A technique for estimating the occlusion effect for frequencies below 125 Hz.

Michael A Stone1, Anna M Paul, Patrick Axon, Brian C J Moore.   

Abstract

OBJECTIVES: The level of bone-conducted sound in the auditory meatus is increased at low frequencies by occlusion of the meatus, for example, by the earmold of a hearing aid (HA). Physical measures of this "occlusion effect" (OE) require vibration of the skull. In previous research, either self-voicing or audiometric bone conduction vibrators were used to produce this vibration, with the result that the OE could not be measured for frequencies below 125 Hz. However, frequencies below this can be important for music perception by HA users. The objective was to develop and evaluate a method that gives a lower-bound estimate of the OE for frequencies below 125 Hz.
DESIGN: A low-noise amplifier with extended low-frequency response was used to record the output of a miniature microphone inserted into the meatus of participants. The signal came from sounds of the heartbeat and blood flow of the participant, transmitted via bone conduction through the walls of the meatus. A simultaneous recording was made of the carotid pulse to permit time-locked averaging (and hence noise reduction) of the microphone signal. Recordings were made from 7 otologically and audiometrically normal participants, using clinical probe tips to produce the occlusion. Recordings were also made from an overlapping group of 9 participants, using fast-setting impression material to provide a more consistent degree of occlusion. The difference in level of the recorded signal for unoccluded and occluded conditions provided a lower bound for the magnitude of the OE.
RESULTS: The mean OE increased with decreasing frequency, reaching a plateau of about 40 dB for frequencies below 40 Hz. For some individual recordings, the OE reached 50 dB for frequencies below 20 Hz. With occlusion, the heartbeat became audible for most participants.
CONCLUSIONS: The OE can be very large at low frequencies. The use of HAs with closed fittings, which may be used either to prevent acoustic feedback or to allow amplification of low frequencies, may lead to an unacceptable OE. The authors suggest reducing the OE with the use of a seal deep in the meatus, where the wall of the meatus is more rigid.

Entities:  

Mesh:

Year:  2014        PMID: 24141593      PMCID: PMC4197401          DOI: 10.1097/AUD.0b013e31829f2672

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  15 in total

1.  Perceived naturalness of spectrally distorted speech and music.

Authors:  Brian C J Moore; Chin-Tuan Tan
Journal:  J Acoust Soc Am       Date:  2003-07       Impact factor: 1.840

2.  Speech and melody recognition in binaurally combined acoustic and electric hearing.

Authors:  Ying-Yee Kong; Ginger S Stickney; Fan-Gang Zeng
Journal:  J Acoust Soc Am       Date:  2005-03       Impact factor: 1.840

3.  The benefits of combining acoustic and electric stimulation for the recognition of speech, voice and melodies.

Authors:  Michael F Dorman; Rene H Gifford; Anthony J Spahr; Sharon A McKarns
Journal:  Audiol Neurootol       Date:  2007-11-29       Impact factor: 1.854

4.  The influence of receiver size on magnitude of acoustic and perceived measures of occlusion.

Authors:  Kristin A Vasil-Dilaj; Kathleen M Cienkowski
Journal:  Am J Audiol       Date:  2011-01-28       Impact factor: 1.493

5.  Sound-pressure measurements in the cochlear vestibule of human-cadaver ears.

Authors:  S Puria; W T Peake; J J Rosowski
Journal:  J Acoust Soc Am       Date:  1997-05       Impact factor: 1.840

6.  Maturation of the occlusion effect: a bone conduction auditory steady state response study in infants and adults with normal hearing.

Authors:  Susan A Small; Ning Hu
Journal:  Ear Hear       Date:  2011 Nov-Dec       Impact factor: 3.570

7.  Assessment of sound in the ear canal caused by movement of the jaw relative to the skull.

Authors:  P Howell; M Williams; H Dix
Journal:  Scand Audiol       Date:  1988

8.  Judgments of hearing aid processed music.

Authors:  J R Franks
Journal:  Ear Hear       Date:  1982 Jan-Feb       Impact factor: 3.570

9.  Modeling binaural loudness.

Authors:  Brian C J Moore; Brian R Glasberg
Journal:  J Acoust Soc Am       Date:  2007-03       Impact factor: 1.840

Review 10.  Effects of bandwidth, compression speed, and gain at high frequencies on preferences for amplified music.

Authors:  Brian C J Moore
Journal:  Trends Amplif       Date:  2012-11-19
View more
  4 in total

1.  On Zwicker tones and musical pitch in the likely absence of phase locking corresponding to the pitch.

Authors:  Hedwig E Gockel; Robert P Carlyon
Journal:  J Acoust Soc Am       Date:  2016-10       Impact factor: 1.840

Review 2.  Development and current status of the "Cambridge" loudness models.

Authors:  Brian C J Moore
Journal:  Trends Hear       Date:  2014-10-13       Impact factor: 3.293

3.  Occlusion Effect in Response to Stimulation by Soft Tissue Conduction-Implications.

Authors:  Miriam Geal-Dor; Cahtia Adelman; Shai Chordekar; Haim Sohmer
Journal:  Audiol Res       Date:  2020-12-04

Review 4.  How Is the Cochlea Activated in Response to Soft Tissue Auditory Stimulation in the Occluded Ear?

Authors:  Miriam Geal-Dor; Haim Sohmer
Journal:  Audiol Res       Date:  2021-07-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.