A mid-term analysis suggests ceramic on ceramic hip arthroplasty is durable with minimal wear and low risk of squeak.

Dennis Molloy1, Chris Jack, Christina Esposito, William L Walter.   

Abstract

BACKGROUND: The incidence of hip replacements in the younger patient is ever increasing. With this in mind, improving the longevity of hip arthroplasties is paramount. Alumina ceramic is a promising bearing surface due to its low wear rate and biological inertness.
PURPOSE: This study aims to review our experience with ceramic-on-ceramic total hip arthroplasty, reporting on the need for revision as well as the cause of failure. Our secondary purpose is to review our experience with the phenomenon of squeaking analysing and its effect on clinical outcome with specific emphasis on component positioning. Also reported are the results of our retrieval analysis of explanted components documenting the wear rate and our analysis of strip wear.
METHODS: A consecutive series of 301 primary cementless alumina-on-alumina total hip arthroplasties at a minimum of 10 years follow-up was reviewed. These arthroplasties all had third-generation ceramic-on-ceramic bearings performed through a posterior approach with repair of capsule and external rotators to bone. We analysed hips both clinically and radiographically. Analysis of wear in 62 ceramic bearings was performed using a Roundtest RA300 machine (Mitutoyo; Andover, UK), which has an accuracy of 0.01 μm.
RESULTS: Overall, the survival rate of the implants was 98% at 10 years. No ceramic fractures were encountered in this study. Seventy-four patients reported squeaking hips, and two cases were revised due to squeaking (0.6%). No failures were related to bearing wear.
CONCLUSIONS: We believe that ceramic-on-ceramic is a safe bearing coupling with excellent survivorship at 10 years.

Entities:  

Keywords:  alumina; alumina fracture; ceramic-on-ceramic; review; squeaking

Year:  2012        PMID: 24082875      PMCID: PMC3470676          DOI: 10.1007/s11420-012-9291-y

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  20 in total

1.  Retrieval analysis of squeaking alumina ceramic-on-ceramic bearings.

Authors:  W L Walter; S M Kurtz; C Esposito; W Hozack; K G Holley; J P Garino; M A Tuke
Journal:  J Bone Joint Surg Br       Date:  2011-12

2.  Mittelmeier ceramic-ceramic prosthesis after 10 years.

Authors:  E Garcia-Cimbrelo; J M Martinez-Sayanes; A Minuesa; L Munuera
Journal:  J Arthroplasty       Date:  1996-10       Impact factor: 4.757

3.  Prospective randomized trial comparing alumina ceramic-on-ceramic with ceramic-on-conventional polyethylene bearings in total hip arthroplasty.

Authors:  Peter M Lewis; Ali Al-Belooshi; Michael Olsen; Emil H Schemitch; James P Waddell
Journal:  J Arthroplasty       Date:  2009-02-05       Impact factor: 4.757

4.  Ten-year results after cementless THA with a sandwich-type alumina ceramic bearing.

Authors:  Youn-Soo Park; Se-Jun Park; Seung-Jae Lim
Journal:  Orthopedics       Date:  2010-11-02       Impact factor: 1.390

5.  Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty.

Authors:  Christophe Chevillotte; Vincent Pibarot; Jean-Paul Carret; Jacques Bejui-Hugues; Olivier Guyen
Journal:  Int Orthop       Date:  2010-12-21       Impact factor: 3.075

Review 6.  A literature review of the association between wear rate and osteolysis in total hip arthroplasty.

Authors:  John H Dumbleton; Michael T Manley; Avram A Edidin
Journal:  J Arthroplasty       Date:  2002-08       Impact factor: 4.757

7.  Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces.

Authors:  T R Yoon; S M Rowe; S T Jung; K J Seon; W J Maloney
Journal:  J Bone Joint Surg Am       Date:  1998-10       Impact factor: 5.284

8.  Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation.

Authors:  William L Walter; Gary C O'toole; William K Walter; Andrew Ellis; Bernard A Zicat
Journal:  J Arthroplasty       Date:  2007-03-28       Impact factor: 4.757

9.  Fractures of ceramic bearings: history and present status.

Authors:  Didier Hannouche; Christophe Nich; Pascal Bizot; Alain Meunier; Rémi Nizard; Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2003-12       Impact factor: 4.176

10.  Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty.

Authors:  P J Lusty; C C Tai; R P Sew-Hoy; W L Walter; W K Walter; B A Zicat
Journal:  J Bone Joint Surg Am       Date:  2007-12       Impact factor: 5.284

View more
  2 in total

1.  High failure rate of a new pressfit cup in mid-term follow-up.

Authors:  Steffen Brodt; Georg Matziolis; Christoph Windisch; Andreas Gosse; Matthias Spalteholz; Ralf Herbert Gahr
Journal:  Int Orthop       Date:  2015-07-08       Impact factor: 3.075

2.  Mid-term result of ceramic bearings in total hip arthroplasty.

Authors:  Ismail Remzi Tozun; Vahit Emre Ozden; Goksel Dikmen; Burak Beksac
Journal:  Int Orthop       Date:  2014-06-01       Impact factor: 3.075

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.