Literature DB >> 27293215

B0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy.

Christoph Juchem1, Robin A de Graaf2.   

Abstract

The homogenization of B0 conditions is necessary for every magnetic resonance spectroscopy (MRS) investigation. Its direct consequence is narrow spectral lines, on which reliable separation and quantification of biochemicals, and thus experimentally obtainable metabolic information, fundamentally relies. Besides spectral linewidth, unwanted B0 inhomogeneity also impairs other aspects of the MRS experiment, such as water suppression and editing efficiency, that rely on exact frequency definition. Therefore, experimental B0 homogenization, called B0 shimming, is mandatory for meaningful MRS, and high-level B0 shimming is arguably one of the most important ingredients for successful MRS investigations. In this review, we describe the relevance of B0 homogeneity for in vivo MRS and summarize common concepts and specific solutions for its experimental optimization.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  B(0) field modeling; B(0) homogeneity; B­(0) shimming; DYNAMITE; FASTMAP; Spherical harmonic functions

Mesh:

Year:  2016        PMID: 27293215      PMCID: PMC5148734          DOI: 10.1016/j.ab.2016.06.003

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  58 in total

1.  Proton T2 relaxation study of water, N-acetylaspartate, and creatine in human brain using Hahn and Carr-Purcell spin echoes at 4T and 7T.

Authors:  Shalom Michaeli; Michael Garwood; Xiao-Hong Zhu; Lance DelaBarre; Peter Andersen; Gregor Adriany; Hellmut Merkle; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

2.  Real-time autoshimming for echo planar timecourse imaging.

Authors:  Heidi A Ward; Stephen J Riederer; Clifford R Jack
Journal:  Magn Reson Med       Date:  2002-11       Impact factor: 4.668

Review 3.  Handling macromolecule signals in the quantification of the neurochemical profile.

Authors:  Cristina Cudalbu; Vladimir Mlynárik; Rolf Gruetter
Journal:  J Alzheimers Dis       Date:  2012       Impact factor: 4.472

4.  Real-time shimming to compensate for respiration-induced B0 fluctuations.

Authors:  P van Gelderen; J A de Zwart; P Starewicz; R S Hinks; J H Duyn
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

5.  1H-MRS of the macaque monkey primary visual cortex at 7 T: strategies and pitfalls of shimming at the brain surface.

Authors:  Christoph Juchem; Nikos K Logothetis; Josef Pfeuffer
Journal:  Magn Reson Imaging       Date:  2007-04-27       Impact factor: 2.546

6.  Field camera measurements of gradient and shim impulse responses using frequency sweeps.

Authors:  S Johanna Vannesjo; Benjamin E Dietrich; Matteo Pavan; David O Brunner; Bertram J Wilm; Christoph Barmet; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2013-09-16       Impact factor: 4.668

7.  Real-time feedback for spatiotemporal field stabilization in MR systems.

Authors:  Yolanda Duerst; Bertram J Wilm; Benjamin E Dietrich; S Johanna Vannesjo; Christoph Barmet; Thomas Schmid; David O Brunner; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2014-03-13       Impact factor: 4.668

8.  Multicoil shimming of the mouse brain.

Authors:  Christoph Juchem; Peter B Brown; Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-03-25       Impact factor: 4.668

9.  Real-time motion and B0 corrected single voxel spectroscopy using volumetric navigators.

Authors:  Aaron T Hess; M Dylan Tisdall; Ovidiu C Andronesi; Ernesta M Meintjes; André J W van der Kouwe
Journal:  Magn Reson Med       Date:  2011-03-04       Impact factor: 4.668

10.  Tactile and non-tactile sensory paradigms for fMRI and neurophysiologic studies in rodents.

Authors:  Basavaraju G Sanganahalli; Christopher J Bailey; Peter Herman; Fahmeed Hyder
Journal:  Methods Mol Biol       Date:  2009
View more
  23 in total

1.  Hardware Considerations for Preclinical Magnetic Resonance of the Kidney.

Authors:  Paula Ramos Delgado; Ekkehard Küstermann; André Kühne; Jason M Millward; Thoralf Niendorf; Andreas Pohlmann; Martin Meier
Journal:  Methods Mol Biol       Date:  2021

2.  An orthogonal shim coil for 3T brain imaging.

Authors:  Jiazheng Zhou; Jason P Stockmann; Nicolas Arango; Thomas Witzel; Klaus Scheffler; Lawrence L Wald; Fa-Hsuan Lin
Journal:  Magn Reson Med       Date:  2019-10-21       Impact factor: 4.668

3.  The public multi-coil information (PUMCIN) policy.

Authors:  Christoph Juchem; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2016-12-01       Impact factor: 4.668

4.  Protein-Engineered Nanoscale Micelles for Dynamic 19F Magnetic Resonance and Therapeutic Drug Delivery.

Authors:  Lindsay K Hill; Joseph A Frezzo; Priya Katyal; Dung Minh Hoang; Zakia Ben Youss Gironda; Cynthia Xu; Xuan Xie; Erika Delgado-Fukushima; Youssef Z Wadghiri; Jin Kim Montclare
Journal:  ACS Nano       Date:  2019-02-19       Impact factor: 15.881

Review 5.  In vivo B0 field shimming methods for MRI at 7T.

Authors:  Jason P Stockmann; Lawrence L Wald
Journal:  Neuroimage       Date:  2017-06-07       Impact factor: 6.556

Review 6.  Methodological consensus on clinical proton MRS of the brain: Review and recommendations.

Authors:  Martin Wilson; Ovidiu Andronesi; Peter B Barker; Robert Bartha; Alberto Bizzi; Patrick J Bolan; Kevin M Brindle; In-Young Choi; Cristina Cudalbu; Ulrike Dydak; Uzay E Emir; Ramon G Gonzalez; Stephan Gruber; Rolf Gruetter; Rakesh K Gupta; Arend Heerschap; Anke Henning; Hoby P Hetherington; Petra S Huppi; Ralph E Hurd; Kejal Kantarci; Risto A Kauppinen; Dennis W J Klomp; Roland Kreis; Marijn J Kruiskamp; Martin O Leach; Alexander P Lin; Peter R Luijten; Małgorzata Marjańska; Andrew A Maudsley; Dieter J Meyerhoff; Carolyn E Mountford; Paul G Mullins; James B Murdoch; Sarah J Nelson; Ralph Noeske; Gülin Öz; Julie W Pan; Andrew C Peet; Harish Poptani; Stefan Posse; Eva-Maria Ratai; Nouha Salibi; Tom W J Scheenen; Ian C P Smith; Brian J Soher; Ivan Tkáč; Daniel B Vigneron; Franklyn A Howe
Journal:  Magn Reson Med       Date:  2019-03-28       Impact factor: 4.668

7.  Interleaved 31 P MRS imaging of human frontal and occipital lobes using dual RF coils in combination with single-channel transmitter-receiver and dynamic B0 shimming.

Authors:  Byeong-Yeul Lee; Xiao-Hong Zhu; Myung Kyun Woo; Gregor Adriany; Scott Schillak; Wei Chen
Journal:  NMR Biomed       Date:  2017-10-26       Impact factor: 4.044

8.  Neurochemical differences between bipolar disorder type I and II in superior temporal cortices: A proton magnetic resonance spectroscopy study.

Authors:  Murat İlhan Atagün; Elif Muazzez Şıkoğlu; Serdar Süleyman Can; Görkem Karakaş Uğurlu; Semra Ulusoy Kaymak; Ali Çayköylü; Oktay Algın; Mary L Phillips; Constance M Moore; Dost Öngür
Journal:  J Affect Disord       Date:  2018-04-04       Impact factor: 4.839

9.  Wireless resonant circuits for the minimally invasive sensing of biophysical processes in magnetic resonance imaging.

Authors:  Aviad Hai; Virginia Ch Spanoudaki; Benjamin B Bartelle; Alan Jasanoff
Journal:  Nat Biomed Eng       Date:  2018-10-22       Impact factor: 25.671

10.  Repeatability and reliability of GABA measurements with magnetic resonance spectroscopy in healthy young adults.

Authors:  Jessica M Duda; Amelia D Moser; Chun S Zuo; Fei Du; Xi Chen; Sarah Perlo; Christine E Richards; Nara Nascimento; Maria Ironside; David J Crowley; Laura M Holsen; Madhusmita Misra; James I Hudson; Jill M Goldstein; Diego A Pizzagalli
Journal:  Magn Reson Med       Date:  2020-11-20       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.