall; Isaac Rosen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-12-01       Impact factor: 7.038

9.  In-vivo dosimetry from total body irradiation patients (2000-2006): results and analysis.

Authors:  C M Lancaster; J C Crosbie; S R Davis
Journal:  Australas Phys Eng Sci Med       Date:  2008-09       Impact factor: 1.430

10.  A technique for pediatric total skin electron irradiation.

Authors:  Qinan Bao; Brian A Hrycushko; Joseph P Dugas; Frederick H Hager; Timothy D Solberg
Journal:  Radiat Oncol       Date:  2012-03-20       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.