Literature DB >> 24095841

Multi-coil magnetic field modeling.

Christoph Juchem1, Dan Green, Robin A de Graaf.   

Abstract

The performance of multi-coil (MC) magnetic field modeling is compared to dedicated wire patterns for the generation of spherical harmonic (SH) shapes as these are the workhorse for spatial encoding and magnetic field homogenization in MR imaging and spectroscopy. To this end, an example 48 channel MC setup is analyzed and shown to be capable of generating all first through fourth order SH shapes over small and large regions-of-interest relevant for MR investigations. The MC efficiency for the generation of linear gradient fields shares the same order of magnitude with classic and state-of-the-art SH gradient coils. MC field modeling becomes progressively more efficient with the synthesis of more complex field shapes that require the combination of multiple SH terms. The possibility of a region-specific optimization of both magnetic field shapes and generation performance with the MC approach are discussed with emphasis on the possible trade-off between the field accuracy and generation efficiency. MC shimming has been shown previously to outperform current SH shimming. Along with the efficiency gains of MC shimming shown here, the MC concept has the potential to (1) replace conventional shim systems that are based on sets of dedicated SH coils and (2) allow optimal object-specific shim solutions similar to object-specific RF coils.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Accuracy; Efficiency; Magnetic fields; Modeling; Spherical harmonic functions

Mesh:

Year:  2013        PMID: 24095841      PMCID: PMC3866212          DOI: 10.1016/j.jmr.2013.08.015

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  15 in total

1.  Low-gradient single-sided NMR sensor for one-shot profiling of human skin.

Authors:  Maxime Van Landeghem; Ernesto Danieli; Juan Perlo; Bernhard Blümich; Federico Casanova
Journal:  J Magn Reson       Date:  2011-12-28       Impact factor: 2.229

2.  Gradient coil design using active magnetic screening.

Authors:  R Bowtell; P Mansfield
Journal:  Magn Reson Med       Date:  1991-01       Impact factor: 4.668

3.  Fully automated shim mapping method for spectroscopic imaging of the mouse brain at 9.4 T.

Authors:  Naoyuki Miyasaka; Kan Takahashi; Hoby P Hetherington
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

4.  Magnetic field modeling with a set of individual localized coils.

Authors:  Christoph Juchem; Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  J Magn Reson       Date:  2010-03-11       Impact factor: 2.229

5.  Minimax current density gradient coils: analysis of coil performance and heating.

Authors:  Michael S Poole; Peter T While; Hector Sanchez Lopez; Stuart Crozier
Journal:  Magn Reson Med       Date:  2011-12-28       Impact factor: 4.668

6.  Multicoil shimming of the mouse brain.

Authors:  Christoph Juchem; Peter B Brown; Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-03-25       Impact factor: 4.668

7.  Quadrupole gradient coil design and optimization: a printed circuit board approach.

Authors:  K Chu; B K Rutt
Journal:  Magn Reson Med       Date:  1994-06       Impact factor: 4.668

8.  Magnet field profiling: analysis and correcting coil design.

Authors:  F Roméo; D I Hoult
Journal:  Magn Reson Med       Date:  1984-03       Impact factor: 4.668

9.  Dynamic Shimming of the Human Brain at 7 Tesla.

Authors:  Christoph Juchem; Terence W Nixon; Piotr Diduch; Douglas L Rothman; Piotr Starewicz; Robin A de Graaf
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2010-07-06       Impact factor: 1.176

10.  Automatic, localized in vivo adjustment of all first- and second-order shim coils.

Authors:  R Gruetter
Journal:  Magn Reson Med       Date:  1993-06       Impact factor: 4.668

View more
  16 in total

1.  Performance evaluation of matrix gradient coils.

Authors:  Feng Jia; Gerrit Schultz; Frederik Testud; Anna Masako Welz; Hans Weber; Sebastian Littin; Huijun Yu; Jürgen Hennig; Maxim Zaitsev
Journal:  MAGMA       Date:  2015-12-14       Impact factor: 2.310

2.  A 32-channel combined RF and B0 shim array for 3T brain imaging.

Authors:  Jason P Stockmann; Thomas Witzel; Boris Keil; Jonathan R Polimeni; Azma Mareyam; Cristen LaPierre; Kawin Setsompop; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2015-02-17       Impact factor: 4.668

3.  The public multi-coil information (PUMCIN) policy.

Authors:  Christoph Juchem; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2016-12-01       Impact factor: 4.668

4.  Dynamic multi-coil technique (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla.

Authors:  Christoph Juchem; S Umesh Rudrapatna; Terence W Nixon; Robin A de Graaf
Journal:  Neuroimage       Date:  2014-11-08       Impact factor: 6.556

Review 5.  Gradient and shim technologies for ultra high field MRI.

Authors:  Simone A Winkler; Franz Schmitt; Hermann Landes; Joshua de Bever; Trevor Wade; Andrew Alejski; Brian K Rutt
Journal:  Neuroimage       Date:  2016-11-30       Impact factor: 6.556

6.  Analysis of coil element distribution and dimension for matrix gradient coils.

Authors:  Hongyan He; Shufeng Wei; Huixian Wang; Wenhui Yang
Journal:  MAGMA       Date:  2022-06-11       Impact factor: 2.310

7.  Multi-slice MRI with the dynamic multi-coil technique.

Authors:  Christoph Juchem; Omar M Nahhass; Terence W Nixon; Robin A de Graaf
Journal:  NMR Biomed       Date:  2015-09-30       Impact factor: 4.044

Review 8.  B0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy.

Authors:  Christoph Juchem; Robin A de Graaf
Journal:  Anal Biochem       Date:  2016-06-09       Impact factor: 3.365

9.  DYNAmic Multi-coIl TEchnique (DYNAMITE) shimming of the rat brain at 11.7 T.

Authors:  Christoph Juchem; Peter Herman; Basavaraju G Sanganahalli; Peter B Brown; Scott McIntyre; Terence W Nixon; Dan Green; Fahmeed Hyder; Robin A de Graaf
Journal:  NMR Biomed       Date:  2014-05-17       Impact factor: 4.044

10.  Comparision of new element designs for combined RF-Shim arrays at 7 T.

Authors:  Simone A Winkler; Paul A Warr; Jason P Stockmann; Azma Mareyam; Boris Keil; Ronald D Watkins; Lawrence L Wald; Brian K Rutt
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2018-06-07       Impact factor: 1.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.