Literature DB >> 18023587

Clinical application of GAFCHROMIC EBT film for in vivo dose measurements of total body irradiation radiotherapy.

Fan-Chi Su1, Chengyu Shi, Niko Papanikolaou.   

Abstract

The GAFCHROMIC EBT film model is a fairly new film product designed for absorbed dose measurements of high-energy photon beams. In vivo dosimetry for total body irradiation (TBI) remains a challenging task due to the extended source-to-surface distance (SSD), low dose rates, and the use of beam spoilers. EBT film samples were used for dose measurements on an anthropomorphic phantom using a TBI setup. Additionally, in vivo measurements were obtained for two TBI patients. Phantom results verified the suitability of the EBT film for TBI treatment in terms of accuracy, reproducibility, and dose linearity. Doses measured were compared to conventional dosimeter measurements using thermoluminescent dosimeters (TLDs), resulting in an agreement of 4.1% and 6.7% for the phantom and patient measurements, respectively. Results obtained from the phantom and patients confirm that GAFCHROMIC EBT films are a suitable alternative to TLDs as an in vivo dosimeter in TBI radiotherapy.

Entities:  

Mesh:

Year:  2007        PMID: 18023587     DOI: 10.1016/j.apradiso.2007.09.015

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  7 in total

1.  Real-time dosimetry in external beam radiation therapy.

Authors:  Ramachandran Prabhakar
Journal:  World J Radiol       Date:  2013-10-28

2.  Is the in vivo dosimetry with the OneDosePlusTM system able to detect intra-fraction motion? A retrospective analysis of in vivo data from breast and prostate patients.

Authors:  Maria Daniela Falco; Marco D'Andrea; Alessia Lo Bosco; Mauro Rebuzzi; Elisabetta Ponti; Barbara Tolu; Grazia Tortorelli; Rosaria Barbarino; Luana Di Murro; Riccardo Santoni
Journal:  Radiat Oncol       Date:  2012-06-20       Impact factor: 3.481

3.  A study on comparison of Gafchromic EBT2 film response under single and cumulative exposure conditions.

Authors:  K Ganapathy; P G G Kurup; V Murali; M Muthukumaran; J Velmurugan
Journal:  J Med Phys       Date:  2013-10

4.  Methodology for radiochromic film analysis using FilmQA Pro and ImageJ.

Authors:  Michelle E Howard; Michael G Herman; Michael P Grams
Journal:  PLoS One       Date:  2020-05-21       Impact factor: 3.240

5.  Build-up material requirements in clinical dosimetry during total body irradiation treatments.

Authors:  Martin Butson; Dane Pope; Mamoon Haque; Tom Chen; Guangli Song; May Whitaker
Journal:  J Med Phys       Date:  2016 Apr-Jun

6.  Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density.

Authors:  Elsa Y León Marroquin; José A Herrera González; Miguel A Camacho López; José E Villarreal Barajas; Olivia A García-Garduño
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

7.  Monte Carlo simulations of EBT3 film dose deposition for percentage depth dose (PDD) curve evaluation.

Authors:  Spencer M Robinson; Nolan Esplen; Derek Wells; Magdalena Bazalova-Carter
Journal:  J Appl Clin Med Phys       Date:  2020-11-06       Impact factor: 2.102